AIACHNE's contribution for Nuclear Energy Agency Working Party on International Nuclear Data Evaluation Co-operation Subgroup 50

The AIACHNE (AI/ML Informed cAlifornium CHi Nuclear data Experiment) project aims at designing an experiment for the 252 Cf Prompt Fission Neutron Spectrum (PFNS) that explores systematic biases in an experimental database retrieved from the EXFOR databases. To that end, machine learning (ML) methods were applied to pint-point measurement features likely related to bia. From that information, we selected a feature that should be explored by the AIACHNE experiment. Measurement features are metadata encapsulating all pertinent information about the physical measurement and analysis techniques. Examples are, for instance, what neutron and fission detectors were used for the physical metadata, and what background reduction techniques were employed for analysis techniques. Such metadata were retrieved both from EXFOR entries as well as the literature of data sets described in detail in Ref. [2]. The prerequisite for applying machine learning techniques is casting the metadata into a format that can be parsed by the algorithm. This step might seem trivial but requires to find a unique language where metadata that carry the same physics meaning across several experiments must have the same identifier. One example is, for instance, the neutron detector. As seen in Figure 1, the machine learning code identified the use of 6 Li detectors as being related to bias in some datasets of the AIACHNE 252 Cf PFNS experimental database. In fact, here are several experiments that used neutron detectors containing 6Li in the database, for instance for the example below. EXFOR format has a unique keywords describing detectors such as “SCIN” or “GLASD”. One may think that these keywords are already sufficient descriptors for ML to uniquely find an issue. However, “SCIN” (used for [3, 4]) and “GLASD” (used for [5]) fail to inform the algorithm what is the active material in the detector. And, the key common issue leading to bias in 252 Cf related to neutron detectors is not whether it is a glass detector or a scintillator. No, the issue is that 6 Li was within both detector types and that even small mistakes in the detector response functions around approximately 200 keV are amplified by the 6 Li(n,α) resonance there leading to bias in data as highlighted in Fig. 1 and Ref. [1]. Hence, the features describing the neutron detector must call out the active material in the detector, rather than the existing EXFOR detector keyword, that the ML algorithm can find physically meaningful features related to bias. The AIACHNE team used a precursor of the WPEC (Working Party on International Nuclear Data Evaluation Co-operation) SG(Subgroup)-50 format to store the metadata for the ML analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AIACHNE's contribution for Nuclear Energy Agency Working Party on International Nuclear Data Evaluation Co-operation Subgroup 50

The AIACHNE (AI/ML Informed cAlifornium CHi Nuclear data Experiment) project aims at designing an experiment for the 252 Cf Prompt Fission Neutron Spectrum (PFNS) that explores systematic biases in an experimental database retrieved from the EXFOR databases. To that end, machine learning (ML) methods were applied to pint-point measurement features likely related to bias. From that information, we selected a feature that should be explored by the AIACHNE experiment. Measurement features are metadata encapsulating all pertinent information about the physical measurement and analysis techniques. Examples are, for instance, what neutron and fission detectors were used for the physical metadata, and what background reduction techniques were employed for analysis techniques. Such metadata were retrieved both from EXFOR entries as well as the literature of data sets described in detail in Reference 2 (at the end of the article).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Prompt Fission Neutron Spectrum from 800 keV to 10 MeV for 240 Pu($sf$) and for the 240 Pu($n,f$) Reaction Induced by Neutrons of Energy from 1-20 MeV

The presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, ($n,f$), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, ($sf$), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu($sf$) and the 240 Pu($n,f$) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the ($n,f$) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third-chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SG50 Data-format Requirement Document for an Automatically Readable, Comprehensive and Curated Experimental Reaction Database MEDUSA

This report constitutes the requirement document that guides the development of the experimental reaction database, MEDUSAL (Machine-readable Experimental Data User App & Library), created by OECD/NEA/WPEC SubGroup 50. Experimental reaction data are usually stored in the EXFOR library in EXFOR format. With MEDUSAL, the WPEC sub-group 50 wants to go beyond the EXFOR format and database to generate a library that is (a) automatically readable, (b) comprehensive, and (c) curated.

