Search NASA⌕ Search

Engineering topics

Guo, B

Publications and source records attributed to Guo, B.

SU-F-T-347: An Absolute Dose-Volume Constraint Based Deterministic Optimization Framework for Multi-Co60 Source Focused Radiotherapy

Purpose: Treatment plan optimization in multi-Co60 source focused radiotherapy with multiple isocenters is challenging, because dose distribution is normalized to maximum dose during optimization and evaluation. The objective functions are traditionally defined based on relative dosimetric distribution. This study presents an alternative absolute dose-volume constraint (ADC) based deterministic optimization framework (ADC-DOF). Methods: The initial isocenters are placed on the eroded target surface. Collimator size is chosen based on the area of 2D contour on corresponding axial slice. The isocenter spacing is determined by adjacent collimator sizes. The weights are optimized by minimizing the deviation from ADCs using the steepest descent technique. An iterative procedure is developed to reduce the number of isocenters, where the isocenter with lowest weight is removed without affecting plan quality. The ADC-DOF is compared with the genetic algorithm (GA) using the same arbitrary shaped target (254cc), with a 15mm margin ring structure representing normal tissues. Results: For ADC-DOF, the ADCs imposed on target and ring are (D100>10Gy, D50,10, 0<12Gy, 15Gy and 20Gy) and (D40<10Gy). The resulting D100, 50, 10, 0 and D40 are (9.9Gy, 12.0Gy, 14.1Gy and 16.2Gy) and (10.2Gy). The objectives of GA are to maximize 50% isodose target coverage (TC) while minimize the dose delivered to the ring structure, which results in 97% TC and 47.2% average dose in ring structure. For ADC-DOF (GA) techniques, 20 out of 38 (10 out of 12) initial isocenters are used in the final plan, and the computation time is 8.7s (412.2s) on an i5 computer. Conclusion: We have developed a new optimization technique using ADC and deterministic optimization. Compared with GA, ADC-DOF uses more isocenters but is faster and more robust, and achieves a better conformity. For future work, we will focus on developing a more effective mechanism for initial isocenter determination.

60 APPLIED LIFE SCIENCES↗

SU-F-T-620: Development of a Convolution/Superposition Dose Engine for CyberKnife System

Purpose: Current CyberKnife treatment planning system (TPS) provided two dose calculation algorithms: Ray-tracing and Monte Carlo. Ray-tracing algorithm is fast, but less accurate, and also can’t handle irregular fields since a multi-leaf collimator system was recently introduced to CyberKnife M6 system. Monte Carlo method has well-known accuracy, but the current version still takes a long time to finish dose calculations. The purpose of this paper is to develop a GPU-based fast C/S dose engine for CyberKnife system to achieve both accuracy and efficiency. Methods: The TERMA distribution from a poly-energetic source was calculated based on beam’s eye view coordinate system, which is GPU friendly and has linear complexity. The dose distribution was then computed by inversely collecting the energy depositions from all TERMA points along 192 collapsed-cone directions. EGSnrc user code was used to pre-calculate energy deposition kernels (EDKs) for a series of mono-energy photons The energy spectrum was reconstructed based on measured tissue maximum ratio (TMR) curve, the TERMA averaged cumulative kernels was then calculated. Beam hardening parameters and intensity profiles were optimized based on measurement data from CyberKnife system. Results: The difference between measured and calculated TMR are less than 1% for all collimators except in the build-up regions. The calculated profiles also showed good agreements with the measured doses within 1% except in the penumbra regions. The developed C/S dose engine was also used to evaluate four clinical CyberKnife treatment plans, the results showed a better dose calculation accuracy than Ray-tracing algorithm compared with Monte Carlo method for heterogeneous cases. For the dose calculation time, it takes about several seconds for one beam depends on collimator size and dose calculation grids. Conclusion: A GPU-based C/S dose engine has been developed for CyberKnife system, which was proven to be efficient and accurate for clinical purpose, and can be easily implemented in TPS.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-08: LINAC Head Geometry Modeling for Cyber Knife System

Purpose: Knowledge of the LINAC head information is critical for model based dose calculation algorithms. However, the geometries are difficult to measure precisely. The purpose of this study is to develop linac head models for Cyber Knife system (CKS). Methods: For CKS, the commissioning data were measured in water at 800mm SAD. The measured full width at half maximum (FWHM) for each cone was found greater than the nominal value, this was further confirmed by additional film measurement in air. Diameter correction, cone shift and source shift models (DCM, CSM and SSM) are proposed to account for the differences. In DCM, a cone-specific correction is applied. For CSM and SSM, a single shift is applied to the cone or source physical position. All three models were validated with an in-house developed pencil beam dose calculation algorithm, and further evaluated by the collimator scatter factor (Sc) correction. Results: The mean square error (MSE) between nominal diameter and the FWHM derived from commissioning data and in-air measurement are 0.54mm and 0.44mm, with the discrepancy increasing with cone size. Optimal shift for CSM and SSM is found to be 9mm upward and 18mm downward, respectively. The MSE in FWHM is reduced to 0.04mm and 0.14mm for DCM and CSM (SSM). Both DCM and CSM result in the same set of Sc values. Combining all cones at SAD 600–1000mm, the average deviation from 1 in Sc of DCM (CSM) and SSM is 2.6% and 2.2%, and reduced to 0.9% and 0.7% for the cones with diameter greater than 15mm. Conclusion: We developed three geometrical models for CKS. All models can handle the discrepancy between vendor specifications and commissioning data. And SSM has the best performance for Sc correction. The study also validated that a point source can be used in CKS dose calculation algorithms.

