Search NASA⌕ Search

Engineering topics

Guo, Liang

Publications and source records attributed to Guo, Liang.

At least 37 records · Page 2

Experimental demonstration of laser to x-ray conversion enhancements with low density gold targets

The enhancement of laser to x-ray conversion efficiencies using low density gold targets [W. L. Shang, J. M. Yang, and Y. S. Dong, Appl. Phys. Lett. 102, 094105 (2013)] is demonstrated. Laser to x-ray conversion efficiencies with 6.3% and 12% increases are achieved with target densities of 1 and 0.25 g/cm 3 , when compared with that of a solid gold target (19.3 g/cm 3 ). Experimental data and numerical simulations are in good agreement. Lastly, the enhancement is caused by larger x-ray emission zone lengths formed in low density targets, which is in agreement with the simulation results.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ultrafast carriers dynamics in filled-skutterudites

Carrier dynamics of filled-skutterudites, an important class of thermoelectric materials, is investigated using ultrafast optical spectroscopy. By tuning the wavelength of the probe laser, charge transfers at different electronic energy levels are interrogated. Analysis based on the Kramers-Kronig relation explains the complex spectroscopy data, which is mainly due to band filling caused by photo-excited carriers and free carrier absorption. The relaxation time of hot carriers is found to be about 0.4–0.6 ps, depending on the electronic energy level, and the characteristic time for carrier-phonon equilibrium is about 0.95 ps. These studies of carrier dynamics, which fundamentally determines the transport properties of thermoelectric material, can provide guidance for the design of materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray conversion efficiency and radiation non-uniformity in the hohlraum experiments at Shenguang-III prototype laser facility

The hohlraum radiation properties are studied experimentally by the Shenguang-III prototype laser facility and numerically by the two-dimensional code LARED with the multi-group radiation transfer model. The measured radiation temperature is consistent with the prediction of the simulations in a wide laser energy range, suggesting that the x-ray conversion efficiency is around 75% at the peak radiation temperature. The delicate hohlraum experiments further show that the radiation intensity inside the hohlraum is significantly non-uniform. The measured radiation flux of the hot spot region is over twice higher than that of the re-emitted wall region. Good agreements between the experiments and simulations further demonstrate the validity of the LARED code to study the hohlraum radiation properties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing the hohlraum radiation via one-end driven experiments

A new experiment is designed and performed on the Shenguang III laser facility with the first eight available beams to characterizing the hohlraum radiation, in which the hohlraum with laser entrance holes on both ends is driven through one-end only. The experiment enables us to identify the x-ray radiations originated from the hohlraum reemission wall and high-Z bubble plasmas utilizing their position and spectral characters, which provides a better test on the associated hohlraum models. The total and M-band x-ray radiation fluxes are measured with the flat response x-ray detectors and the filtered M-band x-ray detectors, respectively. Numerical simulations are conducted with the two-dimensional radiation hydrodynamic code LARED-INTEGRATION using the multi-group radiation transfer and/or diffusion models. It is found that the experimentally measured temporal profiles and angular distributions of hohlraum radiation are in good agreement with the predictions of simulation using radiation transfer models, but differ significantly from the results obtained with the multi-group radiation diffusion calculations. We thus note that to accurately represent the hohlraum radiation, a true radiation transfer model is essential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The influence of laser clipped by the laser entrance hole on hohlraum radiation measurement on Shenguang-III prototype

Measuring the x-ray flux exiting the target's laser entrance hole (LEH) is the most common diagnostic that quantifies the x-ray intensity inside the laser-driven hohlraum. However, this signal accounts for only a small portion of the incident laser power and thus is likely to be affected by unwanted x-ray background from non-target area, leading to an overestimation of the hohlraum drive. Unwanted emission might be produced when the laser light is clipped by the LEH (LEH clipping) because of a lack of clearance for laser spot, or with a laser spot comprising of discrete structure, or even with a poor pointing accuracy. Its influence on the hohlraum radiation diagnostic is investigated on Shenguang-III prototype laser facility with the typical 1 ns square pulse. The experiment employed three types of targets to excite the unwanted x-ray background from LEH clipping, unconverted light, and both effects, respectively. This work gives an absolute evaluation of x-ray produced by the LEH clipping, which is measured by flat-response x-ray detectors (FXRD) at multiple view angles. The result indicates that there is little variation in measured emission to various view angles, because the unwanted x-rays are mainly generated at the side face of the LEH lip when laser is obliquely incident. Therefore, the LEH clipping brings more overestimation in hohlraum radiation measurement at larger view angle since the hohlraum LEH as an emitting source viewed by FXRD is decreased as the view angle increases. In our condition, the LEH clipping contributes 2%–3.5% overestimation to the hohlraum flux measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The radiation temperature and M-band fraction inside hohlraum on the SGIII-prototype laser facility

