Search NASA⌕ Search

Engineering topics

Greene, Travis M.

Publications and source records attributed to Greene, Travis M..

Verified, Archived, Library of Inputs and Data (VALID) Supporting Files

This dataset contains input, output, and sensitivity data files for computational simulations with the SCALE code system as part of the Verified, Archived Library of Inputs and Data (VALID). The simulations cover critical benchmark experiments from the International Criticality Safety Benchmark Evaluation Project. The files are to be housed in a public directory for distribution. The information contained in the files have been approved for release by the Organisation for Economic Co-operation and Development Nuclear Energy Agency (NEA). Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases.

keff↗

Procedure for the Computational Models created for the DOE/NRC Collaboration for Criticality Safety Support for Commercial-Scale HALEU Fuel Cycles Project (DNCSH)

This procedure outlines the application models developed as part of the US Department of Energy (DOE) and Nuclear Regulatory Commission (NRC) collaboration for criticality safety support for commercial scale HALEU fuel cycle and transportation (DNCSH) project, an effort authorized by the US Congress. The project is a joint effort among the DOE, NRC, numerous national laboratories, and private enterprises with project management from Oak Ridge National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sum-of-Fractions Methodology for Actinides in Water- and Polyethylene-Moderated and -Reflected Systems

Sum-of-fractions is a method intended to make sure a subcritical margin for aqueous solutions and slurries of fissionable isotopes exists. The method indicates that a system is subcritical if the sum of the ratios of the mass of each isotope (in a mixture) to its individual minimum subcritical mass limit is less than or equal to one. Historically, the basis of the sum-of-fractions has been derived from allowances given in the American National Standards Institute (ANSI)/ American Nuclear Society (ANS)-8.15-1981. However, the allowance was removed in ANSI/ANS-8.15-2014 due to a lack of technical basis. A methodology was developed to assess the validity of using the sum-of-fractions for water- or polyethylene-moderated systems for the following nuclides: 232 U, 233 U, 234 U, 235 U, 237 Np, 236 Pu, 238 Pu, 239 Pu, 240 Pu, 241 Pu, 242 Pu, 241 Am, 242 m Am, 243 Am, 242 Cm, 243 Cm, 244 Cm, 245 Cm, 246 Cm, 247 Cm, 249 Cf, and 251 Cf. The methodology uses available benchmark data for mixtures of 233 U, 235 U, and 239 Pu to establish the calculational margin, and a mass limit reduction to establish the margin of subcriticality. Water- or polyethylene-moderated and -reflected mixtures containing the nuclides are evaluated with the code system, SCALE 6.2.4. Including the calculational margin, subcritical mass limits for each nuclide were computed for optimally water- or polyethylene-moderated and fully reflected systems. These masses were used to create nuclide mixtures in which the sum of the mass to subcritical mass limit ratios is one. The various nuclide mixtures were modeled over a range of moderation and demonstrate the keff does not exceed the calculational margin. For additional assurance of subcriticality, a significant mass reduction is applied to each computed minimum critical mass of the nuclides without adequate benchmark data consistent with the method in ANSI/ANS-8.15-2014.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of the Sum-of-Fractions Methodology for Water and Polyethylene Moderated Systems

Sum-of-Fractions is a method intended to assure a subcritical margin for aqueous solutions and slurries of fissionable isotopes. The method indicates that a system is subcritical if the sum of the ratios of the mass of each isotope in a mixture to its individual minimum subcritical mass limit is less than or equal to one. The basis of the Sum-of Fractions has historically been derived from allowances given in ANSI/ANS-8.15-1981. However, the allowance was removed in ANSI/ANS-8.15-2014 due to a lack of technical basis. A methodology was developed to assess the validity of using the Sum-of-Fractions for water or polyethylene moderated systems for the following nuclides: 232 U, 233 U, 234 U, 235 U, 237 Np, 236 Pu, 238 Pu, 239 Pu, 240 Pu, 241 Pu, 242 Pu, 241 Am, 242 mAm, 243 Am, 242 Cm, 243 Cm, 244 Cm, 245 Cm, 246 Cm, 247 Cm, 249 Cf, and 251 Cf. The methodology uses available benchmark data for mixtures of 233 U, 235 U, and 239 Pu to establish the calculational margin, and a mass limit reduction to establish the margin of subcriticality. Water or polyethylene moderated and reflected mixtures containing the nuclides are evaluated with SCALE 6.2.4. Including the calculational margin, subcritical mass limits for each nuclide were computed for optimally water or polyethylene moderated and fully reflected systems. These masses were used to create nuclide mixtures in which the sum of the mass to subcritical mass limit ratios is one. The various nuclide mixtures were modeled over a range of moderation and demonstrate the k eff does not exceed the calculational margin. For additional assurance of subcriticality, a significant mass reduction is applied to each computed minimum critical mass of the nuclides without adequate benchmark data consistent with the method in ANSI/ANS-8.15-2014.

