Search NASA⌕ Search

Engineering topics

Greene, G. L.

Publications and source records attributed to Greene, G. L..

Unconventional isoquinoline-based SERMs elicit fulvestrant-like transcriptional programs in ER+ breast cancer cells

Estrogen receptor alpha (ERα) is a ligand-dependent master transcriptional regulator and key driver of breast cancer pathology. Small molecule hormones and competitive antagonists favor unique ERα conformational ensembles that elicit ligand-specific transcriptional programs in breast cancer and other hormone-responsive tissues. By affecting disparate ligand binding domain structural features, unconventional ligand scaffolds can redirect ERα genomic binding patterns to engage novel therapeutic transcriptional programs. To improve our understanding of these ERα structure-transcriptional relationships, we develop a series of chemically unconventional antagonists based on the antiestrogens elacestrant and lasofoxifene. High-resolution x-ray co-crystal structures show that these molecules affect both classical and unique structural motifs within the ERα ligand binding pocket. They show moderately reduced antagonistic potencies on ERα genomic activities but are effective anti-proliferative agents in luminal breast cancer cells. Interestingly, they favor a 4-hydroxytamoxifen-like accumulation of ERα in breast cancer cells but lack uterotrophic activities in an endometrial cell line. Importantly, RNA sequencing shows that the lead molecules engage transcriptional pathways similar to the selective estrogen receptor degrader fulvestrant. This advance shows that fulvestrant-like genomic activities can be achieved without affecting ERα accumulation in breast cancer cells.

60 APPLIED LIFE SCIENCES↗

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the HIBEAM/NNBAR experiment at the European Spallation Source

The violation of baryon number, , is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the Universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron–antineutron oscillation () via mixing, neutron–antineutron oscillation via regeneration from a sterile neutron state (), and neutron disappearance (n → n′); the effective process of neutron regeneration () is also possible. The program can be used to discover and characterize mixing in the neutron, antineutron and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis and the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Precision Measurement of the Parity Violating Asymmetry in Cold Neutron Capture on 3 He

We report the first precision measurement of the parity-violating asymmetry in the direction of proton momentum with respect to the neutron spin, in the reaction 3 He(n,p) 3 H, using the capture of polarized cold neutrons in an unpolarized active 3 He target. The asymmetry is a result of the weak interaction between nucleons, which remains one of the least well-understood aspects of electroweak theory. The measurement provides an important benchmark for modern effective field theory and potential model calculations. Measurements like this are necessary to determine the spin-isospin structure of the hadronic weak interaction. Our asymmetry result is A PV =[1.55±0.97(stat)±0.24(sys)]×10 -8 , which has the smallest uncertainty of any hadronic parity-violating asymmetry measurement so far.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Observation of 𝑃-odd 𝛾 Asymmetry in Polarized Neutron Capture on Hydrogen

Here, we report the first observation of the parity-violating gamma-ray asymmetry 𝐴$^{𝑛⁢𝑝}_{𝛾}$ in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. 𝐴$^{𝑛⁢𝑝}_{𝛾}$ isolates the Δ⁢𝐼 =1, 3 𝑆 1 → 3 𝑃 1 component of the weak nucleon-nucleon interaction, which is dominated by pion exchange and can be directly related to a single coupling constant in either the DDH meson exchange model or pionless effective field theory. We measured 𝐴$^{𝑛⁢𝑝}_{𝛾}$=[−3.0±1.4⁢(stat)±0.2⁢(syst)]×10 −8 , which implies a DDH weak 𝜋⁢𝑁⁢𝑁 coupling of ℎ$^1_𝜋$=[2.6±1.2⁢(stat)±0.2⁢(syst)]×10 −7 and a pionless EFT constant of 𝐶 3 𝑆 1 → 3 𝑃 1 /𝐶 0 =[−7.4±3.5⁢(stat)±0.5⁢(syst)]×10 −11 MeV −1 . We describe the experiment, data analysis, systematic uncertainties, and implications of the result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo calculation and verification of the geometrical factors for the NPDGamma experiment

