Search NASA⌕ Search

Engineering topics

Gueye, Paul

Publications and source records attributed to Gueye, Paul.

The United States Department of Energy and National Institutes of Health Collaboration: Medical Care Advances by Discovery in Radiation Detection

A National Institutes of Health (NIH) and U.S. Department of Energy (DOE) Office of Science virtual workshop on shared general topics was held in July of 2021 and reported on in this publication in January of 2023. Following the inaugural 2021 joint meeting representatives from the DOE Office of Science and NIH met to discuss organizing a second joint workshop that would concentrate on radiation detection to bring together teams from both agencies and their grantee populations to stimulate collaboration and efficiency. To meet this scientific mission within the NIH and DOE radiation detection space, the organizers assembled workshop sessions covering the state–of–the–art in cameras, detectors, and sensors for radiation external and internal (diagnostic and therapeutic) to human, data acquisition and electronics, image reconstruction and processing, and the application of artificial intelligence. NIH and DOE are committed to continuing the process of convening a joint workshop every 12–24 months. This Special Report recaps the findings of this second workshop. Beyond showing only the innovations and areas of success, important gaps in our knowledge were defined and presented. Finally, we summarize by defining four areas of greatest opportunity and need that emerged from the unique, dynamic dialogue the in–person workshop provided the attendees.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The United States Department of Energy and National Institutes of Health Collaboration: Medical Care Advances via Discovery in Physical Sciences

Over several months, representatives from the U.S. Department of Energy (DOE) Office of Science and National Institutes of Health (NIH) had a number of meetings that lead to the conclusion that innovations in the Nation's health care could be realized by more directed interactions between NIH and DOE. It became clear that the expertise amassed and instrumentation advances developed at the DOE physical science laboratories to enable cutting-edge research in particle physics could also feed innovation in medical healthcare. To meet their scientific mission, the DOE laboratories created advances in such technologies as particle beam generation, radioisotope production, high-energy particle detection and imaging, superconducting particle accelerators, superconducting magnets, cryogenics, high-speed electronics, artificial intelligence, and big data. To move forward, NIH and DOE initiated the process of convening a joint work- shop which occurred on July 12th and 13th, 2021. Here, this Special Report presents a summary of the findings of the collaborative workshop and introduces the goals of the next one.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Meson Photo-Production in GEANT4 for $E_\gamma = 0.225$ E γ = 0 . 225 -3.0 GeV using the $\gamma + p \rightarrow p + \pi^{0}$ reaction

The study of nuclear resonances in the intermediate energy regime requires accurate modeling of the experimental physics background. The cross sections in the GEANT4 toolkit do not adequately treat meson photo-production. The purpose of this study is to compare experimental data and theoretical models implemented in version 9.6.p02 of the GEANT4 Monte Carlo simulation toolkit for the exclusive and differential cross sections of $\pi^0$ photo-production. Two models were studied: the Chiral Invariant Phase Space (CHIPS) and Bertini Cascade (BERT). The cross section data from the models were compared to the experimental data from the CEBAF Large Acceptance Spectrometer (CLAS) of Jefferson Lab and the phenomenological Scattering Analysis Interactive Dial-in (SAID) model. Relativistic Breit-Wigner fits were used to compare the $\Delta(1232)$, N*(1520), N*(1650) and N*(1875) resonances from SAID, CLAS and CHIPS, giving agreements to within 3% for the mass of each resonance. The limited tabulated data set of BERT does not allow for an accurate description of the energy distribution, even following its improvement in version 10p02. The angular distributions of the cross sections show significant differences between CHIPS and both CLAS and SAID data, the latter being the most accurate model to describe the $\gamma p\rightarrow p\pi ^0$ exclusive cross section. Finally, the physics in CHIPS appears to be correct but it needs further development for the individual resonances contributions that could be useful since it is also the only model able to treat electromagnetically induced meson production for $A>1$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the Repulsive Core of the Nucleon-Nucleon Interaction via the 4 He(e,e`pN) Triple-Coincidence Reaction

We studied simultaneously the 4 He(e,e'p), 4 He(e,e'pp), and 4 He(e,e'pn) reactions at Q 2 =2 [GeV/c] 2 and x B >1, for a (e,e'p) missing-momentum range of 400 to 830 MeV/c. The knocked-out proton was detected in coincidence with a proton or neutron recoiling almost back to back to the missing momentum, leaving the residual A=2 system at low excitation energy. These data were used to identify two-nucleon short-range correlated pairs and to deduce their isospin structure as a function of missing momentum in a region where the nucleon-nucleon force is expected to change from predominantly tensor to repulsive. Neutron-proton pairs dominate the high-momentum tail of the nucleon momentum distributions, but their abundance is reduced as the nucleon momentum increases beyond ~500 MeV/c. The extracted fraction of proton-proton pairs is small and almost independent of the missing momentum in the range we studied. Our data are compared with ab-initio calculations of two-nucleon momentum distributions in 4 He.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of the Λ ⁷He Hypernucleus by the (e, e'K⁺) Reaction

An experiment with a newly developed high-resolution kaon spectrometer and a scattered electron spectrometer with a novel configuration was performed in Hall C at Jefferson Lab. The ground state of a neutron-rich hypernucleus, He Λ ⁷, was observed for the first time with the (e, e'K⁺) reaction with an energy resolution of ~0.6 MeV. This resolution is the best reported to date for hypernuclear reaction spectroscopy. The He Λ ⁷ binding energy supplies the last missing information of the A=7, T=1 hypernuclear isotriplet, providing a new input for the charge symmetry breaking effect of the ΛN potential.

