Search NASA⌕ Search

Engineering topics

Gul, R

Publications and source records attributed to Gul, R.

27 records · Page 2

Extended defects in CdZnTe crystals: Effects on device performance

We explored some unique defects in a batch of cadmium zinc telluride (CdZnTe) crystals, along with dislocations and Te-rich decorated features, revealed by chemical etching. We extensively investigated these distinctive imperfections in the crystals to identify their origin, dimensions, and distribution in the bulk material. We estimated that these features ranged from 50 to 500 {micro}m in diameter, and their depth was about 300 {micro}m. The density of these features ranged between 2 x 10{sup 2} and 1 x 10{sup 3} per cm{sup 3}. We elaborated a model of them and projected their effect on charge collection and spectral response. In addition, we fabricated detectors with these defective crystals and acquired fine details of charge-transport phenomena over the detectors volume using a high-spatial resolution (25 {micro}m) X-ray response mapping technique. We related the results to better understand the defects and their influence on the charge-transport properties of the devices. The role of the defects was identified by correlating their signatures with the findings from our theoretical model and our experimental data.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Effective surface passivation of CdMnTe materials

Passivation is an important process that reduces surface leakage current and its attendant noise. We treated detector-grade large-volume CdMnTe:In samples with an (NH{sub 4})-based passivant, and compared the results with untreated samples by measuring current-voltage characteristics, surface recombination velocity, Raman spectroscopy, and charge-collection mapping. The leakage current of the passivated CdMnTe (CMT) detectors decreased five to ten times, and surface recombination declined five to six times, depending on the passivation conditions applied. We satisfactorily explained these improvements in detector performance as resulting from different passivation layers that were generated by distinct chemical reactions, as determined by the pH of the passivant.

36 MATERIALS SCIENCE↗

Defect levels and thermomigration of Te precipitates in CdZnTe:Pb

Semi-insulating Cd0.9Zn0.1Te:Pb crystals were grown by the vertical Bridgman method. Measurements of the current deep level transient spectroscopy (I-DLTS) revealed three trap levels in this material. Unlike other compensating dopants, CdZnTe:Pb samples do not show any Cd-vacancies defects and A-center levels. We subjected them to temperature-gradient annealing in Cd overpressure at 490–717 1C, and recorded an exponential relationship between the annihilation time of Te precipitates and the annealing temperature. The energy resolution of an annealed CdZnTe:Pb detector, tested using a 137Cs radioactive source, gave an energy resolution of 2.5%.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Investigations of Cadmium Manganese Telluride Crystals for Room-temperature Radiation Detection

Cadmium manganese telluride (CMT) has high potential as a material for room-temperature nuclear-radiation detectors. We investigated indium-doped CMT crystals taken from the stable growth region of the ingot and compared its characteristics with that from the last-to-freeze region. We employed different techniques, including synchrotron white-beam x-ray topography (SWBXT), current-voltage (I-V) measurement, and low-temperature photoluminescence spectra, and we also assessed their responses as detectors of radiation exposure. The crystal from the stable growth region proved to be superior to that from the last-to-freeze region; it is a single-grain crystal, free of twins, and displayed a resistivity higher by one order of magnitude. The segregation of indium dopant in the ingot might be responsible for its better resistivity. Furthermore, we recorded a good response in the detector fabricated from the crystal taken from the stable growth region; its ({mu}{tau})e value was 2.6 x 10{sup -3} cm{sup 2}/V, which is acceptable for thin detectors, including their application in medicine.

36 MATERIALS SCIENCE↗

Investigations of Cadmium Manganese Telluride Crystals for Room-Temperature Radiation Detection

Cadmium manganese telluride (CMT) has high potential as a material for room-temperature nuclear-radiation detectors. We investigated indium-doped CMT crystals taken from the stable growth region of the ingot, and compared its characteristics with that from the last-to-freeze region. We employed different techniques, including synchrotron white-beam X-ray topography (SWBXT), current-voltage (I-V) measurements, and low-temperature photoluminescence spectra, and we also assessed their responses as detectors to irradiation exposure. The crystal from the stable growth region proved superior to that from the last-to-freeze region; it is a single-grain crystal, free of twins, and displayed a resistivity higher by two orders-of-magnitude. The segregation of indium dopant in the ingot might be responsible for its better resistivity. Furthermore, we recorded a good response in the detector fabricated from the crystal taken from the stable growth region; its ({mu}{tau}){sub e} value was 2.6 x 10{sup -3} cm{sup 2}/V, which is acceptable for thin detectors, including for applications in medicine.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Point Defect Characterization in CdZnTe

Measurements of the defect levels and performance testing of CdZnTe detectors were performed by means of Current Deep Level Transient Spectroscopy (I-DLTS), Transient Charge Technique (TCT), Current versus Voltage measurements (I-V), and gamma-ray spectroscopy. CdZnTe crystals were acquired from different commercial vendors and characterized for their point defects. I-DLTS studies included measurements of defect parameters such as energy levels in the band gap, carrier capture cross sections, and defect densities. The induced current due to laser-generated carriers was measured using TCT. The data were used to determine the transport properties of the detectors under study. A good correlation was found between the point defects in the detectors and their performance.

36 MATERIALS SCIENCE↗

Observation of Gamma Irradiation-Induced Suppression of Reversed Annealing in Neutron Irradiated MCZ Si Detectors

For the development of radiation-hard Si detectors for the SiD BeamCal program for the future ILC (International Linear Collider), n-type MCZ Si detectors have been irradiated first by fast neutrons to flueneces of 1.5 x 1014 and 3 x 1014 neq/cm2, and then by gamma up to 500 Mrad. The motivation of this mixed radiation project is to develop a Si detector that can utilize the gamma/electron radiation that exists in the ICL radiation environment, which also includes neutrons. By using the positive space charge (SC) created by gamma radiation in MCZ Si detectors, one can cancel the negative space charge created by neutrons, thus reducing the overall/net space charge density and therefore the full depletion voltage of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