Search NASA⌕ Search

Engineering topics

Haddadi, Aboutaleb

Publications and source records attributed to Haddadi, Aboutaleb.

IBR Bulk System Protection Issues and Modeling Challenges

Issue to be Address: Difficulty in predicting Inverter (IBR) generation dynamic response characteristics. Main challenges are unavailability of proprietary control details for modeling and the aggregate mixed IBRs with different dynamic response characteristics all contributing during system faults. Framework for Discussion: Identifying issues by sharing experience Reviewing options to improve IBR modeling accuracy, computation speed, use of test results. Presenting related research by EPRI and PG&E (DOE project) Desired Outcomes: Provide technical update for participants Get feedback and suggestions for ongoing research Improve research collaboration

IBR, Protection Challenges, dynamic response, IBR ↗

Protection of 100% Inverter-dominated Power Systems with Grid-Forming Inverters and Protection Relays – Gap Analysis and Expert Interviews

This report summarizes a gap analysis resulting from a literature review and expert interviews conducted by subject matter experts from Sandia National Laboratory, Siemens, and the Electric Power Research Institute (EPRI) in Spring 2023. The gap analysis consists of two main parts: The fault-ride through (FRT) behavior of grid-forming (GFM) inverter-based resources (IBR) and the response of state-of-the-art protection relays to the fault currents and voltages from GFM IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementing a Hardware Testbed Using 3-Level ANPC Software Defined Inverters for Fault Analysis of a Transmission Network

In this paper, we propose the implementation of a hardware testbed using 3-level active neutral point clamped (ANPC) software-defined inverters for fault analysis. A test case transmission network equipped with two grid forming (GFM) inverters and four resistive loads is considered in this research. Firstly, grid forming control laws including PI feedback control and droop control are implemented to operate the inverters in parallel. Then, we implement a fault ride-through (FRT) logic and perform a simulation of the test system by applying a three-phase fault. Simulation results show the effectiveness of the fault recovery algorithm upon clearance of the fault. Finally, a 3-level ANPC software-defined inverter is programmed with required control laws and characterized through various lab experiments.

3-level ANPC inverter↗

PV and Dynamic Load Modeling Update

This report documents the PV and dynamic load modeling update for transient stability, EMT, harmonics, and short circuit analyses during budget period one of the DOE PV-MOD research.

14 SOLAR ENERGY↗