Turbine-mounted LIDAR Validation
Validation results from commercially available LIDAR mounted on a ECO110 prototype Turbine.
Engineering topics
Publications and source records attributed to Guadayol, Marc.
Validation results from commercially available LIDAR mounted on a ECO110 prototype Turbine.
Review commercially available LIDAR Systems and Compare LIDAR using simulations in Bladed
Typical wind turbines utilize feedback controllers which have a delayed response to wind speed disturbances. A nacelle mounted LIght Detection and Ranging (LIDAR) system measures a preview wind signal in front of the turbine. This can be included in a feed-forward control system, improving turbine pitch command for incoming variations in wind speed. The overall aim is reduced blade and tower fatigue, and potentially improved annual energy production. To be successful, the LIDAR must yield accurate wind speed measurements. Therefore, a LIDAR was characterized against a nearby met tower and turbine wind speed estimator. Results indicate good correlation between measurements.
Typical wind turbines utilize feedback controllers which have a delayed response to winds peed disturbances. A nacelle mounted LIght Detection and Ranging(LIDAR) system measures a preview wind signal in front of the turbine. This can be included in a feed-forward control system, improving turbine pitch command for incoming variations in wind speed. The overall aim is reduced blade and tower fatigue, and potentially improved annual energy production. To be successful, the LIDAR must yield accurate wind speed measurements. Therefore, a LIDAR was characterized against a nearby met tower and turbine wind speed estimator. Results indicate good correlation between measurements.