Search NASA⌕ Search

Engineering topics

Hall, Chris

Publications and source records attributed to Hall, Chris.

Hypersonic Wake Velocity Measurements Using Acetone Molecular Tagging Velocimetry

A non-intrusive laser diagnostic known as molecular tagging velocimetry was used to find quantitative off-body velocity measurements in the wake of a sphere in the Mach 7 Ludwieg Tube Wind Tunnel located at The University of Texas at San Antonio. Acetone gas seeded in the flow was excited using the 4th harmonic of a pulse-burst Nd:YAG laser. The experimental results were used to validate and compare to simulations using a continuous Galerkin flow solver. Both the experimental and simulated results agreed on negative velocities in the viscous shear layer. Near the centerline of the sphere, average velocities of -200 m/s were observed due to reverse flow in the recirculation region. Outside of the shear layer, velocities of 800 m/s were observed in both the experimental and simulated results. The overall average uncertainty for the strut-mounted and free-flight case was estimated to be ±27 m/s. The flow features of the wake were visualized using schlieren imaging, and the experimental results agreed well with the simulated results.

Shoemake, Lawton↗

Field Harmonic Measurement of High-Gradient Permanent Magnet Quadrupoles for NSLS- II Upgrade

The National Synchrotron Light Source II (NSLS-II) is preparing for a major upgrade based on a new lattice concept, known as “Complex Bend,” to replace its existing double bend achromat (DBA) lattice. Here, this novel lattice will use high-gradient permanent magnet quadrupoles (PMQs) with small apertures in the range of 16–22 mm. A prototype complex bend branch with PMQs has been installed in the NSLS-II linac to evaluate the lattice's performance. An accurate and precise magnetic measurement system is required for field harmonic characterization and magnetic tuning of these PMQs. As part of this project a Rotating-Coil bench, based on a Printed Circuit Board (PCB) coil with a 12 mm diameter, has been configured to measure nine PMQs with bore diameter of 12.7 mm. This PCB coil has an active length of 270 mm, and is able to measure fields up to the 15th harmonic of the main field at a reference radius of 5 mm, while maintaining field quality levels within 10 ppm of the main field. This article presents the PCB coil setup, the harmonic measurement results and their temperature dependencies and repeatability. Simulation results on compensation of undesired multipoles using “IDBuilder”, a genetic algorithm-based optimizer code for magnetic tuning is included for field harmonic corrections.

36 MATERIALS SCIENCE↗

Performance Modeling of a Thermoelectric Heat Pump Clothes Dryer with Very High Air Flow

Previous research has shown that a clothes dryer heated by thermoelectric (Peltier) heat pumps can be up to 85% more efficient than a conventional electric-resistance dryer. A previous thermoelectric prototype used a conventional dryer’s air flow of 120 ft3/min (0.06 m3/s) and provided about 1,300 W of thermoelectric heating capacity at a heating coefficient of performance (COP) of approximately 1.2. In this work, the performance of a clothes dryer with a very high air flow rate, up to 300 ft3/min (1.14 m3/s), and only 400 W of thermoelectric heating capacity was investigated using a thermohydraulic model. Key aspects of the model were validated experimentally. Results for dry time and efficiency are presented for various air flow and heating rates.

Boudreaux, Philip↗

Estimating SHmax azimuth with P sources and vertical geophones: Use P-P reflection amplitudes or use SV-P reflection times?

We compared two methods for extracting the azimuth of maximum horizontal stress (SHmax) from 3D land-based seismic data generated by a P source and recorded with vertical geophones. In the first method, we used the direct-SV mode that is produced by all land-based P sources. P sources generate SV illumination that radiates in all azimuth directions from a source station and creates SV-P reflections that are recorded by vertical geophones. Unless stratigraphy has steep dip, SV-P raypaths recorded by vertical geophones are the reverse of P-SV raypaths recorded by horizontal geophones. Thus, SV-P data provide the same S-wave sensitivity to stress fields as popular P-SV data do. In the second method, we retrieved P-P reflections and then performed an amplitude-variation-with-azimuth (AVA) analysis of the amplitude-gradient behavior of P-P reflection wavelets. We did this analysis in narrow azimuth corridors to determine the gradient of reflection-wavelet amplitudes as a function of azimuth. This P-P AVA amplitude-gradient method has been of great interest in the reflection seismology community since it was introduced in the late 1990s. Each of these methods, AVA analysis of the gradient of P-P reflection amplitudes and azimuth-dependent arrival times of SV-P reflections, can be used to determine the azimuth of SHmax stress. We compare the results of the two methods with ground truth measurements of SHmax azimuth at a CO 2 sequestration site in the Michigan Basin. SHmax azimuths were determined from P-P and SV-P data at three major boundaries at depths of approximately 3500 ft (1067 m), 5500 ft (1676 m), and 7500 ft (2286 m). Two estimates of SHmax azimuth (one using SV-P data and one using P-P data) were made at each stacking bin inside a 24 mi 2 (62 km 2 ) image space. The result was approximately 98,000 estimates of SHmax azimuth across each of these three boundaries for each of these two prediction strategies. Histogram displays of PP AVA gradient estimates had peaks at correct azimuths of SHmax at all three depths, but the spread of the distributions widened with depth and split into two peaks at the deepest boundary. In contrast, each histogram of SHmax azimuth predicted by azimuth-dependent SV-P traveltimes had a single, definitive peak that was positioned at the correct SHmax azimuth at all three boundary depths.

Geochemistry & Geophysics↗

Determining fast-S and slow-S propagation directions with SV-P data produced by buried explosives and recorded with vertical geophones

We have evaluated the concept of practicing S-wave reflection seismology with legacy 3D seismic data generated by a P-wave source and recorded with only vertical geophones. This type of S-wave imaging is based on the principle that seismic P-wave sources not only produce a downgoing illuminating P wavefield, but they also simultaneously produce a downgoing illuminating SV wavefield that, in almost all cases, is suitable for S-wave reflection imaging. The S-mode used in this study is the SV-P, or converted-P, mode. This mode involves a downgoing illuminating SV wavefield and an upgoing reflected P-mode that is recorded by vertical geophones. In flat-layered stratigraphy, the lengths of the SV and P raypaths in SV-P imaging are identical to the lengths of the SV and P raypaths in P-SV imaging with P-sources and 3C geophones. P-SV imaging of deep rocks has been practiced for more than two decades; SV-P imaging is a new concept. SV-P data should provide the same options for investigating deep rocks as do P-SV data. We have determined one of the equivalences between SV-P data extracted from vertical-geophone data and P-SV data extracted from horizontal geophones: that both modes react to azimuth-dependent variations in the S velocity in anisotropic rocks. Azimuthal variations in the SV-P traveltime can be used to define the polarization direction of the fast-S-wave mode, which is also the azimuth of the maximum horizontal stress (SHmax). Our investigation demonstrates a noninvasive method for monitoring changes in the SHmax azimuth across a CO 2 storage reservoir, or any targeted porous rock, as fluids are cycled into, and then out of, that rock’s pore space.

Geochemistry & Geophysics↗