Search NASA⌕ Search

Engineering topics

Halavanau, Aliaksei

Publications and source records attributed to Halavanau, Aliaksei.

Broadband hard X-ray attosecond pulses from extremely chirped electron beams

Attosecond pulses from free-electron lasers have opened the doors to atomic site-specific studies of bound electronic dynamics on their natural, sub-femtosecond timescales. Key to their success has been electron beam shaping techniques enabling the generation of sub-femtosecond current spikes with peak currents on the order of 10 kA. We demonstrate in an RF linac the generation of current spikes with extreme chirps on the order of 350 MeV/micron, directly competitive with the chirps expected from beam-driven plasma wakefield accelerators. Leveraging chirp-taper compensation, we use these highly chirped beams to generate hard X-ray attosecond pulses with bandwidths exceeding 30 eV, a factor of two beyond previous demonstrations. We simultaneously present the first explicit experimental evidence of chirp-taper compensation in an attosecond XFEL, finding that optimal tapering improves the bandwidth and pulse energy by factors of two and five, respectively, for our conditions. In addition to the immediate utility of such broadband hard X-ray pulses, electron beams with such extreme chirps can be utilized for unique new experimental modalities by performing further compression after the undulators. Such post-lasing compression can enable subsequent superradiant light emission at longer wavelengths, or direct excitation of quantum systems with the beam's intense space-charge field for unique attosecond pump-probe possibilities.

43 PARTICLE ACCELERATORS↗

X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the μ⁢m−sized electron bunches to fully overlap in three dimensions with the circulating μ⁢m−sized x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-μ⁢rad angular and μ⁢m spatial alignment of the CBXFEL cavity.

Free-electron lasers↗

Stochastic modeling of x-ray superfluorescence

An approach to modeling the dynamics of x-ray amplified spontaneous emission and superfluorescence, the phenomenon of collective x-ray emission initiated by intense pulses of x-ray free-electron lasers, is developed based on stochastic partial differential equations. The equations are derived from first principles, and the relevant approximations, derivation steps, and extensions specific to stimulated x-ray emission are presented. The resulting equations take the form of three-dimensional generalized Maxwell-Bloch equations augmented with noise terms for both field and atomic variables. The derived noise terms possess specific correlation properties that enable the correct reconstruction of spontaneous emission. Consequently, the developed theoretical formalism is universally suitable for describing all stages of stimulated x-ray emission: spontaneous emission, amplified spontaneous emission, and superfluorescence. Here, we present numerical examples that illustrate various properties of the emitted field, including spatiotemporal coherence and spectral-angular and polarization characteristics. We anticipate that the proposed theoretical framework will establish a robust foundation for interpreting measurements in stimulated x-ray emission spectroscopy, modeling x-ray laser oscillators, and describing other experiments leveraging x-ray superfluorescence.

74 ATOMIC AND MOLECULAR PHYSICS↗

Confirming X-ray Parametric Down Conversion by Time-Energy Correlation

We present measurements of X-ray Parametric Down Conversion at the Advanced Photon Source synchrotron facility. Using an incoming pump beam at 22 keV, we observe the simultaneous, elastic emission of down-converted photon pairs generated in a diamond crystal. The pairs are detected using high count rate silicon drift detectors with low noise. Production by down-conversion is confirmed by measuring time-energy correlations in the detector signal, where photon pairs within an energy window ranging from 10 to 12 keV are only observed at short time differences. By systematically varying the crystal misalignment and detector positions, we obtain results that are consistent with the constant total of the down-converted signal. Our maximum rate of observed pairs was 130 /hour, corresponding to a conversion efficiency for the down-conversion process of 5.3±0.5×10 -13 .

47 OTHER INSTRUMENTATION↗

Seeded stimulated x-ray emission at 5.9 keV: erratum

We recently identified two labeling-related mistakes in Optica 10 , 513 ( 2023 ) OPTIC8 2334-2536 10.1364/OPTICA.485989 . The first mistake concerns the labeling of the focus used during one scan. The second mistake concerns the labeling of a filter used in some runs to protect the detector. These mistakes do not affect the overall findings and conclusions in our paper, but some numbers, text, and figures are slightly affected by it. These items have been corrected and are listed below. Finally, a missing DOE award number (DE-SC0023270) has been added below.

Doyle, Margaret D.↗

Development of spinning-disk solid sample delivery system for high-repetition rate x-ray free electron laser experiments

X-ray free-electron lasers (XFELs) deliver intense x-ray pulses that destroy the sample in a single shot by a Coulomb explosion. Experiments using XFEL pulse trains or the new generation of high-repetition rate XFELs require rapid sample replacement beyond those provided by the systems now used at low repletion-rate XFELs. We describe the development and characterization of a system based on a spinning disk to continuously deliver a solid sample into an XFEL interaction point at very high speeds. We tested our system at the Linac Coherent Light Source and European XFEL hard x-ray nano-focus instruments, employing it to deliver a 25 μm copper foil sample, which can be used as a gain medium for stimulated x-ray emission for the proposed x-ray laser oscillator.

47 OTHER INSTRUMENTATION↗