The radiation temperature T{sub R} and M-band fraction f{sub M} inside the vacuum Au hohlraum have been experimentally determined by a shock wave technique and a broadband soft x-ray spectrometer (SXS) on the SGIII-prototype laser facility. From the results of the shock wave technique, T{sub R} is about 202 eV, and f{sub M} is about 9% for the hohlraums driven by a 1 ns flattop pulse of 6 kJ laser energy. The Continuous Phase Plate (CPP) for beam smoothing is applied in the experiment, which increases T{sub R} to 207 eV while has almost no influence on f{sub M}. Comparisons between the results from the two kinds of technologies show that T{sub R} from the shock wave technique is lower than that from SXS whether with CPP or not. However, f{sub M} from the shock wave technique is consistent with that from SXS without CPP, but obviously lower than the SXS's result with CPP. The preheat effect on exterior surface of witness plate is reduced by thicker thickness of witness plate designed for higher laser driven energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The M-band transmission flux of the plastic foil with a coated layer of silicon or germanium

Silicon (Si) and Germanium (Ge) can be used as the dopant in the ablator material for the purpose of reducing preheating in indirect-drive inertial confinement fusion. Their performances in reducing preheating are quite different. A method to evaluate the difference of these two kinds of dopants has been presented in this letter. In the Shenguang-II high power laser facility, the M-band (1.6–4.4 keV) transmission flux of Si-coated plastic (CH) and Ge-coated plastic (CH) has been measured by using the M-band x-ray diode. In the experiment, we find that the Si-coated CH can absorb more M-band x-rays and thus reduce the preheating of the fuel in our experiment condition. By using the radiation hydrodynamic code MULTI-1D, we got the simulation result which was well suited for the experiment. The comparison of their opacities (T{sub e} = 60–100 eV and ρ = 0.1–0.5 g/cm{sup 3}) also shows that the opacity of Si is higher than that of Ge almost in the whole range of 1.6–4.4 keV.

36 MATERIALS SCIENCE↗

Enhanced x-ray emissions from Au-Gd mixture targets ablated by a high-power nanosecond laser

As an important x-ray source, enhancement of x-ray emissions from laser-produced plasmas is imperative for various applications. High-Z Au-Gd mixture targets are proposed to enhance the laser to x-ray conversion efficiency compared to pure Au target. In the experiments, a 1 ns frequency-tripled (351 nm wavelength) laser light was used to obtain an intensity of 3×10{sup 14} W/cm{sup 2} on the targets. The x-ray spectra, total absolute x-ray emissions of all space, M-band fraction and backscattering from pure Au and Au-Gd mixture have been measured, respectively. It is shown that the absolute laser to x-ray conversion efficiency for the Au-Gd mixture containing 60% gold by atom is 47.7%, which has a 15% enhancement compared with that of the pure Au target. The experimental results are consistent with the radiation hydrodynamic simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The impact of low-Z impurities on x-ray conversion efficiency from laser-produced plasmas of low-density gold foam targets

It is an important approach to improve the x-ray conversion efficiency of laser-ablated high-Z plasmas by using low initial density materials for various applications. However, unavoidable low-Z impurities in the manufacture process of low-density high-Z foam targets will depress this effect. A general easy-to-use analytical model based on simulations was developed to evaluate the quantitative impact of impurities within the gold foam target on laser to x-ray conversion efficiency. In addition, the x-ray conversion efficiencies of 1 g/cm{sup 3} gold foams with two different initial contents of impurities were experimentally investigated. Good agreements have been achieved between the model results and experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nucleotide-induced asymmetry within ATPase activator ring drives σ54-RNAP interaction and ATP hydrolysis

It is largely unknown how the typical homomeric ring geometry of ATPases associated with various cellular activities enables them to perform mechanical work. Small-angle solution X-ray scattering, crystallography, and electron microscopy (EM) reconstructions revealed that partial ATP occupancy caused the heptameric closed ring of the bacterial enhancer-binding protein (bEBP) NtrC1 to rearrange into a hexameric split ring of striking asymmetry. The highly conserved and functionally crucial GAFTGA loops responsible for interacting with σ54–RNA polymerase formed a spiral staircase. We propose that splitting of the ensemble directs ATP hydrolysis within the oligomer, and the ring's asymmetry guides interaction between ATPase and the complex of σ54 and promoter DNA. Similarity between the structure of the transcriptional activator NtrC1 and those of distantly related helicases Rho and E1 reveals a general mechanism in homomeric ATPases whereby complex allostery within the ring geometry forms asymmetric functional states that allow these biological motors to exert directional forces on their target macromolecules.