Nakamura, S. N.↗

SU-GG-T-49: Real Time Dose Verification for Novel Shielded Balloon Brachytherapy

Purpose: The validation of a novel approach for reducing skindoses to an acceptable level during Accelerated Partial Breast Irradiation (APBI) when the balloon-to-skin distance is inadequate (less than 7 mm) is reported. The study uses a real time dose verification method for a metallic shielded balloon applicator using scintillation fiber technology. Method and Materials: Partial shielding of the radiationdose to the skin using iron or other ferrous powder could enable the extension of APBI to some patients. With small external and pre-determined magnetic fields (<few Gauss), the metallic elements deposition can be controlled on the inner surface of a balloon. Geant4 simulations were used to generate an attenuation dose curve for various radiation lengths after cross-calibration with dedicated data acquired at Jefferson Lab. Some powder was then injected into various inflated MammoSite and rectal balloons within realistic breast and torso phantoms of differing sizes. The dose on the external surface of the skin was measured from a 6.1 Ci {sup 192}Ir of a GammaMed 12i afterloader unit, with a MOSFET,ion chamber and scintillating fiber array detectors. Results: Realistic Monte Carlo simulation studies for the amount and distribution of the required shielding material were compared to dedicated phantom data. A decrease of the skindose was measured to an acceptable level (~350-450 cGy) during standard breast Brachytherapy treatments with relatively weak magnetic fields. Additional measurements provided negligible corrections (< few %) on the saline water density from the suspended ironpowder.Conclusion: This project opens the possibility to increasing the survival expectancy and minimizing negative side effects during brachytherapy treatments, as well as improving cosmetic outcome for all APBI patients. The proposed method may also be used in other procedures for brain, heart, rectal, or vaginal cancers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Energy Differential Response of Cancer Cells for Low Dose Irradiation:Impact of Monoenergetic Brachytherapy Sources

Purpose: The purpose of this work was to evaluate the energy differential response of cancer cells under identical dose exposure to asses the relevancy of mono-energetic sources for Brachytherapy treatments. Method and Materials: An electron energy spectrum impinging on lived breast cancer cell lines (MDA321) was obtained by placing a 19.65 {micro}Ci {sup 90}Sr/{sup 90}Y radioactive source in front of a non-uniform magnetic field constructed from two 5.08 x 5.0 cm x 2.54 cm neodimium ion permanent dipole magnets with a 1 cm separation gap. The cell lines were placed on the exit pole face of the magnet and were subsequently irradiated with different electron energies ranging from about 0.75 MeV to 1.85 MeV. The energy distribution was accurately measured with a scintillating fiber detector system that provided a 0.5% agreement with ICRU and a 5% energy resolution. The dosimetry was performed using a series of data acquired with a {sup 9}Sr/{sup 90}Y 4.5 mCi SIA-6 eye applicator, 6-21 MeV fixed energies from a Varian 2100 EX linac, EBT Gafchromic and Kodak ERT2 films, and an ion chamber detector. The accuracy of the dose rate obtained at different locations along and away from the magnet inside the cell containers was within 10.7%. Results: The cell lines were irradiated with a 0.5-4 Gy dose range. The data indicate a very strong differential energy response for electrons around 1 MeV (more lethal) compare to those with lesser or greater energy and a survival rate of at most 10% at very low dose (0.5-2 Gy). Conclusion: Mono-energetic Brachytherapy sources may provide a new pathway for radio-therapy treatment optimizations following a dedicated study showing very unusual high lethality in a specific energy window for MDA321 breast cancer cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Brief summary on past workshops for a positron beam at JLab

The idea of a positron beam at Jefferson Lab goes back to the mid-1990s with the possibility of adding a materials science beamline. For the next decade, a few workshops were conducted to address the physics and associated beam requirements. As alternate venues, two other facilities have been investigated using ultrafast laser technology (in the US) and a conventional RF system (in Senegal). We will review the various historical timeline and subsequent outcomes of these workshops, in addition to presenting briefly the proposed two facilities.

