Search NASA⌕ Search

Engineering topics

Green, Robert O.

Publications and source records attributed to Green, Robert O..

At least 91 records · Page 5

Instrumentation for Reflectance Spectroscopy and Microspectroscopy with Application to Astrobiology

We present instrument concepts for in-situ reflectance spectroscopy over a spatial resolution range from several meters to tens of micrometers. These have been adapted to the low mass and power requirements of rover or similar platforms. Described are a miniaturized imaging spectrometer for rover mast, a combined mast and arm point spectrometer, and an imaging microspectrometer for the rover arm.

infrared↗

Science and Measurement Requirements for a Plant Physiology and Functional Types Mission: Measuring the Composition, Function and Health of Global Land and Coastal Ocean Ecosystems

This slide presentation reviews the proposed Plant Physiology and Functional Types (PPFT) Mission. The National Academy of Sciences Decadal Survey, placed a critical priority on a Mission to observe distribution and changes in ecosystem functions. The PPFT satellite mission provides the essential measurements needed to assess drivers of change in biodiversity and ecosystem services that affect human welfare. The presentation reviews the science questions that the mission will be designed to answer, the science rationale, the science measurements, the mission concept, the planned instrumentation, the calibration method, and key signal to noise ratios and uniformity requirements.

science measurements↗

Optical Design of a Compact Imaging Spectrometer for Planetary Mineralogy

We present the design of a compact, wide-angle pushbroom imaging spectrometer suitable for exploration of solar system bodies from low orbit. The spectrometer is based on a single detector array with a broadband response that covers the range 400 to 3000 nm and provides a spectral sampling of 10 nm. The telescope has a 24-deg field of view with 600 spatially resolved elements (detector pixels). A specially designed convex diffraction grating permits optimization of the signal-to-noise ratio through the entire spectral band. Tolerances and design parameters permit the achievement of high uniformity of response through field and wavelength. The spectrometer performance is evaluated in terms of predicted spectral and spatial response functions and from the point of view of minimizing their variation through field and wavelength. The design serves as an example for illustrating the design principles specific to this type of system.

space optics↗

Moon Mineral Mapper (M3): A High Uniformity and High Precision Science Imaging Spectrometer in the Solar Reflected Spectrum

The Moon Mineralogy Mapper was selected as a NASA Discovery Mission of Opportunity in February 2005. At the core of this mission is an imaging spectrometer instrument with high spectral-spatial uniformity and high signal-to-noise ratio for the expected illumination conditions. The spectral range of the Moon Mineralogy Mapper is from 430 to 3000 nm with 10 nm spectral sampling. The radiometric range is from 0 to maximum expected radiance with 14 bit sampling. The spatial swath is nominally 40 Ian with 70 m spatial sampling. The Moon Mineralogy Mapper has both a global and target mode of data acquisition. In global spectral and spatial resolution full coverage of the Moon will be acquired. Target mode will be used to examine selected areas a full spectral and spatial resolution. The science objectives and mission and instrument characteristics are presented.

mapping↗

Science Measurement Requirements for Imaging Spectrometers from Airborne to Spaceborne

This slide presentation reviews the objectives of the work to create imaging spectrometers. The science objectives are to remotely determine the properties of the surface and atmosphere (physics, chemistry and biology) revealed by the interaction of electromagnetic energy with matter via spectroscopy. It presents a review the understanding of spectral, radiometric and spatial science measurement requirements for imaging spectrometers based upon science research results from past and current airborne and spaceborne instruments. It also examines the future requirements that will enable the next level of imaging spectroscopy science.

radiometric requirements↗

Assessment of AVIRIS Laboratory and In-Flight Uniformity

This viewgraph presentation describes a uniform system for AVIRIS radiometry. The contents include: 1) What is Uniformity? 2) Spectral Cross-Track Uniformity; 3) Hyperion Example; 4) AVIRIS Example; and 5) Spectral-IFOV Uniformity.

AVIRIS↗

High- and low-altitude AVIRIS observations of nocturnal lighting

Elvidge et al. (1997) developed methods to locate and define the spatial extent of nocturnal lighting across large land areas using low-light imaging data from the Defense Meteorological Satellite Program (DMSP) Operational Linescan System (OLS). This sensor has a unique capability to detect low levels of visible - near infrared radiance at night (Figure 1). The primary function of the DMSP-OLS is to provide global imagery of cloud cover. At night the observed visible - near infrared (VNR) radiance is intensified, for the purpose of cloud detection using moonlight. In addition to moonlit clouds, the light intensification makes it possible to detect VNIR emissions emanating from the earth's surface, from cities, towns, industrial sites, gas flares, and ephemeral events such as fires. In the latter part of this decade NOAA, NASA and DoD plan to fly a new sensor (Visible Infrared Imaging Radiometer Suite - VIJRS) which will continue the record of low-light imaging earth observations, with improved spatial and radiometric properties over the OLS.