Nuclear Criticality Safety Program (NCSP)↗

Templates of expected measurement uncertainties for (n, xn) cross sections

A template is provided for evaluating experimental uncertainties for neutron elastic and inelastic scattering cross sections and γ -ray production cross sections from (n, xn) measurements at laboratories with monoenergetic or white neutron sources. A typical range of uncertainties is presented for experiments detecting the scattered neutrons or the resulting de-excitation γ rays based on a survey of available data and input from many experimentalists and theorists with extensive knowledge in the field. Models commonly used to evaluate the resulting cross-sections are also discussed. Suggestions are made regarding what experimental and uncertainty information is needed for data evaluations and should be included when reporting experimental (n, xn) cross sections. Uncertainty values and correlations are recommended if these values cannot be estimated for past data from the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Project Update for “Designing Nuclear-data Measurements that Resolve Discrepancies in Existing Data” [Slides]

AIACHNE has made key progress this past year and will contribute to the larger scientific community. We recovered input data for the current 252 Cf(sf) PFNS evaluation that was previously lost. We render a standard to the best of our ability reproducible. We critically reviewed past data as input for ML & new standard evaluation that will impact PFNS of all major actinides. We developed a unique AI/ ML code that highlights which measurement features are related to bias and are working towards open-sourcing it for the community. Features that were identified as related to bias follow physics’ intuition and bring new understanding of exp effects and might help us for other reactions and isotopes. The results highlight that EXFOR is a goldmine of features that could help us understand experiment bias (if they are easy to parse).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prompt fission neutron multiplicity in the 239 Pu(n, f) reaction and its energy dependence

Measuring prompt fission neutrons to high precision is an experimental challenge, especially for radioactive fissioning nuclides. However, accurate average multiplicities, $\overline{v}_{p}$, and kinetic energy distributions of prompt fission neutrons are essential for fundamental and applied nuclear physics. We present here a recent measurement of the 239 Pu (n,f) $\overline{v}_{p}$ as a function of the incident-neutron energy, over the range 1-700 MeV. The measurement was performed with a cutting-edge setup and an innovative technique, which allowed to minimize and account for the main sources of bias. An unprecedented precision was therefore achieved. Our data are compared to GEF predictions as well as to evaluated libraries. For the first time, at low energies, the ENDF/B-VIII.0 nuclear data evaluation is validated with an independent measurement and the evaluated uncertainty reduced by up to 60%. This work paves the way to precisely measure prompt fission neutron multiplicities on highly radioactive nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the 238 U( n,f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons with 1.5–20 MeV energy

With the recent emergence of fast nuclear reactors, there has been a corresponding increasing interest in 238 U-related nuclear data. However, while existing literature data span much of the energy ranges of interest for the prompt fission neutron spectrum (PFNS) for neutron-induced fission of 238U, most literature data sets are highly correlated, and thus new, independent measurements of this quantity are needed. In this work, we report the results of a new measurement of the 238 U PFNS at the Los Alamos Neutron Science Center for incident neutron energies from 1.5–20.0 MeV, and outgoing neutron energies of 0.01–10.0 MeV. With some notable exceptions, the present results generally agree with existing literature data, especially with regard to features relating to multichance fission and pre-equilibrium features in the PFNS, thus adding confidence to existing nuclear data evaluations and filling in gaps of knowledge at previously unmeasured incident neutron energies. This result is the third in a series of PFNS measurements by the Chi-Nu collaboration now spanning all three major actinides, 239 Pu, 235 U, and 238 U. Thus, for the first time, we report reliable experimental PFNS ratios and average PFNS energy comparisons for measurements of all three of these isotopes including accurate correlations between the different, but correlated experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy dependence of prompt fissions neutron multiplicity in the 239 Pu(n, ƒ) reaction

Accurate multiplicities of prompt fission neutrons emitted in neutron-induced fission on a large energy range are essential for fundamental and applied nuclear physics. Measuring them to high precision for radioactive fissioning nuclides remains, however, an experimental challenge. In this work, the average prompt-neutron multiplicity emitted in the 239 Pu(n, ƒ) reaction was extracted as a function of the incident-neutron energy, over the range 1-700 MeV, with a novel technique, which allowed to minimize and correct for the main sources of bias and thus achieve unprecedented precision. At low energies, our data validate for the first time the ENDF/B-VIII.0 nuclear data evaluation with an independent measurement and reduce the evaluated uncertainty by up to 60%. This work opens up the possibility of precisely measuring prompt fission neutron multiplicities on highly radioactive nuclei relevant for an essential component of energy production world-wide.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Results from Recent NNSA and CEA Measurements of the 239 Pu(n, f) Prompt Fission Neutron Spectrum

