Search NASA⌕ Search

Engineering topics

Greaney, Allison

Publications and source records attributed to Greaney, Allison.

Adsorption of molecular iodine and alkyl iodides from spent-nuclear-fuel-reprocessing off-gas using reduced silver mordenite

Radioactive iodine is a hazardous byproduct of spent-nuclear-fuel reprocessing that must be removed from the off-gas stream before it can be discharged. Reduced silver mordenite (Ag 0 Z) is currently the baseline material for iodine capture in the U.S. Although the performance characteristics and capture mechanisms of I 2 and CH 3 I have been established, similar investigations into long-chain organic iodides have yet to be performed. In this study, thin beds of Ag 0 Z were loaded with I 2 , CH 3 I, C 4 H 9 I, and C 12 H 25 I (5 ppm to 50 ppm) carried in a dry air stream at 150°C. The maximum iodine capacity was 105 ± 5 mg I/g Ag 0 Z for all species. Saturated Ag 0 Z samples were characterized using scanning electron microscopy, X-ray fluorescence, X-ray photoelectron spectroscopy, diffuse reflectance UV–visible spectroscopy, pair distribution function analysis, and thermogravimetric analysis. Further, near-complete Ag utilization and similar physical/chemical properties were observed for all samples. Through a comparison with previous studies and an investigation of aged Ag 0 Z, we propose that iodine species react with Ag + at exchange sites, forming α-AgI within the mordenite channels, and with surface Ag 0 nanoparticles, yielding β-/γ-AgI. The available Ag sites in the interior (Ag + ) and exterior (Ag 0 ) of mordenite determine the adsorption capacity since α-AgI formation is limited by the total pore volume. Potential iodine uptake routes were summarized for aging and non-aging environments. A scalable predictive model was implemented for deep-bed iodine removal, and predictions were in good agreement with experimental data. Sensitivity analysis suggests that iodine uptake kinetics is governed by pore diffusion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology Development Roadmap for Volatile Radionuclide Capture and Immobilization

An “Off-Gas and Waste Forms Strategy Workshop” was held in Washington, D.C. on January 31, and February 1, 2023, to review the current state of the art (baseline) technologies for capturing and immobilizing these volatile radionuclides in waste forms (WFs). The discussions in that workshop were used to develop a roadmap for future research and development to mature technologies that are presently not ready for use in a commercial reprocessing facility and develop and demonstrate technologies that provide more safety, more simplicity, or lower costs compared to the current baseline.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Off-Gas Design and Testing from Advanced Chlorination Process

Chlorination of Zr alloy cladding with sulfur-chloride reagents is being considered as a means of separating the main metal from alloying elements, imbedded U, actinides, and fission and activation products to purify the Zr. This would allow the Zr to be disposed of as low-level nuclear waste or possibly be recycled. A multistage process was developed that involves several steps and waste streams. Recycling of sulfur-chloride reagents S 2 Cl 2 and SOCl 2 is planned to minimize the waste stream. The generation of off-gas and entrainment of volatiles is anticipated to be minimized. However, given the complex nature of spent nuclear fuel (SNF), some volatile components will be generated, including the solvents themselves; Cl 2 used for the regeneration of S 2 Cl 2 ; volatile fission product chlorides, such as Sb and 3 H; and chlorinated alloying components, such as Sn, Nb, Fe, and Mo. This report discusses the chemical phenomena that might give rise to volatile species and their planned capture. The volatility of the transition metals will depend on their oxidation state and the compounds that are formed, such as Zr tritide. Loading radionuclides in the process off-gas will depend on the inputs to the process. For instance, processing separated Zr to reduce waste will have a much lower loading of radionuclides than if alternative chlorination were used for decladding SNF. Much of the volatile process streams will be part of the solvent recycling, which may involve online scrubbing. Generally, a caustic scrubber should be included in the off-gas to remove acidic vapors (e.g., Cl 2 , SOCl 2 ). The decontamination procedures for removing these species could involve pretreatment (i.e., heating) options or reduction by contact with H 2 . This report discusses these options along with a framework for testing these alternatives in future experiments. Technologies for off-gas capture will leverage those developed in the Materials Recovery and Waste Forms program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Draft Experimental Plan for Commercial SNF Degradation in Repository Environments with a Focus on Fracture Matrix Degradation

