Search NASA⌕ Search

Engineering topics

Guenette, R. [Manchester U.]

Publications and source records attributed to Guenette, R. [Manchester U.].

High voltage delivery and distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid andgas time projection chambers (TPCs) is the delivery and distributionof high voltages into and around the detector. Such experimentsrequire of order tens of kilovolts to enable electron drift overmeter-scale distances. This paper describes the design andoperation of the cathode feedthrough and high voltage distributionthrough the field cage of the NEXT-100 experiment, an undergroundTPC that will search for neutrinoless double beta decay0νββ. The feedthrough has been demonstrated to holdpressures up to 20 bar and sustain voltages as high as -65 kV.The TPC is operating stably at its design high voltages. The systemhas been realized within the constraints of a stringent radiopuritybudget and is now being used to execute a suite of sensitive doublebeta decay analyses.

Adams, C. [Argonne]↗

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of $^{208}$Tl decays

A detailed understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in liquid argon time projection chambers (LArTPCs). This study presents a measurement of the resolution of reconstructed energy in the MicroBooNE LArTPC at $\approx 1.5$ MeV. The characterization is performed using monoenergetic signals generated by $2.614$ MeV $γ$-rays from $^{208}$Tl decays undergoing pair production in the detector. The resolution is found to be ($7.52 \pm 0.78 \text{(stat)} \pm 0.92 \text{(syst)}$)%. This value is consistent with the MicroBooNE simulation prediction of ($9.70 \pm 0.65 \text{(stat)}$)% at the $1.6 σ$ level. This study represents the first ever measurement of LArTPC energy resolution at the MeV scale and provides a pathway for monoenergetic energy calibrations in future experiments using LArTPC detectors.

Abratenko, P. [Tufts U.]↗

Electroluminescence Yield Measurements in Xenon Gas with the NEXT-DEMO++ Detector

The NEXT-DEMO++ detector, a high-pressure xenon gas time projection chamber serving as a prototype for the NEXT-100 experiment, was used to measure the electroluminescence (EL) yield as a function of reduced electric field ($E/p$) across pressures from 2.0 to 9.4 bar, utilizing the 41.5 keV de-excitation peak of $^{83m}$Kr. These measurements were made to examine the pressure dependence of the slope of the reduced EL yield $Y/p$, which has shown inconsistencies in the literature. The reduced yield was fitted with a linear model, revealing a modest ($\sim$5%) change in slope, beginning around 5 bar and increasing with pressure up to 9.4 bar.

Renner, J. [Valencia U., IFIC]↗

Scintillation light calibrations, systematic uncertainties, and triggering efficiency in the MicroBooNE detector

Scintillation light, produced alongside ionisation charge from particle interactions, plays a critical role in liquid argon time projection chamber (LArTPC) detectors. A detailed understanding of its production and detection mechanisms is essential for robust calibration, systematic uncertainty evaluation, and physics analysis. This article describes the MicroBooNE light simulation, light-based triggering schemes, photomultiplier tube gain calibration, light response stability, and light-based systematic uncertainties over the course of five years of data collection. In addition, we present a measurement of scintillation light triggering efficiency, focusing on the lowest-light regime relevant to rare-event searches and low-energy neutrino interactions. Finally, we discuss two notable observations in MicroBooNE's data, both reported here for the first time: an approximately 50% decline in MicroBooNE's light yield over time, concentrated in the first two years of running; and a higher than expected O(200 kHz) rate of single photoelectron noise. The results presented provide an important benchmark of long-term light detection performance in LArTPC neutrino detectors.

Abratenko, P. [Tufts U.]↗

Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ($ββ0ν$) of Xe-136. The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ($Q_{ββ}$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a Th-228 source, demonstrating linear response and an energy resolution of $(0.90 \pm 0.02)$% FWHM at the Tl-208 photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $R(Q_{ββ})$ = $(0.93 \pm 0.02)$% FWHM, confirming the detector's capability for precision energy measurement in the search for $ββ0ν$.

Pérez Maneiro, M. [Santiago de Compostela U., IGFA↗

Measurement of three-dimensional inclusive muon-neutrino charged-current cross sections on argon with the MicroBooNE detector

We report the measurement of the triple-differential cross section d 3 σ/dE vis d cos(θ μ )dP μ for inclusive muon-neutrino charged-current scattering on argon. This measurement utilizes data from 6.4 x 10 20 protons on target of exposure collected using the MicroBooNE liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam with a mean neutrino energy of approximately 0.8 GeV. The mapping from reconstructed kinematics to truth quantities is validated within uncertainties by comparing the distribution of reconstructed hadronic energy in data to that of the model prediction in different muon scattering angle bins after applying a conditional constraint from the muon momentum distribution in data. The success of this validation provides confidence that the energy transfer in the MicroBooNE detector is well-modeled within simulation uncertainties, enabling a reliable unfolding to a triple-differential cross section defined at the nominal neutrino flux over muon momentum, muon scattering angle, and visible neutrino energy. This validation not only supports accurate cross-section extraction, but also establishes a critical foundation for tuning interaction models used in future neutrino oscillation measurements. The unfolded measurement covers an extensive phase space, providing a wealth of information useful for future liquid argon time projection chamber experiments measuring neutrino oscillations. Comparisons against a number of commonly used model predictions are included and their performance in different parts of the available phase-space is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