PRELIMINARY RESULTS OF MAGNETIC AND TEMPERATURE MAP SYSTEM FOR 3 GHz SUPERCONDUCTING RADIO FREQUENCY CAVITIES
Superconducting radio frequency (SRF) cavities are fundamental building blocks of modern particle accelerators. A surface resistance in the tens of nanoOhm range is achieved when cooling these cavities to liquid helium temperature, ~2 - 4 K. One of the leading sources of residual losses in SRF cavities is trapped magnetic flux. Flux trapping mechanism depends on different surface preparations and cool-down conditions. We have designed, developed and commissioned a combined magnetic and temperature mapping system using anisotropic magneto-resistance sensors and carbon resistors, respectively, to study the flux trap mechanism in 3 GHz single-cell niobium cavities. In this contribution, we will describe the experimental apparatus and present preliminary test results.