The National Nuclear Security Administration (NNSA)/DP French Alternative Energies and Atomic Energy Commission (CEA)/DAM agreement on cooperation on fundamental science is a U.S.-French collaborative effort to combine intellectual and experimental resources and further the relevant nuclear science. Recently, both the NNSA and CEA experimental teams performed high-statistics measurements of the 239 Pu(n, f) prompt fission neutron spectrum (PFNS) at the Los Alamos Neutron Science Center, both of which were recently published in the journal Physical Review C. These separate measurements used the same experimental area and a common neutron detector array, but differ in many aspects, including background assessments, data acquisition systems and philosophies, fission detectors, and PFNS extraction techniques. Hence, some aspects of the experimental methods and associated uncertainties are highly correlated while others are independent. The results from both measurements broke new ground for PFNS measurements given their higher accuracy and more detailed study of corrections necessary for the measured quantity compared to existing literature measurements, and both will significantly impact PFNS nuclear data evaluations for the foreseeable future. Here, the focus of this work is to document a comparison of the results from these distinct measurements in terms of the acquired data, the PFNS results, and the measured average PFNS energies. While systematic differences between the PFNS results are present on the 1–3% level, the acquired data relative to each respective measurement at low incident neutron energies are in remarkable agreement, as are the conclusions regarding the magnitude and position of features in the PFNS relating to second-chance fission, third-chance fission, and pre-equilibrium neutron emission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of the Prompt Fission Neutron Spectrum at LANSCE: The Chi-Nu Experiment

The goal of the Chi-Nu experiment at the Los Alamos Neutron Science Center is to measure the prompt fission neutron spectra from major actinides using a double time-of-flight method with a pulsed, white incoming neutron source. Fission events are detected with a parallel-plate avalanche counter and outgoing neutrons are detected with either a 6 Li-glass or liquid scintillator detector array for low- or high-energy neutrons, respectively. A detector response matrix for the interaction of neutrons with the experimental environment for neutrons measured with the Chi-Nu 6 Li-glass detector array has been calculated to obtain a full understanding of the measured Chi-Nu data and also to allow for nearly instantaneous production of simulated Chi-Nu data spectra. Prompt fission neutron spectra corresponding to 19 incoming neutron energy ranges from 0.7-20 MeV have been extracted using the ratio-of-ratios method with Chi-Nu 6 Li-glass data on the neutron-induced fission of 235 U.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utilization of MCNP ® 6 implicit-capture simulations for quantification of systematic uncertainties from experimental environments

In this study, the high statistical precision that can be achieved using modern data collection techniques implies that systematic uncertainties that were ignored or not considered for past experiments must now be explored. The folding of Monte Carlo simulations into experimental data analysis, which is becoming common practice, requires an estimate of the systematic uncertainty present in the experimental result from uncertainties in the library of cross sections used during the simulation, but this source of uncertainty is typically not quantified. Here we describe a method to estimate this systematic uncertainty by varying the cross sections used during simulation runtime. As opposed carrying out hundreds of sequential analog Monte Carlo simulations, this task was accomplished through a post-processing calculation of output from a single simulation that was run using the implicit-capture formalism available with MCNP ® 6.2 and the PTRAC output format.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Prompt Fission Neutron Spectrum of 235 U(n,f) below 2.5 MeV for Incident Neutrons from 0.7 to 20 MeV

New prompt fission neutron spectrum measurements are reported for 235 U(n,f) reactions induced by neutrons with energies from 0.7 to 20 MeV. These measurements cover outgoing neutron energies from 2.5 MeV down to 10 keV, using an array of 6 Li-glass scintillators for neutron detection and a double time-of-flight technique. The neutrons were produced at the Weapons Neutron Research facility of the Los Alamos Neutron Science Center. A detailed MCNP ® model of the experimental equipment and the surrounding room was used to interpret the experimental results. Backgrounds were measured in situ, making use of the time-dependent singles rates of the various detectors with asynchronous readout from waveform digitizers. The results presented here have been included in a re-evaluation of the fission neutron spectra for this fissioning system, a description of which is presented elsewhere in this issue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