(U) PRAD0697 & PRAD0698: Complex Loading of CeO₂ Powder

Cerium(IV) oxide (CeO₂) powder is shock compressed using the Precision High Energy-density Liner Implosion eXperiment (PHELIX) platform. Experimental results are compared against several modeling approaches. Compaction behavior is best captured with a P-∝ model, which calculates CeO₂ powder bulk densities within 80-99% of experimental values but overpredicts densi cation at the cylindrical target's outer radius and center by up to 20%. Preliminary calculations suggest that accuracy could be increased with the inclusion of a coupled strength model. Several common computational modeling approaches for the shock compression response of granular materials and the magnetohydrodynamic (MHD) force upon the impactor/liner in pulsed power compression experiments are investigated and analyzed for their validity. The Bi-linear Ramp, P-∝ PACXP, and P-∝ Menikoff-Kober continuum compaction models are calibrated to planar impact Hugoniot data for CeO₂ powder and used to predict the powder's shock compaction response under non-planar shock wave compression. MHD calculations of the PHELIX pulsed power driver are performed using an idealized resistor-inductor-capacitor (RLC) circuit calibrated to previous experiments. All simulations are performed using the LANL code FLAG. Two validation experiments are computationally designed using the calibrated compaction and circuit models, executed using the PHELIX platform on CeO₂ targets with initial porous densities of 3.95 and 4.03 g/cm³, measured with proton radiography, and analyzed against the model predictions. The two P-∝ models more accurately describe CeO₂ powder densi cation than the Bi-linear Ramp model. However, the two P-∝ models overpredict bulk density of the shock compressed CeO₂ powder by up to 20% when the appropriate impact velocities are applied. MHD calculations for both validation experiments underpredict liner impact velocities by 4-11% when using the idealized RLC circuit model calibrated to previous experiments. Compensating underpredictions of impact velocity and overpredictions of powder densication lead to a false accuracy in pre-shot calculations compared to experimental data. To improve correlation between simulations and experiments, the following improvements are suggested: 1. A coupled strength model for CeO₂ powder that updates strength as a function of porosity and applied stress. 2. An improved MHD circuit model that more accurately captures the PHELIX machine.

36 MATERIALS SCIENCE↗

(U) Pre-shot Report: Complex Loading of CeO 2 Powder

A cylindrically converging shock compaction experiment is designed utilizing the Precision High Energy-density Liner Implosion eXperiment (PHELIX) platform to dynamically load CeO 2 powder. Parametric analyses investigating the effect of PHELIX cassette geometry, PHELIX total capacitor charge, and powder compaction model on the predicted shocked density profile of the CeO 2 powder are performed using the LANL codes FLAG and RAVEN. One PHELIX cassette geometry is designed to be used in two compaction experiments using PHELIX capacitor charges of 85 and 90 kV. Predictions of the shocked density profile in the CeO 2 powder are presented for each experimental configuration using both the Ramp and P-α compaction models. The two compaction models predict shocked density profiles in the CeO 2 powder that are significantly different and should be distinguishable using proton radiography as a diagnostic.

36 MATERIALS SCIENCE↗

Fielding the LANL Gas Cherenkov Detector (GCD-3) at the National Ignition Facility: The engineering challenges of designing, analyzing, fabricating, testing, and commissioning the next-generation GCD detector and WellDIM3.9m insertion manipulator for use at NIF

We report that fielding the LANL third-generation Gas Cherenkov Detector (GCD-3) at the National Ignition Facility (NIF) revealed an array of complex engineering challenges. Fielding the GCD-3 Detector in a 3.9 meter re-entrant Well on the NIF Target Chamber required the development of a specialized detector deployment system named the WellDIM3.9m Diagnostic Manipulator (WellDIM). The most stringent design requirement entailed a no-load/no-contact condition with the Well, which dictated that all seismic loads be transferred to the Target Chamber port flange. The WellDIM transports the GCD-3 into the Well at a distance of 3.9m from Target Chamber Center. Finally, the GCD-3 Detector, outfitted with additional shielding to mitigate higher NIF backgrounds, will serve as a prototype for the future, heavily shielded “Super-GCD”.

42 ENGINEERING↗

PHELIX Crenulation 2 and 3 Flash Report

This report documents the execution of the PHELIX driven Crenulation 2 and 3 at LANSCE proton radiography experiments in FY17 in support of the LANL Science Campaign-1 L2 Milestone (#5721). It should be noted that LANL Science Campaign 3 also supports the PHELIX at pRad efforts.

36 MATERIALS SCIENCE↗

Design and fabrication of a window for the gas Cherenkov detector 3

The gas Cherenkov detector 3 was designed at Los Alamos National Laboratory for use in inertial confinement fusion experiments at both the Omega Laser Facility and the National Ignition Facility. This instrument uses a low-Z gamma-to-electron convertor plate and high pressure gas to convert MeV gammas into UV/visible Cherenkov photons for fast optical detection. This is a follow-on diagnostic from previous versions, with two notable differences: the pressure of the gas is four times higher, and it allows the use of fluorinated gas, requiring metal seals. These changes force significant changes in the window component, having a unique set of requirements and footprint limitations. The selected solution for this component, a sapphire window brazed into a stainless steel flange housing, is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Generation Gamma-Ray Cherenkov Detectors for the National Ignition Facility

The newest generation of Gas Cherenkov Detector (GCD-3) employed in Inertial Confinement Fusion experiments at the Omega Laser Facility has provided improved performance over previous generations. Comparison of reaction histories measured using two different deuterium-tritium fusion products, namely gamma rays using GCD and neutrons using Neutron Temporal Diagnostic (NTD), have provided added credibility to both techniques. GCD-3 is now being brought to the National Ignition Facility (NIF) to supplement the existing Gamma Reaction History (GRH-6m) located 6 m from target chamber center (TCC). Initially it will be located in a reentrant well located 3.9 m from TCC. Data from GCD-3 will inform the design of a heavily-shielded “Super” GCD to be located as close as 20 cm from TCC. In conclusion, it will also provide a test-bed for faster optical detectors, potentially lowering the temporal resolution from the current ~100 ps state-of-the-art photomultiplier tubes (PMT) to ~10 ps Pulse Dilation PMT technology currently under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crenulation-­1 Flash Report

We briefly report on the first of PHELIX driven Crenulation experiments diagnosed with proton radiography. PHELIX is a 300 kJ capacitor bank located at the LANL LANSCE pRad facility. It is capable of delivering a 4 MA, 10 us current pulse to a low inductance cylindrical load. Using a magnetically driven cylindrical liner, we have shocked a concentric tin cylindrical shell to melt-on-release and compared to theory and calculations. The inner surface of the tin cylinder has three sectors of single-mode perturbations, which are subject to Richtmyer-Meshkov Instability (RMI). Recent theoretical work on the EOS of tin has modified both the Hugoniot and the isentropes for release into various states in tabular data. The new multiphase EOS for tin, SESAME 2161, includes the beta and gamma solid phases as well as a liquid phase. It predicts a lower pressure boundary for release to pure solid (~20 GPa) and a higher pressure boundary for release to pure liquid (~35 GPa) than the existing SESAME 2160 table.