Search NASA⌕ Search

Engineering topics

Halbert, Candice E

Publications and source records attributed to Halbert, Candice E.

Morphological origin for the stratification of P3HT:PCBM blend film studied by neutron reflectometry

Understanding the origin for the film stratification of electron donor/acceptor blend is crucial for high efficiency organic photovoltaic cell. In this study, P3HT:PCBM blend is deposited onto hydrophilic and hydrophobic substrate to examine the film stratifications. The neutron reflectivity results show that, on the different surfaces, PCBM diffuses toward the two interfacial regions in an identical fashion during thermal annealing. This evidences that the film stratification is not affected by the substrates. Instead, since P3HT remains more amorphous in the interfacial regions and PCBM is miscible with amorphous P3HT, PCBM preferentially diffuses to the interfacial regions, resulting in the stratification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experiment Automation with a Robot Arm using the Liquids Reflectometer Instrument at the Spallation Neutron Source

The Liquids Reflectometer instrument installed at the Spallation Neutron Source (SNS) enables observations of chemical kinetics, solid-state reactions and phase-transitions of thin film materials at both solid and liquid surfaces. Effective measurement of these behaviors requires each sample to be calibrated dynamically using the neutron beam and the data acquisition system in a feedback loop. Since the SNS is an intense neutron source, the time needed to perform the measurement can be the same as the alignment process, leading to a labor-intensive operation that is exhausting to users. An update to the instrument control system, completed in March 2013, implemented the key features of automated sample alignment and robot-driven sample management, allowing for unattended operation over extended periods, lasting as long as 20 hours. We present a case study of the effort, detailing the mechanical, electrical and software modifications that were made as well as the lessons learned during the integration, verification and testing process.

automated alignment↗

Interaction of silica nano-particles with a flat silica surface through neutron reflectometry

Neutron reflectometry (NR) was employed to study the interaction of nanosized silica particles with a flat silica surface in aqueous solutions. Unlike other experimental tools that are used to study surface interactions, NR can provide information on the particle density profile in the solution near the interface. Two types of silica particles (25 and 100 nm) were suspended in aqueous solutions of varying ionic strength. Theoretical calculations of the surface interaction potential between a particle and a flat silica surface using the Derjaguin-Landau-Verwey-Overbeek (DLVO) theory were compared to the experimental data. The theory predicts that the potential energy is highly dependent on the ionic strength. In high ionic strength solutions, NR reveals a high concentration of particles near the flat silica surface. Under the same conditions, theoretical calculations show an attractive force between a particle and a flat surface. For low ionic strength solutions, the particle concentration near the surface obtained from NR is the same as the bulk concentration, while depletion of particles near the surface is expected because of the repulsion predicted by the DLVO theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Reflectometry and QCM-D Study of the Interaction of Cellulase Enzymes with Films of Amorphous Cellulose

Improving the efficiency of enzymatic hydrolysis of cellulose is one of the key technological hurdles to reduce the cost of producing ethanol and other transportation fuels from lignocellulosic material. A better understanding of how soluble enzymes interact with insoluble cellulose will aid in the design of more efficient enzyme systems. We report a study involving neutron reflectometry (NR) and quartz crystal microbalance with dissipation (QCM-D) of the interaction of a commercial fungal enzyme extract (T. viride), two purified endoglucanses from thermophilic bacteria (Cel9A from A. acidocaldarius and Cel5A from T. maritima), and a mesophilic fungal endoglucanase (Cel45A from H. insolens) with amorphous cellulose films. The use of amorphous cellulose is motivated by the promise of ionic liquid pretreatment as a second generation technology that disrupts the native crystalline structure of cellulose. NR reveals the profile of water through the film at nm resolution, while QCM-D provides changes in mass and film stiffness. At 20 oC and 0.3 mg/ml, the T. viride cocktail rapidly digested the entire film, beginning from the surface followed by activity throughout the bulk of the film. For similar conditions, Cel9A and Cel5A were active for only a short period of time and only at the surface of the film, with Cel9A releasing 40 from the ~ 700 film and Cel5A resulting in only a slight roughening/swelling effect at the surface. Subsequent elevation of the temperature to the Topt in each case resulted in a very limited increase in activity, corresponding to the loss of an additional 60 from the film for Cel9A and 20 from the film for Cel5A, and very weak penetration into and digestion within the bulk of the film, before the activity again ceased. The results for Cel9A and Cel5A contrast sharply with results for Cel45A where very rapid and extensive penetration and digestion within the bulk of the film was observed at 20 C. We speculate that the large differences are due to the use of the thermophilic enzymes far below their optimal temperatures and also the presence of a cellulose binding module (CBM) on Cel45A while the thermophilic enzymes lack a CBM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-Resolved High Resolution Neutron Imaging Studies at the ORNL Spallation Neutron Source

Our evaluation of a high-resolution digital imaging detector capable of providing millisecond time resolution and high sensitivity for neutrons is presented. This detector is a modified version of the high-resolution -ray imager developed previously at Radiation Monitoring Devices, Inc. (RMD, Inc.), and consists of an Electron Multiplying Charge Coupled Device (EMCCD) attached to a neutron-sensitive scintillator via a fiberoptic taper. By virtue of its internal gain, the EMCCD permits high speed readout without introducing additional noise, thereby enabling high frame rate operation with an enhanced signal-to-noise ratio (SNR). Detector sensitivity is enhanced through the use of a back-thinned EMCCD, which provides high quantum efficiency over a typical emission range for many neutron-sensitive scintillators. Preliminary evaluations conducted at the Liquids Reflectometer beam port of the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) demonstrate that this new detector has the sensitivity to detect individual neutrons and the acquisition speed to perform energy-selective imaging with a temporal resolution of milliseconds. While substantial improvements in timing and imaging performance are planned, this prototype detector has already generated the first ever images of the SNS Liquids Reflectometer beam profile and was also used to demonstrate a technique for obtaining Bragg edge transmission imaging using energy-selective neutrons. The preliminary data, along with the detector design, evaluation, and planned developments are discussed in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The SNS Liquids Reflectometer

The SNS Liquids Reflectometer [1], installed as one of the first instruments at the Spallation Neutron Source, has now been functional for more than a year. This instrument is designed to view liquid and solid surfaces in specular, off specular, and near-surface small angle scattering geometries. The guide system supplies 2 {angstrom} < {angstrom} < 16.5 {angstrom} neutrons at vertical incident angles ranging from 0{sup o} < {alpha}{sub i} < 5.5{sup o} for free liquid surfaces and up to 45{sup o} for solid surfaces. Three bandwidth choppers, synchronized with the spallation source and operating at 15-60 Hz, provide neutrons in bandwidths ranging from 3.5-14 {angstrom} at a fixed incident angle onto a sample. The sample stage enables all of the motions necessary for positioning liquid and solid surfaces, while the detector arm directs a position-sensitive detector to view the sample at specular or off specular angles up to 90{sup o} and can scan out of the specular plane by up to 30{sup o}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