Search NASA⌕ Search

Engineering topics

Gupta, Vijay

Publications and source records attributed to Gupta, Vijay.

Development of a rate-based ENRTL-RK process model for a water-lean solvent

Advanced water-lean solvents (WLS) for post-combustion CO2 capture offer several advantages over the aqueous amine solvents . WLS have lower parasitic energy penalty, lower corrosion, lower temperature and high-pressure CO2 regeneration leading to lower cost of CO2 capture. RTI International, with funding from the US Department of Energy, has been developing its novel water-lean solvent, that has shown specific reboiler duty of 2.3 GJ/t-CO2 at the 60-kWe pilot testing unit (Tiller Plant, SINTEF, Norway) and 2.6 GJ/t-CO2 at the engineering scale testing system (12 MWe) at the Technology Centre Mongstad (TCM) in Norway. All heat duties, including the one from TCM testing, were consistent with Aspen Plus modeling of the specific configuration of each test plant. This work focuses on the development of a detailed process model using in-house laboratory measurements and process data at pilot scale. The eNTRL-RK model used in this work is based on an unsymmetric activity coefficient model with the reference states chosen to be pure liquids for solvents and ideal dilute solution at unit solute molality (resulting in activity coefficient of unity at infinite dilution) for electrolytes. It uses the Redlich-Kwong equation of state for vapor phase properties and Henry’s law for solubility of supercritical gases. The model was validated using process data from the pilot-scale campaign at the Tiller plant, and the engineering scale test campaign at TCM. Data on CO2 capture rate, absorber, and regenerator temperature profiles and specific reboiler duties from two different test campaigns at Tiller and TCM, were used to further refine and validate the model and the model compares favorably to experimental data. The validation results against TCM campaign will be presented in this work.

CO2 capture↗

A high fidelity and user-friendly equation-oriented optimization model for carbon capture using a novel water-lean solvent

Research Triangle Institute (RTI) International and SLB have developed a novel water-lean solvent technology for carbon capture, demonstrating low specific reboiler duty (SRD) values at capture rates exceeding 90%. At the Technology Centre Mongstad (TCM) pilot plant, the technology achieved an SRD of 2.55 GJ/t-CO2 at 95% capture, utilizing an intercooler and a 5°C temperature approach in the lean/rich solvent cross exchanger. To meet varying carbon capture targets for Front End Engineering and Design (FEED) studies and to enable real-time optimization and advanced process control, an efficient optimization model is required. This model needs to minimize energy demand for a given capture rate and determine optimal operating parameters in response to fluctuating flue gas conditions. While an existing Aspen Plus simulation model, developed by RTI and SLB, accurately matches TCM plant data, its sequential modular (SM) strategy is too slow for real-time applications due to recycle streams and tight heat integration inherent in solvent-based carbon capture processes. Although an equation-oriented (EO) modeling strategy is more suitable for optimizing these processes, its adoption has been limited by several factors: feature limitations in Aspen Plus EO mode (e.g., lack of balance block support), a less user-friendly interface for variable identification and loop solving, complex troubleshooting of convergence issues, and the necessity for accurate initial values.

carbon capture↗

Methods and systems for emissions control in solvent-based CO2 capture processes using CO2

A method with corresponding systems for reducing emission of amines to the atmosphere. The method includes a a) introducing a gas containing CO 2 into an absorber; b) flowing the flue gas through an absorber having an absorbent with a water-lean solution having less than 50% water and one or more amines, with the absorbent capturing the CO 2 and forming a reduced CO 2 content gas having a baseline CO 2 content; and c) washing the reduced CO 2 content gas in a wash column with a wash solution comprising carbonic acid formed by addition of gaseous CO 2 into the wash solution. In this method, the washing removes the amines from the reduced CO 2 content gas and produces a reduced amine content gas exiting from the wash column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Lab-scaled performance evaluation of novel water-lean solvents for post combustion CO 2 capture

Here, this work focuses on demonstrating the energetic performance and operational reliability in a continuous system of RTI's water-lean solvents for post-combustion CO 2 capture applications. RTI's Non-Aqueous Solvent, NAS-1A was subjected to 100 h of continuous, CO 2 capture and regeneration operation using a Lab-scale Gas Absorption System (LsGAS) while the CO 2 capture efficiency, mass balance, and total energy inputs were monitored. Throughout the test period, NAS-1A demonstrated stable operation with 90% CO 2 capture while requiring about 15% lower total energy input for solvent regeneration compared to 30 wt% monoethanolamine (MEA) solution. The use of a slipstream of CO 2 -rich solvent from the absorber sump reduced the regenerated CO 2 temperature before the gas was further cooled by the overhead condenser at the top of the desorber. The rich-split setup combined with a wash section may be an effective approach to remove water and solvent vapor from the regenerated CO 2 as well as to recover heat at the top of the desorber. NAS-1B was later developed and included a modifier component that lowers the heat of CO 2 absorption and reduces the vapor pressure of the amine component. The total energy inputs for 90% CO 2 capture with NAS-1B was found to be 25% less than that of the MEA. A gas chromatograph was used to monitor the amine concentration in the gas leaving the absorber wash section. It was found that under similar operating conditions, the presence of the modifier in NAS-1B reduces the amine in the absorber off-gas from 143 ppm in NAS-1A to 20 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aerosol emissions from water-lean solvents for post-combustion CO 2 capture