07 ISOTOPE AND RADIATION SOURCES↗

Deterministic-Monte Carlo Hybrid Methods for Eigenvalue Sensitivity Coefficient Calculations

The TSUNAMI suite within the SCALE code package includes several methods for generating sensitivity data, including multigroup (MG) and continuous-energy (CE) capabilities. For generating sensitivities with CE data, three methods are available in SCALE 6.3.0: (1) the iterated fission probability (IFP) method with the KENO Monte Carlo transport solver, (2) IFP with the Shift Monte Carlo transport solver, and (3) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance Characterization (CLUTCH) with the KENO Monte Carlo transport solver. Currently, it is difficult to generate accurate sensitivities with large reflectors when using the CLUTCH method, specifically with fissionable and hydrogenous materials. To address this issue, the work presented herein examines a methodology to calculate the adjoint flux externally with the 3D deterministic SN transport code DENOVO in SCALE; the result is then read directly into the CLUTCH-TSUNAMI sequence. This hybridization method replaces the Monte Carlo F*(r) calculation in CLUTCH while still utilizing the forward calculation. The critical benchmark HEU-MET-FAST-028-001 is used to generate sensitivities based on the inability of CLUTCH to generate accurate sensitivities. Results from the hybrid method appear to generate sensitivity values that are in excellent agreement with direct perturbations. Although further testing is needed, the method provides promising results for the development and utility of a hybrid method for use in TSUNAMI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validating Mixtures of 233 U, 235 U, and 239 Pu for the Sum-of-Fractions Method

The Sum-of-Fractions method is a technique used to assure that homogeneous mixtures of fissile and fissionable isotopes are below a minimum margin of k eff or reactivity. Current work by Pacific Northwest National Laboratory examines different mixtures of 233 U, 235 U, and 239 Pu to determine critical mass limits for mixtures of transuranic actinides lacking a validation basis. To provide a validation basis for these limits, the work presented here describes the results of a sensitivity and uncertainty analysis of various mixtures of these isotopes in various concentrations moderated and reflected by light water and polyethylene. The TSUNAMI-1D sequence in the SCALE code system was used to generate sensitivity coefficients for three different concentrations of mixtures of 233 U, 235 U, and 239 Pu. The TSUNAMI-IP sequence was then used for similarity assessment (c k ) with critical benchmark experiment sensitivity data files (SDFs) from the Oak Ridge National Laboratory Verified, Archived Library of Inputs and Data and the Nuclear Energy Agency SDF database. The VADER sequence in SCALE was used for statistical testing and to generate upper subcritical limits from the data to develop a basis for validating critical mass limits.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of Thermal Scattering Law on Similarity Assessment in Light-Water or Polyethylene-Moderated Systems

A collaborative effort between Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) is underway to provide a technical basis and methodology for the criticality safety community to use the sum of fractions (SoF) method for generating limits for mixtures of “selected actinide nuclides” included in the ANSI/ANS 8.15 standard. The PNNL scope in this project is to define a range of mixtures of 233 U, 235 U, and 239 Pu moderated with either light water or polyethylene and to examine the critical masses for these mixtures. The ORNL scope is primarily to provide validation support for these studies. More complete discussion of the project and its validation aspects will be presented at the upcoming International Conference on Nuclear Criticality Safety (ICNC) this Fall in Sendai, Japan. Clear differences in benchmark similarity to application systems as assessed by the integral parameter ck are noted in the validation studies performed as part of this project as a function of moderator. The c k value is a correlation coefficient that represents that amount of shared uncertainty in k eff due to cross sections between two systems. Individual nuclide-reaction contributions between the two systems can be simply summed to arrive at the total c k value. Specifically, the c k values for light-water–moderated solution experiments are higher for a water-moderated application than for a polyethylene-moderated application. This result is neither totally unexpected nor surprising, but the magnitude of the difference was difficult to anticipate. The TSUNAMI sequence, in the SCALE 6.2.4 code package developed by ORNL, was used to generate eigenvalues and reactivity effects with perturbation-theory based approach through sensitivity coefficients for all nuclides in the system with all reactions and energy groups. The TSUNAMI-Indices and Parameters (IP) sequence then uses the sensitivity data generated through TSUNAMI to generate relational parameters (i.e., c k ) to determine the degree of similarity between systems. One detail of the SCALE material and data implementation must be discussed at this point. Several thermal scattering laws (TSLs) are available for 1 H. SCALE uses a different nuclide ID number for each TSL; essentially, each version of 1 H is treated as a unique nuclide. For example, 1 H bound in water ( 1 H-H2O) is assigned the nuclide ID 1001, whereas 1 H bound in polyethylene (h-poly) is assigned the nuclide ID 9001001. The same cross section data are used for all reactions in 1 H, regardless of TSL, except for scattering below the TSL cutoff energy. TSUNAMI-IP treats different nuclide IDs as different nuclides; thus, no uncertainty is shared between 1 H-H2O and h-poly, despite much of the same data, including covariance data, being used for both nuclides. This presents a question: how much of the difference in assessed similarity between water- and polyethylene-moderated systems is due to the moderators, and how much is caused by the treatment of 1 H-H2O and h poly with cross section and covariance data. The extended edits generated by TSUANMI-IP allow for an investigation of this issue specifically, as well as a demonstration of the general techniques available within TSUNAMI to understand the results of the similarity assessment. This paper presents and analyzes the similarity assessment of both water- and polyethylene-moderated systems for a single benchmark: PST-002-001.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