This report documents work performed supporting US Department of Energy (DOE) Nuclear Energy Spent Fuel and Waste Disposition, Spent Fuel and Waste Science and Technology, under work breakdown structure element 1.08.01.03.04, “Inventory and Waste Form Characteristics and Performance.” In particular, this report fulfills the M3 milestone, M3SF-21OR010309072 "Draft Experimental Plan for Commercial SNF Degradation in Repository Environments” as described in work package SF-21OR01030907 "SNF Degradation Testing-ORNL".This experimental plan is a collaboration between ORNL, SNL, ANL, and PNNL. It is intended to support source term model development and spent fuel degradation testing in a range of generic repository conditions. Potential testing and experiments to support validation of the Fuel Matrix Dissolution Model (FMDM) and the overall development/validation of repository source term modeling are discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Behavior of the Mo, Tl, and U isotope systems during differentiation in the Kilauea Iki lava lake

Stable molybdenum (Mo), thallium (Tl), and uranium (U) isotope ratios were determined in a suite of samples from the 1959 Kilauea eruption and from Kilauea Iki lava lake with the aim of understanding the effects of igneous differentiation on these isotope systems. The samples range from olivine cumulate with MgO up to 27% to internal differentiates with MgO less than 3%, representing a tholeiitic differentiation series. Molybdenum, Tl, and U behave incompatibly during differentiation, and Mo and U isotope ratios do not systematically vary amongst the different samples. δ 98 Mo values range from -0.17 to -0.31‰ and δ 238 U values range from -0.20 to -0.38‰. Most individual analyses for both isotope systems overlap within measurement uncertainty (± ~0.7 and ~ 0.6, respectively). Mean δ 98 Mo and δ238U values are -0.22 ± 0.08‰ (2σ) and - 0.29 ± 0.09‰ (2σ), respectively, which overlap with Pacific mid ocean ridge basalt (MORB). In contrast, Tl isotopes show small but resolvable variations, with ε 205 Tl ranging from +1.20 to -1.38. The most negative ε 205 Tl values are confined to some of the lowest [Tl] samples, but the ε 205 Tl values do not otherwise vary smoothly with MgO or [Tl]. Possible mechanisms for thallium isotope fractionation are considered (e.g., degassing, water leaching, sulfide fractionation) but none are found to be satisfactory. Overall, the lack of resolvable variation in the Mo and U isotope systems and the small magnitude of heterogeneity in the Tl isotope system indicate that differentiation in tholeiitic systems is unlikely to be a major contributor to global variation in these isotope systems.

58 GEOSCIENCES↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of HPGe-detected high energy gamma rays toward quantifying neutron emission rates and 234 U enrichment in UF 6 cylinders

This study presents a 234 U enrichment meter that uses high energy gamma and neutron count rate as measured by a portable, high-purity germanium gamma ray detector. Twenty-one 30B cylinders containing UF 6 of varying origin were analyzed with an HPGe detector for high-energy gamma ray and neutron counts. Excellent correlations (R 2 0.95) between various regions of 3.0 MeV gamma rays, neutron count rate, and uranium enrichment were found. These neutron and high-energy gamma data are used to create calibration-dependent enrichment meters for 234 U. The 234 U enrichment calculated from the neutron count rate and 4 – 6 MeV gamma count rate is more accurate than methods that rely on the 120.9 keV peak which is strongly attenuated inside commercial sized UF 6 cylinders. These neutron and high-energy gamma enrichment calculators can also be used to determine a 235 U enrichment, assuming mass-based enrichment from natural uranium, but the results are not as accurate as the traditional 185.7 keV peak enrichment meter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