Search NASA⌕ Search

Engineering topics

Guckes, Amber L

Publications and source records attributed to Guckes, Amber L.

Charge multiplication in thin scCVD diamond detectors

This presentation describes experimental measurements with thin scCVD diamond detectors and their DD and DT neutron sources. This presentation will be given at the NNSS Prompt Radiation Detection and Imaging Workshop April 25-28, 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct current response of a thin scCVD diamond detector under increased applied field to 14.1 MeV neutrons

An avalanche effect yielding inherent gain can be exploited in thin, single-crystal chemical vapor deposition (scCVD) diamond. It occurs when a high enough bias is applied across the diamond thickness while avoiding breakdown. This charge multiplication effect was studied previously with alpha particles and heavy ions either by using the transient current technique or by measuring the energy spectrum. The measurements we obtained to evaluate the charge multiplication performance of a 10 μm thick scCVD diamond detector used a novel approach—we employed an electrometer to characterize the response of the detector by performing directly coupled current measurements (time-averaged charge, at 1 Hz sampling) when exposed to 14.1 MeV neutrons from deuterium-tritium fusion. We measured both the dark and irradiated currents from the detector over a range of applied displacement field values from 2 to 75 V/μm. A histogram method with central mean and standard deviation width was used to determine the current over each measurement duration typically from 100 to 300 seconds. The dark-subtracted irradiated current (i.e., contrast) was used to evaluate the gain of the detector at each applied displacement field. The contrast at an applied displacement field between 15 and 20 V/μm was higher than the expected linear increase in contrast proportional to the increased applied bias, indicating the possible presence of avalanche events in the diamond. The detector response also indicated possible polarization and charge depletion effects. These results provide an opportunity to further explore the use of thin scCVD diamond as a fast neutron current mode detector with inherent gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BYU Capstone Next Generation Vacuum Compton Detector

This BYU Capstone Team Gamma final poster summarizes the work of the team towards a next generation vacuum Compton detector (VCD) for the Nevada National Security Site. The NNSS sponsored this team. Amber Guckes was the mentor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