Sysoeva, Tatyana A.↗

Deconvolving the temporal response of photoelectric x-ray detectors for the diagnosis of pulsed radiations

Based on the conjugate gradient method, a simple algorithm is presented for deconvolving the temporal response of photoelectric x-ray detectors (XRDs) to reconstruct the resolved time-dependent x-ray fluxes. With this algorithm, we have studied the impact of temporal response of XRD on the radiation diagnosis of hohlraum heated by a short intense laser pulse. It is found that the limiting temporal response of XRD not only postpones the rising edge and peak position of x-ray pulses but also smoothes the possible fluctuations of radiation fluxes. Without a proper consideration of the temporal response of XRD, the measured radiation flux can be largely misinterpreted for radiation pulses of a hohlraum heated by short or shaped laser pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase transitions in the assembly of multivalent signalling proteins

Cells are organized on length scales ranging from angstrom to micrometers. However, the mechanisms by which angstrom-scale molecular properties are translated to micrometer-scale macroscopic properties are not well understood. Here we show that interactions between diverse synthetic, multivalent macromolecules (including multi-domain proteins and RNA) produce sharp liquid-liquid-demixing phase separations, generating micrometer-sized liquid droplets in aqueous solution. This macroscopic transition corresponds to a molecular transition between small complexes and large, dynamic supramolecular polymers. The concentrations needed for phase transition are directly related to the valency of the interacting species. In the case of the actin-regulatory protein called neural Wiskott-Aldrich syndrome protein (N-WASP) interacting with its established biological partners NCK and phosphorylated nephrin1, the phase transition corresponds to a sharp increase in activity towards an actin nucleation factor, the Arp2/3 complex. The transition is governed by the degree of phosphorylation of nephrin, explaining how this property of the system can be controlled to regulatory effect by kinases. The widespread occurrence of multivalent systems suggests that phase transitions may be used to spatially organize and biochemically regulate information throughout biology.

59 BASIC BIOLOGICAL SCIENCES↗

Activation of p115-RhoGEF Requires Direct Association of G[alpha subscript 13] and the Dbl Homology Domain

RGS-containing RhoGEFs (RGS-RhoGEFs) represent a direct link between the G{sub 12} class of heterotrimeric G proteins and the monomeric GTPases. In addition to the canonical Dbl homology (DH) and pleckstrin homology domains that carry out the guanine nucleotide exchange factor (GEF) activity toward RhoA, these RhoGEFs also possess RGS homology (RH) domains that interact with activated {alpha} subunits of G{sub 12} and G{sub 13}. Although the GEF activity of p115-RhoGEF (p115), an RGS-RhoGEF, can be stimulated by G{alpha}{sub 13}, the exact mechanism of the stimulation has remained unclear. Using combined studies with small angle x-ray scattering, biochemistry, and mutagenesis, we identify an additional binding site for activated G{alpha}{sub 13} in the DH domain of p115. Small angle x-ray scattering reveals that the helical domain of G{alpha}{sub 13} docks onto the DH domain, opposite to the surface of DH that binds RhoA. Mutation of a single tryptophan residue in the {alpha}3b helix of DH reduces binding to activated G{alpha}{sub 13} and ablates the stimulation of p115 by G{alpha}{sub 13}. Complementary mutations at the predicted DH-binding site in the {alpha}B-{alpha}C loop of the helical domain of G{alpha}{sub 13} also affect stimulation of p115 by G{alpha}{sub 13}. Although the GAP activity of p115 is not required for stimulation by G{alpha}{sub 13}, two hydrophobic motifs in RH outside of the consensus RGS box are critical for this process. Therefore, the binding of G{alpha}{sub 13} to the RH domain facilitates direct association of G{alpha}{sub 13} to the DH domain to regulate its exchange activity. This study provides new insight into the mechanism of regulation of the RGS-RhoGEF and broadens our understanding of G protein signaling.

59 BASIC BIOLOGICAL SCIENCES↗