The NPDGamma experiment measures the parity-violating asymmetry in gamma-ray emission in the capture of polarized neutrons on liquid parahydrogen. The sensitivity to the asymmetry for each detector in the array is used as a parameter in the extraction of the physics asymmetry from the measured data. The detector array is approximately cylindrically symmetric around the target and a step-wise sinusoidal function has been used for the sensitivity in the previous iteration of the NPDGamma experiment, but deviations from cylindrical symmetry necessitate the use of a Monte Carlo model to determine corrections to the geometrical factors. For the calculations, source code modifications to MCNPX were done in order to calculate the sensitivity of each cesium iodide detector to the physics asymmetry. We describe the MCNPX model and results from calculations and how the results are validated through measurement of the parity violating asymmetry of gamma-rays from neutron capture on chlorine.

Grammer, K. B.↗

Specific stereochemistry of OP-1074 disrupts estrogen receptor alpha helix 12 and confers pure antiestrogenic activity

Complex tissue-specific and cell-specific signaling by the estrogen receptor (ER) frequently leads to the development of resistance to endocrine therapy for breast cancer. Pure ER antagonists, which completely lack tissue-specific agonist activity, hold promise for preventing and treating endocrine resistance, however an absence of structural information hinders the development of novel candidates. Here we synthesize a small panel of benzopyrans with variable side chains to identify pure antiestrogens in a uterotrophic assay. We identify OP-1074 as a pure antiestrogen and a selective ER degrader (PA-SERD) that is efficacious in shrinking tumors in a tamoxifen-resistant xenograft model. Biochemical and crystal structure analyses reveal a structure activity relationship implicating the importance of a stereospecific methyl on the pyrrolidine side chain of OP-1074, particularly on helix 12.

60 APPLIED LIFE SCIENCES↗

Precision determination of absolute neutron flux

A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using an alpha–gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10 B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478 keV gamma rays from neutron capture on 10 B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024%. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6 Li was determined to an overall uncertainty of 0.058%. We discuss the principle of the alpha–gamma method and present details of how the measurement was performed including the systematic effects. We further describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the absolute neutron beam polarization from a supermirror polarizer and the absolute efficiency of a neutron spin rotator for the NPDGamma experiment using a polarized 3 He neutron spin-filter

Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of ~10 9 neutrons per second per cm 2 and a cross sectional area of 10 x 12 cm 2 . The polarization of this neutron beam and the efficiency of a RF neutron spin rotator installed downstream on this beam were measured by neutron transmission through a polarized 3 He neutron spin-filter. The pulsed nature of the SNS enabled us to employ an absolute measurement technique for both quantities which does not depend on accurate knowledge of the phase space of the neutron beam or the 3 He polarization in the spin filter and is therefore of interest for any experiments on slow neutron beams from pulsed neutron sources which require knowledge of the absolute value of the neutron polarization. The polarization and spin-reversal efficiency measured were done for the NPDGamma experiment, which measures the parity violating γ-ray angular distribution asymmetry with respect to the neutron spin direction in the capture of polarized neutrons on protons. Finally, the experimental technique, results, systematic effects, and applications to neutron capture targets are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron decay correlations in the Nab experiment

The Nab experiment will measure the correlation a between the momenta of the beta particle and antineutrino in neutron decay as well as the Fierz term b which distorts the beta spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the NPDGamma experiment

We report that the NPDGamma experiment measures the parity-violating (PV) gamma asymmetry from polarized cold neutrons captured on protons at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The (PV) neutron spin asymmetry A γ of photons from polarized cold neutron capture on protons is proportional to the ΔI=1 long range weak meson coupling h$1\atop{π}$ between nucleons in the hadronic weak interaction (HWI). Liquid para-hydrogen production data taking concluded in April 2014 and once the background aluminum asymmetry measurements are complete, the PV asymmetry A γ can be extracted. Finally, preliminary results of the analysis of A γ are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the scattering cross section of slow neutrons on liquid parahydrogen from neutron transmission