Advanced water-lean solvents (WLS) for post-combustion CO 2 capture have been gaining interest due to their ability to reduce the parasitic penalty from energy needed for solvent regeneration. Commercial implementation of these novel CO 2 capture technologies hinges on successful control of amine emissions. RTI conducted a parametric study of fundamental and operational variables influence on overall amine aerosol and vapor emissions from our water-lean solvent eCO 2 Sol™ using our 6-kW equivalent bench-scale gas absorption system. The parametric testing used a simulated flue gas with 15 % CO 2 , 2.3–4.2 % H 2 O, and 0–6 ppm sulfite (SO 3 ) to examine the impact of the presence of aerosols to the capture performance and amine emissions from the system. The SO 3 reacts with water in the flue gas to create H 2 SO 4 , which forms liquid aerosol droplets and provide nucleation sites for growth of aerosols. Scanning Mobility Particle Sizer and Aerodynamic Particle Sizer instruments monitored the aerosol particle size distribution. Parametric testing results suggested that the presence of the aerosols in the flue gas could increase the overall amine emissions by 10X compared to the baseline emissions from WLS’s vapor pressure. Principal component analysis (PCA) and projection to latent squares (PLS) developed models to predict the aerosol-based amine emissions from process data. The predictive PLS model had a correlation coefficient (Q 2 ) of 0.92 and could predict the aerosol-based emissions from the NAS process with ±15 % accuracy (average absolute deviation, AAD). The PLS regression model also identified key variables affecting aerosol-based emissions from WLS.

42 ENGINEERING↗

Experimental Study of a Hydrophobic Solvent for Natural Gas Sweetening Based on the Solubility and Selectivity for Light Hydrocarbons (CH 4 , C 2 H 6 ) and Acid Gases (CO 2 and H 2 S) at 298–353 K

The Henry’s constants of H 2 S, CO 2 , CH 4 , and C 2 H 6 in a hydrophobic solvent (HPS) were determined to evaluate the potential use of the HPS for natural gas sweetening applications. The gas solubilities were evaluated at atmospheric pressure in the temperature range of 298-353 K. The Henry’s constant of N 2 O in the HPS was also determined and used to differentiate the physical absorption of the acid gases from the chemical absorption. The temperature-dependent Henry’s constant correlations of these gases were developed and used to determine the separation performance of the HPS in a simple absorber process simulation. Here, the simulation results suggest that HPS can remove acid contaminants and achieve the targeted quality of natural gas for liquid natural gas (LNG) production. The HPS exhibits rather high CH 4 and C 2 H 6 absorption, and consequently, has low acid gas selectivity compared to the commercially available physical solvent. the acid gas selectivity can be optimized with the inclusion a limited quantity of a hydrophilic component to enhance H 2 S and CO 2 while still minimizing the hydrocarbons solubilities.

03 NATURAL GAS↗

Distributed Energy Management for Networked Microgrids Using Online ADMM With Regret

We propose a distributed algorithm for online energy management in networked microgrids with a high penetration of distributed energy resources (DERs). A high penetration of DERs introduces high uncertainty of power generation to the microgrids. In general, the state-of-the-art forecasting for non-dispatchable DERs such as solar energy is not sufficiently accurate, which results in inaccurate energy scheduling. To address the high uncertainty issue in the networked microgrids, we propose an online energy management based on the online alternating direction method of multipliers algorithm with the past power generation information from the DERs. The online algorithm provides less conservative schedule than the robust optimization-based approach. The effectiveness of the proposed algorithm is verified by various numerical examples.

alternating direction method of multipliers↗

Benefits of Integration of Aerojet Rocketdyne and RTI Advanced Gasification Technologies for Hydrogen-Rich Syngas Production

