Detector Wall Research for Fast Gamma Signal Detection in Neutron-Diagnosed Subcritical Experiment Applications
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Guckes, Amber.
Explore the source record for details and available documents.
Presentation to be presented during the Site-Directed Research and Development (SDRD) program FY 2021 review meeting (Webex), September 22–23, 2021.
Presentation to be presented during the Site-Directed Research and Development (SDRD) FY 2021 review meeting (Webex), September 22–23, 2021.
Explore the source record for details and available documents.
The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.
The purpose for the Neutron-Diagnosed Subcritical Experiment (NDSE) Static Test Series at the Nevada National Security Site (NNSS) Area 11 is to develop and validate the capability to make precise and accurate measurements of k eff for Special Nuclear Material (SNM) targets with k eff ~ 0.95.1 The series has now completed six sets of measurements using the deuterium-tritium (DT) Dense Plasma Focus (DPF) neutron source, with a Rocky-Flats-Shells Highly Enriched Uranium (RF HEU) target, to measure the gamma die-away to this purpose. The last of these series, Series V and VI, are the subject of this report. Both series were performed on a target comprised of the Object IV HEU + CH 2 configuration, which is identical to Object II but with smaller DPF collimators that limit the incident neutron flux to the HEU radius.
Manuscript for a poster to be presented at SPIE Optics + Photonics 2020 Digital Forum, 24-28 August 2020, https://spie.org/opo/conferencedetails/x-ray-gamma-ray-neutron-detector-physics.
Presentation describes the application of the Bodnarik method of acquiring gamma spectra in fixed time windows to determine the constituency of the materials, the mass of the materials, and the determination of the presence of Special Nuclear Material and High Explosives.
Presentation describes proposal to develop accurate end-to-end detector solutions that meet experimental requirements, using a simulation toolkit that enables evaluation of detector performance and decision-making.
This prospectus will be distributed to my dissertation committee. A portion of my research (the handheld multimode radiation sensor) was conducted under SDRD RSLN-009-16, Tri-mode Radiation Sensor.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In investigations of Ce3+-doped Cs2LiLa(Br6)90%(Cl6)10% (CLLBC) elpasolite crystals, the crystals show an excellent neutron and gamma (n/g) radiation response. The results of our studies on the scintillation properties of CLLBC viz. radioluminescence, energy resolution, light yield, decay times, and nonproportionality are discussed. The CLLBC detector can provide energy resolution as good as 4.1% at 662 keV (FWHM), which is better than that of NaI:Tl. Because the crystal contains 6Li, CLLBC can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 MeV gamma equivalent energy. This high-energy signature for the thermal neutron peak means that very effective pulse height discrimination is possible. Unfortunately, because the core-to-valence luminescence observed in other elpasolites that can be exploited for effective pulse shape discrimination (PSD) is not observed in the CLLBC, other strategies for obtaining the PSD of CLLBC are needed. The n/g discrimination capability of CLLBC detectors may be optimized by tuning the cerium doping content for maximum effect on n/g pulse shape differences. The value of adding a chlorine component to the nominal CLLB crystal is discussed. Because the crystal contains chlorine, its sensitivity to fast neutrons is better than that of Cs2LiLaBr6 (CLLB). Further, an array of three of these CLLBC detectors may be able to perform directional detection in both the neutron and gamma channels simultaneously.
Explore the source record for details and available documents.