Search NASA⌕ Search

Engineering topics

Hahn, D.

Publications and source records attributed to Hahn, D..

High-Statistics Measurement of Neutrino Quasielasticlike Scattering at 6 GeV on a Hydrocarbon Target

We measure neutrino charged-current quasielasticlike scattering on hydrocarbon at high statistics using the wideband Neutrinos at the Main Injector beam with neutrino energy peaked at 6 GeV. The double-differential cross section is reported in terms of muon longitudinal ( p ∥ ) and transverse ( p ⊥ ) momentum. Cross section contours versus lepton momentum components are approximately described by a conventional generator-based simulation, however, discrepancies are observed for transverse momenta above 0.5 GeV / c for longitudinal momentum ranges 3–5 and 9 – 20 GeV / c . The single differential cross section versus momentum transfer squared ( d σ / d Q QE 2 ) is measured over a four-decade range of Q 2 that extends to 10 GeV 2 . The cross section turnover and falloff in the Q 2 range 0.3 – 10 GeV 2 is not fully reproduced by generator predictions that rely on dipole form factors. Our measurement probes the axial-vector content of the hadronic current and complements the electromagnetic form factor data obtained using electron-nucleon elastic scattering. These results help oscillation experiments because they probe the importance of various correlations and final-state interaction effects within the nucleus, which have different effects on the visible energy in detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-pulse x-ray diffraction using polycapillary optics for in situ dynamic diffraction

Diagnostic use of single-pulse x-ray diffraction (XRD) at pulsed power facilities can be challenging due to factors such as the high flux and brightness requirements for diffraction and the geometric constraints of experimental platforms. By necessity, the x-ray source is usually positioned very close, within a few inches of the sample. On dynamic compression platforms, this puts the x-ray source in the debris field. We coupled x-ray polycapillary optics to a single-shot needle-and-washer x-ray diode source using a laser-based alignment scheme to obtain high-quality x-ray diffraction using a single 16 ns x-ray pulse with the source >1 m from the sample. Additionally, the system was tested on a Mo sample in reflection geometry using 17 keV x-rays from a Mo anode. We also identified an anode conditioning effect that increased the x-ray intensity by 180%. Quantitative measurements of the x-ray focal spot produced by the polycapillary yielded a total x-ray flux on the sample of 3.3 ± 0.5 × 10 7 molybdenum Kα photons.

47 OTHER INSTRUMENTATION↗