The key objective for this project was to evaluate the potential to achieve substantial reductions in the production cost of H 2 -rich syngas via coal gasification with near-zero emissions due to the cumulative and synergistic benefits realized when multiple advanced technologies are integrated into the overall conversion process. In this project, Aerojet Rocketdyne’s (AR’s) advanced gasification technology (currently being offered as R-GAS™) and RTI International’s (RTI’s) advanced warm syngas cleanup technologies were evaluated via a number of comparative techno-economic case studies. AR’s advanced gasification technology consists of a dry solids pump and a compact gasifier system. Based on the unique design of this gasifier, it has been shown to reduce the capital cost of the gasification block by between 40 and 50%. At the start of this project, actual experimental work had been demonstrated through pilot plant systems for both the gasifier and dry solids pump. RTI’s advanced warm syngas cleanup technologies consist primarily of RTI’s Warm Gas Desulfurization Process (WDP) technology, which effectively allows decoupling of the sulfur and CO 2 removal allowing for more flexibility in the selection of the CO 2 removal technology, plus associated advanced technologies for direct sulfur recovery and water gas shift (WGS). WDP has been demonstrated at pre-commercial scale using an activated amine carbon dioxide recovery process which would not have been possible if a majority of the sulfur had not been removed from the syngas by WDP. This pre-commercial demonstration of RTI’s advanced warm syngas cleanup system was conducted in parallel to the activities on this project. The technical data and cost information from this pre-commercial demonstration were extensively used in this project during the techno-economic analysis. With this project, both of RTI’s advanced WGS technologies were investigated. Because RT’s advanced fixed-bed WGS (AFWGS) process was successfully implemented in the WDP pre-commercial demonstration test mentioned above, this technology was used as part of RTI’s advanced warm syngas technology package for the techno-economic analyses for this project. RTI’s advanced transport-reactor-based WGS (ATWGS) process was still conceptual at the start of this project, but one of the tasks for this project was to evaluate the technical feasibility of this technology. In each of the three application-based comparison studies conducted as part of this project, the reference case was based on an existing Department of Energy National Energy Technology Laboratory (DOE/NETL) system study. Each of these references cases used existing commercial technology and the system resulted in > 90% carbon capture. In the comparison studies for the use of the hydrogen-rich syngas generated in either an Integrated Gasification Combined Cycle (IGCC) or a Coal-to-Methanol (CTM) plant, the comparison cases consisted of the reference case, a case with the integration of each individual advanced technology (either AR or RTI), and finally a case with the integration of all the advanced technologies (AR and RTI combined). In the Coal-to-Liquids (CTL) comparison study, the comparison study consisted of only three cases, which included a reference case, a case with just RTI’s advanced syngas cleaning technology, and a case with AR’s and RTI’s advanced technologies. The results from these comparison studies showed that the integration of the advanced technologies did result in substantial benefits, and by far the greatest benefits were achieved for cases integrating all the advanced technologies. For the IGCC study, the fully integrated case resulted in a 1.4% net efficiency improvement, an 18% reduction in capital cost per kW of capacity, a 12% reduction in the operating cost per kWh, and a 75–79% reduction in sulfur emissions. For the CTM case, the fully integrated plant resulted in a 22% reduction in capital cost, a 13% reduction in operating costs, a > 99% net reduction in sulfur emissions, and a reduction of 13–15% in CO 2 emissions. Because the capital cost represents over 60% of the methanol Required Selling Price (RSP), the significant reduction in the capital cost for the advanced technology case resulted in an 18% reduction in methanol RSP. For the CTL case, the fully integrated plant resulted in a 16% reduction in capital cost, which represented a 13% reduction in diesel RSP. Finally, the technical feasibility analysis of RTI’s ATWGS process demonstrated that a fluid-bed catalyst with sufficient attrition resistance and WGS activity could be made and that the process achieved about a 24% reduction in capital cost compared to a conventional fixed-bed commercial process.

08 HYDROGEN↗

Adhesion measurement of highly-ordered TiO 2 nanotubes on Ti-6Al-4V alloy

Self-assembled nanotubular arrays on Ti alloys could be used for more effective implantable devices in various medical approaches. In the present work, the adhesion of TiO 2 nanotubes (TiO 2 NTs) on Ti-6Al-4V (Ti64) was investigated by laser spallation and scratch test techniques. At first, electrochemical anodization was performed in an ammonium fluoride solution dissolved in a 90:10 ethane-1,2-diol (ethylene glycol) and water solvent mixture. This process was performed at room temperature (23 °C) at a steady potential of 60 V for 1 h. Next, the TiO 2 nanotubes layer was heat-treated to improve the adhesion of the coating. The formation of self-organized TiO 2 nanotubes as well as the microstructural evolution, are strongly dependent on the processing parameters and subsequent annealing. From microscopic analysis, highly oriented arrays of TiO 2 nanotubes were grown by thermal treatment for 90 min at 500 °C. Further heat treatment above 500 °C led to the detachment of the nanotubes and the complete destruction of the nanotubes occurred at temperature above 700 °C. Scratch test analysis over a constant scratch length (1000 μm) indicated that the failure point was shifted from 247.4 to 557.9 μm while the adhesion strength was increased from ~862 to ~1814 mN after annealing at 500 °C. Finally, the adhesion measurement determined by laser spallation technique provided an intrinsic adhesion strength of 51.4 MPa for the TiO 2 nanotubes on the Ti64 substrate.

36 MATERIALS SCIENCE↗