Liquid hydrogen is a dense Bose fluid whose equilibrium properties are both calculable from first principles using various theoretical approaches and of interest for the understanding of a wide range of questions in many-body physics. Unfortunately, the pair correlation function g(r) inferred from neutron scattering measurements of the differential cross section dσ/dΩ from different measurements reported in the literature are inconsistent. We have measured the energy dependence of the total cross section and the scattering cross section for slow neutrons with energies between 0.43 and 16.1 meV on liquid hydrogen at 15.6 K (which is dominated by the parahydrogen component) using neutron transmission measurements on the hydrogen target of the NPDGamma collaboration at the Spallation Neutron Source at Oak Ridge National Laboratory. The relationship between the neutron transmission measurement we perform and the total cross section is unambiguous, and the energy range accesses length scales where the pair correlation function is rapidly varying. At 1 meV our measurement is a factor of 3 below the data from previous work. We present evidence that these previous measurements of the hydrogen cross section, which assumed that the equilibrium value for the ratio of orthohydrogen and parahydrogen has been reached in the target liquid, were in fact contaminated with an extra nonequilibrium component of orthohydrogen. Liquid parahydrogen is also a widely used neutron moderator medium, and an accurate knowledge of its slow neutron cross section is essential for the design and optimization of intense slow neutron sources. Furthermore, we describe our measurements and compare them with previous work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamental neutron physics beamline at the spallation neutron source at ORNL

In this paper, we describe the Fundamental Neutron Physics Beamline (FnPB) facility located at the Spallation Neutron Source at Oak Ridge National Laboratory. The FnPB was designed for the conduct of experiments that investigate scientific issues in nuclear physics, particle physics, astrophysics and cosmology using a pulsed slow neutron beam. Finally, we present a detailed description of the design philosophy, beamline components, and measured fluxes of the polychromatic and monochromatic beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Technique for Determining Neutron Beam Fluence to 0.01% Uncertainty

The achievable uncertainty in neutron lifetime measurements using the beam technique has been limited by the uncertainty in the determination of the neutron density in the decay volume. In the Sussex-ILL-NIST series of beam lifetime experiments, the density was determined with a neutron fluence mon itor that detected the charged particle products from neutron absorption in a thin layer of 6Li or lOB. In each of the experiments, the absolute detection efficiency of the neutron monitor was determined from the measured density of the neutron absorber, the thermal neutron cross section for the absorbing ma terial, and the solid angle of the charged particle detectors. The efficiency of the neutron monitor used in the most recent beam lifetime experiment has since been measured directly by operating it on a monochromatic neutron beam in which the total neutron rate is determined with a totally absorbing neutron detector. The absolute nature of this technique does not rely on any knowl edge of neutron absorption cross sections or a measurement of the density of the neutron absorbing deposit. This technique has been used to measure the neutron monitor efficiency to 0.06% uncertainty. VVe show that a new monitor and absolute neutron detector employing the same technique would be capable of achieving determining neutron fluence to an uncertainty of 0.01%.

neutron fluence↗

Neutron Beta Decay Studies with Nab

Precision measurements in neutron beta decay serve to determine the coupling constants of beta decay and allow for several stringent tests of the standard model. This paper discusses the design and the expected performance of the Nab spectrometer.

neutron beta decay↗

Ultracold Neutrons - Quantum Bouncing Ball Resonates

Spectroscopic techniques typically probe the interaction between matter and electromagnetic fields. An experiment now demonstrates that transitions between quantum states of neutrons can be brought about by mechanically vibrating a mirror, an approach that may lead to sensitive tests of gravity laws.

Greene, G. L.↗