Search NASA⌕ Search

Engineering topics

Guohua, Cao

Publications and source records attributed to Guohua, Cao.

Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray

Purpose: Carbon nanotube (CNT) based field emission x-ray source technology has recently been investigated for diagnostic imaging applications because of its attractive characteristics including electronic programmability, fast switching, distributed source, and multiplexing. The purpose of this article is to demonstrate the potential of this technology for high-resolution prospective-gated cardiac micro-CT imaging. Methods: A dynamic cone-beam micro-CT scanner was constructed using a rotating gantry, a stationary mouse bed, a flat-panel detector, and a sealed CNT based microfocus x-ray source. The compact single-beam CNT x-ray source was operated at 50 KVp and 2 mA anode current with 100 {mu}mx100 {mu}m effective focal spot size. Using an intravenously administered iodinated blood-pool contrast agent, prospective cardiac and respiratory-gated micro-CT images of beating mouse hearts were obtained from ten anesthetized free-breathing mice in their natural position. Four-dimensional cardiac images were also obtained by gating the image acquisition to different phases in the cardiac cycle. Results: High-resolution CT images of beating mouse hearts were obtained at 15 ms temporal resolution and 6.2 lp/mm spatial resolution at 10% of system MTF. The images were reconstructed at 76 {mu}m isotropic voxel size. The data acquisition time for two cardiac phases was 44{+-}9 min. The CT values observed within the ventricles and the ventricle wall were 455{+-}49 and 120{+-}48 HU, respectively. The entrance dose for the acquisition of a single phase of the cardiac cycle was 0.10 Gy. Conclusions: A high-resolution dynamic micro-CT scanner was developed from a compact CNT microfocus x-ray source and its feasibility for prospective-gated cardiac micro-CT imaging of free-breathing mice under their natural position was demonstrated.

60 APPLIED LIFE SCIENCES↗

Multibeam field emission x-ray system with half-scan reconstruction algorithm

Purpose: In this article, the authors propose a multibeam field emission x-ray (MBFEX) system along with a half-scan fan-beam reconstruction algorithm. Methods: The proposed system consists of a linear CNT-based MBFEX source array, a single large area detector that is divided into same number of segments as the number of x-ray beams, a multihole collimator that aligns each beam with a corresponding detector segment, and a sample rotation stage. The collimator is placed between the source and the object to restrict the x-ray radiations through the target object only. In this design, all the x-ray beams are activated simultaneously to provide multiple projection views of the object. The detector is virtually segmented and synchronized with the x-ray exposure and the physiological signals when gating is involved. The transmitted x-ray intensity from each beam is collected by the corresponding segment on the detector. After each exposure, the object is rotated by a step angle until sufficient data set is collected. The half-scan reconstruction formula for MBFEX system is derived from the conventional filtered backprojection algorithm. To demonstrate the advantages of the system and method in reducing motion artifacts, the authors performed simulations with both standard and dynamic Shepp-Logan phantoms. Results: The numerical results indicate that the proposed multibeam system and the associated half-scan algorithm can effectively reduce the scanning time and improve the image quality for a time-varying object. Conclusions: The MBFEX technique offers an opportunity for the innovation of multisource imaging system.

60 APPLIED LIFE SCIENCES↗

Temporal multiplexing radiography for dynamic x-ray imaging

All current x-ray imaging devices acquire images sequentially, one at a time. Using a spatially distributed multibeam x-ray source we recently demonstrated the feasibility for multiplexing x-ray imaging, which can significantly increase the data collection speed. Here we present a general methodology for dynamic x-ray imaging of an object in cyclic motion with temporal multiplexing. Compared to the conventional sequential imaging technique, where 2N-1 phase images are required and N exposures are needed for a single phase image, a temporal multiplexing of dimension 2N-1 can reduce the imaging time by a factor of N while maintaining the temporal resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray phase contrast imaging: Transmission functions separable in cylindrical coordinates

A Fresnel-Kirchhoff integral can be used to calculate x-ray phase contrast images when the transmission function is known. Here expressions for image intensity are derived for objects with axial symmetry for an x-ray source with non-vanishing dimensions. An expression for the image intensity is given for an x-ray source whose intensity distribution is described by a Gaussian function, from which an expression for the limiting case of a point source of radiation is found. The expressions for image intensity are evaluated for cases where the magnification is substantially greater than one, as would be employed in biological imaging. Experiments using a microfocus x-ray tube and charge coupled device camera are reported to determine the capability of the method for imaging small spherical objects, such as gold particles, which might find application as contrast agents in biomedical imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