60 APPLIED LIFE SCIENCES↗

Indirect measurements of reactions in hot p-p chain and CNO cycles

Several reactions have been experimentally studied, including the {sup 12}N(d,n){sup 13}O and the ones induced by the {sup 3}He+{sup 12}C entrance channel. The former was carried out at the CRIB facility of University of Tokyo, aiming to indirectly determine the astrophysical reaction rates of the {sup 12}N(p,{gamma}){sup 13}O reaction. For the {sup 3}He+{sup 12}C entrance channel, many excited states of several nuclei are populated and the angular distribution of each state is being analyzed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photonic band structures of one-dimensional photonic crystals doped with plasma

The photonic band structures (PBSs) of oblique incidence propagation in one-dimensional plasma-doped photonic crystals (PCs) are investigated carefully. When the lattice constant of plasma-doped PCs is less than the incident wavelength, the PC becomes anisotropic. Therefore, the dielectric constant of PC is converted into a complex tensor dielectric constant. This determines the PBSs of PCs. In the present paper, one-dimensional PCs are taken as an example to study both normal and absorption PBSs. Using both the effective medium approximation and the transfer matrix method, we can derive the dispersion relation for PCs. The dependence of the plasma filling factor on the effective dielectric constant and PBSs is calculated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Indirect measurement of nuclear reactions of astrophysical interest

Systematic indirect measurements of nuclear astrophysical reactions using the unstable ion beam facility GIRAFFE in CIAE were performed. We have measured the angular distributions of transfer reactions, such as {sup 8}Li(d,p){sup 9}Li, {sup 8}Li(d,n){sup 9}Be and {sup 8}Li(p,d){sup 7}Li in inverse kinematics, and derived the astrophysical S-factors or reaction rates for {sup 8}Li(n,gamma){sup 9}Li and {sup 8}Li(p,gamma){sup 9}Be by using asymptotic normalization coefficient (ANC) or spectroscopic factor methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Frontiers in Assessing the Role of Chemical Speciation And Natural Attenuation on the Bioavailability of Contaminants in the Terrestrial Environment

It has long been recognized that contaminants interact with the solid soil phase via a series of sorption-desorption (all chemicals) and precipitation-dissolution (polar and ionic compounds) reactions including physical migration into micropores and diffusion into the solid phase (see Chapter 2). Until recently the extent of such interactions and the binding with different solid pools was established via a series of chemical extractions (see Chapter 20) and a combination of instrumental techniques. However, none of these techniques provide a true indication of the speciation of contaminants on or in solid minerals and organics. The last decade has witnessed the emergence of tools that provide an assessment of the speciation and attenuation of chemicals at molecular level. In this chapter we provide an overview of the current state-of-the-art for assessing speciation and attenuation of contaminants in the terrestrial environment. Given that speciation and attenuation influence chemical bioavailability, we devote part of this chapter to the application of isotopic dilution techniques to bioavailability assessment. We have not attempted to be exhaustive but rather to highlight a number of studies in sufficient detail so that the reader will be provided with an insight as to whether such approaches are applicable to their field of endeavor and what the realistic outcomes might be.

54 ENVIRONMENTAL SCIENCES↗

Modeling coal combustion behavior in an ironmaking blast furnace raceway: model development and applications

A numerical model has been developed and validated for the investigation of coal combustion phenomena under blast furnace operating conditions. The model is fully three-dimensional, with a broad capacity to analyze significant operational and equipment design changes. The model was used in a number of studies, including: Effect of cooling gas type in coaxial lance arrangements. It was found that oxygen cooling improves coal burnout by 7% compared with natural gas cooling under conditions that have the same amount of oxygen enrichment in the hot blast. Effect of coal particle size distribution. It was found that during two similar periods of operation at Port Kembla's BF6, a difference in PCI capability could be attributed to the difference in coal size distribution. Effect of longer tuyeres. Longer tuyeres were installed at Port Kembla's BF5, leading to its reline scheduled for March 2009. The model predicted an increase in blast velocity at the tuyere nose due to the combustion of volatiles within the tuyere, with implications for tuyere pressure drop and PCI capability. Effect of lance tip geometry. A number of alternate designs were studied, with the best-performing designs promoting the dispersion of the coal particles. It was also found that the base case design promoted size segregation of the coal particles, forcing smaller coal particles to one side of the plume, leaving larger coal particles on the other side. 11 refs., 15 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