43 PARTICLE ACCELERATORS↗

SU-FF-T-390: In-Vivo Prostate Brachytherapy Absorbed Dose Measurements

Purpose: In-vivo prostate brachytherapy absorbed dosimetrydetector using scintillating fibers. Method and Materials: Five pairs of 85.5 {+-} 0.05 cm long blue shifted scintillating fibers (model BCF-10) with 1 mm{sup 2} cross sectional area were placed in a mixture of gelatin (368.6 {+-} 0.5 grams) and water (3.78 {+-} 0.025 liters) to measured the absorbed dose delivered by a 12 Ci {sup 192}Ir HDR source. The fibers were held by a 7 x 7 cm{sup 2} template grid and optically connected to a 16-channel multianode photomultiplier tube (Hamamatsu, model H6568). Each pair consisted of one fiber 4 mm shorter than the other one to extract the dose by the subtraction method. A dose atlas was used for radiation delivered to the phantom. The plans followed delivered 5 and 7 Gy to a point located 2.0 centimeters away from the central dwelling positions. A total of 32 data points were acquired in a plan to assess the linearity and reproducibility of the measurements.Results: Reproducibility of the data was found to be within 5% and the overall accuracy of the system estimated to be {+-}5.5%. The linearity of the data for all 7 measureddose values (ranging from 0.6 to 7 Gy), gives a slope of 312 counts/Gy with a 1.4% relative deviation. Conclusion: This work indicates the possibility of measuring in real-time the dose effectively delivered to a biological system during prostate brachytherapy treatments. The availability of commercially thin (150 {micro}m) scintillating fibers opens the capability of using such system during clinical treatments (by embedding the fibers within the catheters) with the advantage of performing real-time adjustment of the dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-FF-T-469: Energy Spectra Reconstruction From Beta Emitters: A Study of the Sr-90/Y-90 Case

Purpose: Reconstruction of the energy spectrum of a 90Sr/90Yradioactive source for low dose (~1Gy) radiation biology experiments. Method and Materials:Electrons originated from a 25 {micro}Ci 90Sr/90Yradioactive source were recently used in radio-biology experiments to study the response of cancer cells to low dose irradiation (~1Gy). The beam was separated into individual energies using a dipole magnet, the number of exited electronsmeasured by a scintillating fiber based detector and the dose obtained using double-layered EBT films. The dipole was constructed from two 5.08 x 5.08 x 2.54 cm{sup 3}permanent magnets separated by a distance of 2 cm and having a maximum field of about 5 kG at the center. The beam entered the magnet through a 1 cm diameter, 0.5 cm thick leaded glass collimator. The detector was an array of 16 blue shifted 1 mm thick scintillating fibers. A realistic Geant4 simulation was used to account for the energy loss while electrons propagate throughout the system. The incident energy spectrum was generated from the NIST-logft calculation. Results: The data was first compared with measurements using a pancake frisker detector for an overall general assessment of the data quality, giving an agreement to within 15%. The average deviation of the data/simulation ratio is {+-}2.5%. A comparison between the measured and simulated mean energies gives an agreement to within 1{sigma} (less than 0.3%). Conclusion: The simple system developed for this work can serve as a mean for an efficient way to accurately reconstruct the energy distribution of charged particle emitters as well as to assess expected dose delivery to biological systems. Such data can also be used to benchmark low energy physics processes implemented in simulation tools for medical physics purpose.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-FF-T-668: A Simple Algorithm for Range Modulation Wheel Design in Proton Therapy

Purpose: To develop a simple algorithm in designing the range modulation wheel to generate a very smooth Spread-Out Bragg peak (SOBP) for proton therapy.Method and Materials: A simple algorithm has been developed to generate the weight factors in corresponding pristine Bragg peaks which composed a smooth SOBP in proton therapy. We used a modified analytical Bragg peak function based on Monte Carol simulation tool-kits of Geant4 as pristine Bragg peaks input in our algorithm. A simple METLAB(R) Quad Program was introduced to optimize the cost function in our algorithm. Results: We found out that the existed analytical function of Bragg peak can&#x27;t directly use as pristine Bragg peak dose-depth profile input file in optimization of the weight factors since this model didn&#x27;t take into account of the scattering factors introducing from the range shifts in modifying the proton beam energies. We have done Geant4 simulations for proton energy of 63.4 MeV with a 1.08 cm SOBP for variation of pristine Bragg peaks which composed this SOBP and modified the existed analytical Bragg peak functions for their peak heights, ranges of R{sub 0}, and Gaussian energies {sigma}{sub E}. We found out that 19 pristine Bragg peaks are enough to achieve a flatness of 1.5% of SOBP which is the best flatness in the publications. Conclusion: This work develops a simple algorithm to generate the weight factors which is used to design a range modulation wheel to generate a smooth SOBP in protonradiation therapy. We have found out that a medium number of pristine Bragg peaks are enough to generate a SOBP with flatness less than 2%. It is potential to generate data base to store in the treatment plan to produce a clinic acceptable SOBP by using our simple algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypernuclear spectroscopy program at JLab Hall C

DOI: http://dx.doi.org/10.1016/j.nuclphysa.2008.01.029 Hypernuclear production by the (e,e?K+) reaction has unique advantages in hypernuclear spectroscopy of the S=?1 regime. The second-generation spectroscopy experiment on 12C, 7Li and 28Si targets has been recently carried out at JLab Hall C with a new experimental configuration (Tilt method) and also using a new high-resolution kaon spectrometer (HKS). The experiment is described and preliminary results are presented together with the empasis of significance of the (e,e?K+) reaction for ? hypernuclear spectroscopy and its future prospects.

Hashimoto, Osamu↗