Enhanced fluorescence from X-ray line coincidence pumping of K-pumped Cl and Mg-pumped Ge plasmas
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Gu, M F.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We measured the L-shell emission spectrum of Fe XVII in a low-density, low-gradient magnetically confined laboratory plasma that contains predominantly C, O, Fe, and Ni as trace elements and find excellent agreement with the relative spectral emission obtained in solar and astrophysical observations. However, we obtained spectra that appear to have an usually large 1s^22s^22p^5_{1/2}3d_{3/2} --> 1s^22s^22p^6 Fe XVII resonance transition, commonly labeled 3C, from hot plasmas that also contain F. The wavelength of the Ly-alpha feature of F IX is coincident with the wavelength of the Fe XVII line 3C within one part in 538, and its flux, therefore, enhances the Fe XVII resonance line. Moreover, the resonance and forbidden lines of F VIII are close to the 3s --> 2p transitions in Fe XVII, and may further alter the inferred apparent Fe XVII line ratios, particularly in spectrometers with moderate spectral resolution. The enhanced emission of line 3C, thus, can serve as a new spectral diagnostic for the detection of fluorine in astrophysical plasmas.
Abstract not provided
The parameters of the ITER core plasmas will be measured using the Core Imaging X-ray Spectrometer (CIXS), a high-resolution crystal spectrometer focusing on the L-shell spectra of highly ionized tungsten atoms. In order to correctly infer the plasma properties accurate atomic data are required. Here, some aspects of the underlying physics are discussed using experimental data and theoretical predictions from modeling.
We have been making spectral measurements in the extreme ultraviolet (EUV) from different laboratory sources in order to investigate the electron density dependence of various astrophysically important emission lines and to test the atomic models underlying the diagnostic line ratios. The measurement are being performed at the Livermore EBIT-I electron beam ion trap, the National Spherical Torus Experiment (NSTX) at Princeton, and the Alcator C-Mod tokamak at the Massachusetts Institute of Technology, which together span an electron density of four orders of magnitude and which allow us to test the various models at high and low density limits. Here we present measurements of Fe XXII and Ar XIV, which include new data from an ultra high resolution ({lambda}/{Delta}{lambda} >4000) spectrometer at the EBIT-I facility. We found good agreement between the measurements and modeling calculations for Fe XXII, but poorer agreement for Ar XIV.
We measured wavelengths and intensities of L-shell emission lines of aluminum in the extreme ultraviolet wavelength band. We identify 75 features of Al IV through Al XI between 40 and 170 A. The strongest features are due to 3 {yields} 2 transitions; features from 4 {yields} 2, 5 {yields} 2, and 6 {yields} 2 transitions are also included. Calculations made with the Flexible Atomic Code using the configuration-interaction method and many-body perturbation theory are presented and compared to the experimental results.
We analyzed spectral data of Fe XXII and Ar XIV from laboratory sources in which the electron density varies by several orders of magnitude to help benchmark density-sensitive emission lines useful for astrophysics and to test the atomic models underlying the diagnostic line ratios. We found excellent agreement for Fe XXII, but poorer agreement for Ar XIV. A number of astrophysically important emission lines are sensitive to electron density in the EUV and soft X-ray regions. Lines from Fe XXII, for example, have been used in recent years as diagnostics of stellar coronae, such as the active variable AB Dor, Capella, and EX Hya (Sanz-Forcada et al. 2003, Mewe et al. 2001, Mauche et al. 2003). Here we report spectral data of Fe XXII and Ar XIV from laboratory sources in which the electron density is known from either K-shell density diagnostics (for electron beam ion traps) or from non-spectroscopic means (tokamaks), ranging from 5 x 10{sup 10} cm{sup -3} to 5 x 10{sup 14} cm{sup -3}. These measurements were used to test the atomic data underlying the density diagnostic line ratios, complementing earlier work (Chen et al. 2004).
The electric quadrupole (E2) and magnetic octupole (M3) ground-state transitions in Ni-like W{sup 46+} have been measured using high-resolution crystal spectroscopy at the LLNL electron-beam ion trap facility. The lines fall in the soft x-ray region near 7.93 A and were originally observed as an unresolved feature in tokamak plasmas. Using flat ammonium dihydrogen phosphate and quartz crystals, the wavelengths, intensities, and polarizations of the two lines have been measured for various electron-beam energies and compared to intensity and polarization calculations performed using the Flexible Atomic Code (FAC).
The electric quadrupole (E2) and magnetic octupole (M3) ground state transitions in Ni-like W{sup 46+} have been measured using high-resolution crystal spectroscopy at the Livermore electron beam ion trap facility. The lines fall in the soft x-ray region near 7.93 {angstrom} and were originally observed as an unresolved feature in tokamak plasmas. Using flat ADP and quartz crystals the wavelengths, intensities, and polarizations of the two lines have been measured for various electron beam energies and compared to intensity and polarization calculations performed using the Flexible Atomic Code (FAC).
Most tokamak-based reactor concepts require the use of noble gases to form either a radiative mantle or divertor to reduce conductive heat exhaust to tolerable levels for plasma facing components. Predicting the power loss necessary from impurity radiation is done using electron temperature-dependent 'cooling-curves' derived from ab initio atomic physics models. We present here a technique to verify such modeling using highly radiative, argon infused discharges on Alcator C-Mod. A novel x-ray crystal imaging spectrometer is used to measure spatially resolved profiles of line-emissivity, constraining impurity transport simulations. Experimental data from soft x-ray diodes, bare AXUV diodes and foil bolometers are used to determine the local emissivity in three overlapping spectral bands, which are quantitatively compared to models. Comparison of broadband measurements show agreement between experiment and modeling in the core, but not over the entire profile, with the differences likely due to errors in the assumed radial impurity transport outside of the core. Comparison of Ar{sup 16+} x-ray line emission modeling to measurements suggests an additional problem with the collisional-radiative modeling of that charge state.
A high-resolution flat-crystal spectrometer was used on the SuperEBIT electron beam ion trap to measure the energies of the 2s{sub 1/2} - 2p{sub 3/2} transitions in lithiumlike through fluorine-like tungsten. These transitions are strongly affected by energy shifts due to quantum electrodynamics (QED). SuperEBIT was run at an electron energy of 103.2 {+-} .5 keV and an electron beam current of 150 mA to generate the respective charge states; hydrogenlike aluminum and neonlike krypton were used as calibration elements. The spectra were analyzed with and the results compared to calculations based on the Flexible Atomic Code. Good agreement was found. The measurements yielded line positions with a precision of 1-2 eV, which test QED calculations to about 5-10%.
The M-shell x-ray emission of highly charged tungsten ions has been investigated at the Livermore electron beam ion trap facility. Using the SuperEBIT electron beam ion trap and a NASA x-ray calorimeter array, transitions connecting the ground configurations in the 1500-3600 eV spectral range of zinc-like W{sup 44+} through cobalt-like W{sup 47+} have been measured. The measured spectra are compared with theoretical line positions and emissivities calculated using the FAC code.