Search NASA⌕ Search

Engineering topics

Grigg, Reid

Publications and source records attributed to Grigg, Reid.

Mechanisms of Waterflood Inefficiency: Analysis of Geological, Petrophysical and Reservoir History, a Field Case Study of FWU (East Section)

The petroleum reservoir represents a complex heterogeneous system that requires thorough characterization prior to the implementation of any incremental recovery technique. One of the most commonly utilized and successful secondary recovery techniques is waterflooding. However, a lack of sufficient investigation into the inherent behavior and characteristics of the reservoir formation in situ can result in failure or suboptimal performance of waterflood operations. Therefore, a comprehensive understanding of the geological history, static and dynamic reservoir characteristics, and petrophysical data is essential for analyzing the mechanisms and causes of waterflood inefficiency and failure. In this study, waterflood inefficiency was observed in the Morrow B reservoir located in the Farnsworth Unit, situated in the northwestern shelf of the Anadarko Basin, Texas. To assess the potential mechanisms behind the inefficiency of waterflooding in the east half, geological, petrophysical, and reservoir engineering data, along with historical information, were integrated, reviewed, and analyzed. The integration and analysis of these datasets revealed that several factors contributed to the waterflood inefficiency. Firstly, the presence of abundant dispersed authigenic clays within the reservoir, worsened by low reservoir quality and high heterogeneity, led to unfavorable conditions for waterflood operations. The use of freshwater for flooding exacerbated the adverse effects of sensitive and migratory clays, further hampering the effectiveness of the waterflood. In addition to these factors, several reservoir engineering issues played a significant role in the inefficiency of waterflooding. These issues included inadequate perforation strategies due to the absence of detailed hydraulic flow units (HFUs) and rock typing, random placement of injectors, and uncontrolled injected fresh water. These external controlling parameters further contributed to the overall inefficiencies observed during waterflood operations in the east half of the reservoir. A detailed understanding of the mechanistic factors of inefficient waterflood operation will provide adequate insights into the development of the improved recovery technique for the field.

Morgan, Anthony (ORCID:0000000211519153)↗

Techno-economic life cycle assessment of CO 2 -EOR operations towards net negative emissions at farnsworth field unit

Optimizations of CO 2 Water Alternating Gas(WAG)- systems with multi-objectives of incremental recovery and maximization of CO 2 storage are challenging. Here, the incorporation of a total Greenhouse gas (GHG) life cycle assessment is mostly ignored leading to inaccurate estimation of overall net carbon emissions of their operations. In this study, the effect of a total GHG life cycle assessment on a multi-objective CO 2 -WAG optimization with integrated techno-economic assessment (TEA) which factors carbon tax credit is conducted. A life cycle assessment (LCA) was conducted utilizing a 20 -year optimized post history matched data from a high fidelity reservoir simulation model. Using data generated from the optimum result, a techno-economic life cycle analysis was further conducted. The first scenario classified as the base model had an estimated 81% of purchased CO 2 sequestered. The results through a comprehensive techno-economic LCA model yielded a net estimate of 73% of purchased CO 2 . The optimized forecasted model which considered key operational and reservoir factors such as WAG ratio, injection rates and periods, and well specification resulted in an improved sequestration of 92% of purchased CO 2 . However, this also dropped to 84% after taking it through LCA. These results clearly indicate a significant amount of net CO 2 is not accounted for when operations are not analyzed through LCA. From the LCA, direct flaring volumes of CO 2 , energy consumption and efficiency of unit equipment were noticed to be the major causes of these reductions. Considering ten main sources of energy as source of energy generation, a comparative techno-eco LCA was conducted. The results confirmed a lower net volume and NPV for energy sources with higher carbon footprints and vice versa. Thus, a total LCA of CO 2 -WAG greatly influences net storage factor of purchased CO 2 and hence project NPV where tax credit/incentives per ton of CO 2 sequestered is considered. Although operational conditions are optimized for best results, there are significant factors that leads to minimization of net storage factor. This study therefore provides an insightful information for optimizing CO 2 -WAG multi-objectives to achieve minimum GHG emission.

02 PETROLEUM↗

A Gate-to-Gate Life Cycle Assessment for the CO 2 -EOR Operations at Farnsworth Unit (FWU)

Greenhouse gas (GHG) emissions related to the Farnsworth Unit’s (FWU) carbon dioxide enhanced oil recovery (CO 2 -EOR) operations were accounted for through a gate-to-gate life cycle assessment (LCA) for a period of about 10 years, since start of injection to 2020, and predictions of 18 additional years of the CO 2 -EOR operation were made. The CO 2 source for the FWU project has been 100% anthropogenically derived from the exhaust of an ethanol plant and a fertilizer plant. A cumulative amount of 5.25 × 106 tonnes of oil has been recovered through the injection of 1.64 × 106 tonnes of purchased CO 2 , of which 92% was stored during the 10-year period. An LCA analysis conducted on the various unit emissions of the FWU process yielded a net negative (positive storage) of 1.31 × 106 tonnes of CO 2 equivalent, representing 79% of purchased CO 2 . An optimized 18-year forecasted analysis estimated 86% storage of the forecasted 3.21 × 106 tonnes of purchased CO 2 with an equivalent 2.90 × 106 tonnes of crude oil produced by 2038. Major contributors to emissions were flaring/venting and energy usage for equipment. Improvements on the energy efficiency of equipment would reduce emissions further but this could be challenging. Improvement of injection capacity and elimination of venting/flaring or fugitive gas are methods more likely to be utilized for reducing net emissions and are the cases used for the optimized scenario in this work. This LCA illustrated the potential for the CO 2 -EOR operations in the FWU to store more CO 2 with minimal emissions.

54 ENVIRONMENTAL SCIENCES↗