Green, Robert O.↗

An improved data structure for AVIRIS-type imaging spectrometer measurements

Imaging spectrometers, such as the Airborne Visible/Infrared Imaging (AVIRIS), measure spectra in the region from 400 to 2500 nm at nominally 10-nrn sampling. This gives approximately 200 continuous spectral channels of data for every spatial element measured. These spectroscopic measurements are used to determine the composition and infer processes of the Earth system through spectroscopy analysis. Spectroscopic analysis is based on the physics, chemistry, and biology revealed through the interaction of energy with matter recorded in each measured spectrum

Perez, Rosa M.↗

The Flora Mission for Ecosystem Composition, Disturbance and Productivity

Global land use and climate variability alter ecosystem conditions - including structure, function, and biological diversity - at a pace that requires unambiguous observations from satellite vantage points. Current global measurements are limited to general land cover, some disturbances, vegetation leaf area index, and canopy energy absorption. Flora is a pathfinding mission that provides new measurements of ecosystem structure, function, and diversity to understand the spatial and temporal dynamics of human and natural disturbances, and the biogeochemical and physiological responses of ecosystems to disturbance. The mission relies upon high-fidelity imaging spectroscopy to deliver full optical spectrum measurements (400-2500 nm) of the global land surface on a monthly time step at 45 meter spatial resolution for three years. The Flora measurement objectives are: (i) fractional cover of biological materials, (ii) canopy water content, (iii) vegetation pigments and light-use efficiency, (iv) plant functional types, (v) fire fuel load and fuel moisture content, and (vi) disturbance occurrence, type and intensity. These measurements are made using a multi-parameter, spectroscopic analysis approach afforded by observation of the full optical spectrum. Combining these measurements, along with additional observations from multispectral sensors, Flora will far advance global studies and models of ecosystem dynamics and change.

Asner, Gregory P.↗

Assessment of AVIRIS Laboratory and In-Flight Uniformity

An assessment of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) laboratory and in-flight uniformity is presented in this Slide presentation. The ideal uniform system is described, being a system where every spectrum is intercomparable to every other spectrum. Two types of failures to achieve this uniformity are described. Graphs showing measured spectral upwelling radiance, the expanded spectral convolution, the radiometric error from spectral error, the results from the hyperion Arizaro calibration experiment and a AVIRIS cross-track uniformity are among those presented. The reasons why uniformity matters are presented.

imaging spectroscopy↗

Design of a Pushbroom Imaging Spectrometer that Exceeds AVIRIS Performance

This slide presentation reviews the design of a Pushbroom Imaging Spectrometer, that will exceed the performance of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). The approach for the AVIRIS-II instrument is reviewed as are the specifications for the new spectrometer. Even though the pushbroom spectrometer is inherently non-uniform, the design of the AVIRIS-II provides for uniformity. Spot diagrams at the slit and at the detector inside the 27micron box are presented. A few of the challenges in the mechanical design and the making of the slit are discussed. The specifications of the 6604A detector array are reviewed. Slides showing the expected Signal to Noise Ratio performance are presented.

Airborne Visible/Infrared Imaging Spectrometer (AV↗

Radiometric Performance Model for AVIRIS

This slide presentation reviews the radiometric performance model for Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This model allows for an estimation of the signal throughput and noise properties of AVIRIS for the components. This understanding can point to areas for improvements of the components.. The signal to noise ratio properties may be estimated. An accurate radiometric performance model is essential for the use of existing instruments and the design of new instruments. Included in the presentation is a design view and a picture of the AVIRIS instrument. There is discussion of the signal, the signal area solid angle product, aspects of area solid angle time, the idealized radiometer photon calculation and noise both instrument read and photon counting noise. Graphs of signal throughput efficiency, input radiance, photons at the detector, signal e-, noise e- and the signal to noise ratio are presented.

imaging spectroscopy↗

Proceedings of the 12th JPL Airborne Earth Science Workshop

Participants at the 12th Airborne Earth Science Workshop reported science research and applications results with spectral images measured by the NASA Airborne Invisible/lnfrared Imaging Spectrometer (AVIRIS). The workshop was held in Pasadena, California, from February, 2003.

Green, Robert O.↗

Proceedings of the 11th JPL Airborne Earth Science Workshop

This publication contains the proceedings of the JPL Airborne Earth Science Workshop forum held to report science research and applications results with spectral images measured by the NASA Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). These papers were presented at the Jet Propulsion Laboratory from March 5-8, 2001. Electronic versions of these papers may be found at the A VIRIS Web http://popo.jpl.nasa.gov/pub/docs/workshops/aviris.proceedings.html

Airborne Visible/Infrared Imaging Spectrometer (AV↗

Proceedings of the Tenth JPL Airborne Earth Science Workshop

This publication contains the proceedings of the AVIRIS Earth Science and Applications Workshop - a forum held to report science research and applications results with spectral images measured by the NASA Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). These papers were presented at the Jet Propulsion Laboratory on February 27 and 28 and March 1 and 2, 2001.

Green, Robert O.↗