Search NASA⌕ Search

Engineering topics

Groeneweg, J. F.

Publications and source records attributed to Groeneweg, J. F..

44 records · Page 3

An experimental study of the effect of treated length on fan inlet noise suppressors

The effect of length of acoustic treatment was studied on a full scale fan using two different inlets. Analysis of the data revealed that measured suppression varied linearly with the length of the ringed liner segments as anticipated. Further analysis indicated that the wall only portion of the treatment was substantially more effective than anticipated, suggesting that, if only moderate suppression is needed, wall only treatment may suffice. The two inlets behaved similarly. Introduction of a hard exhaust splitter into the configuration resulted in a noise increase at certain frequencies.

Dittmar, J. H.↗

Measured noise of model fan-under-wing and fan-on-flap jet flap configurations

Noise measurements were made on two jet flap systems proposed for STOL aircraft. In one case a 14.0-cm- (5.5-in.-) diameter fan was mounted under the wing such that the exhaust impinged on downwardly deflected flap segments. In the other case, the fan was located on the upper surface of the flap such that fan and flap moved as a unit, with no exhaust impingement. Results for takeoff and approach fan speeds and flap deflections were used to estimate STOL airplane perceived noise levels. Internally generated noise directivity corresponded with fan axis orientation for the fan-on-flap, but no consistent redirection of internal noise was observed with changes in flap angle for the fan-under-wing. With the fan-on-flap arrangement, the wing shielded some fan inlet noise from the ground. Since no impingement of the exhaust on solid surfaces occurred, the external noise was jet noise alone. In contrast, for the fan-under-wing, the jet/flap interaction noise dominated the external noise except at angles near the jet axis even with no flap deflection. If internal noise is reduced by fan design and acoustic treatment, the jet/flap interaction noise will dominate.

Groeneweg, J. F.↗

Fan noise suppression

The principal suppressor parameters and their relationships have been used to formulate a suppressor design methodology which has been applied to the design of several full-scale suppressors. Tests of these suppressors on several full-scale fans have demonstrated noise reductions of the order of 10 PNdB. The amount of suppression in several instances seems to have been limited by reaching noise floors that are not clearly at the estimated jet noise level but are not far above it. In addition to identifying noise floors, two other areas are considered. The first is attenuation by the fan exhaust suppressors, which seems in most cases to be less than that of the inlet. The second is the effectiveness of outer cowl treatment alone on multiple pure tones. This question relates to whether a high-speed fan can become as quiet as a low-speed fan without a substantial increase in the amount of treatment.

Feiler, C. E.↗