Search NASA⌕ Search

Engineering topics

Hall, J

Publications and source records attributed to Hall, J.

At least 19 records

Simulation of the Post-Shot Radiation Environment in the National Ignition Facility

The National Ignition Facility at Lawrence Livermore National Laboratory is the world’s biggest and most energetic laser system for inertial confinement fusion. The NIF is designed to perform shots with varying fusion yield (up to 20 MJ or 7.1 × 10 18 neutrons per shot). A great number of diagnostic instruments are present inside the target chamber (TC) and target bay (TB) during shots. The gamma dose rates due to neutron activation are estimated at various decay times following the high-yield (20-MJ) shots. Several components, like the snout assemblies of the diagnostic instrument manipulators and target positioners are inserted inside the TC, close to the target during the shot. These components represent major sources of gamma decay after retraction outside the TC. Five days after a 20-MJ shot, dose rates near the highly activated (retracted) parts are on the order of 1 mSv/h and dose rates within the TB outside the TC but at distance from the retracted components drop to about 50 to 70 μSv/h. The dose is dominated by decay of 24 Na (T 1/2 = 14.95 h) and waiting for two additional days drops the dose rates significantly. Seven days following a 20-MJ shot, dose rates in the immediate vicinity of the retracted components drop to <0.2 mSv/h and the general ambient dose rates within the TB (away from retracted components) near the TC drop to <10 μSv/h. Dose rates at much larger distances from the TC (near TB wall) are an order of magnitude lower. Detailed radiation transport simulations are performed to create detailed dose rate maps for all floors inside the TB. The maps are used to measure worker stay-out times following shots before entry is permitted into the TB.

61 RADIATION PROTECTION AND DOSIMETRY↗

Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier

These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.

47 OTHER INSTRUMENTATION↗

Ionization Measurements of SuperCDMS SNOLAB 100 mm Diameter Germanium Crystals

Scaling cryogenic Germanium-based dark matter detectors to probe smaller WIMP-nucleon cross-sections poses significant challenges in the forms of increased labor, cold hardware, warm electronics and heat load. The development of larger crystals alleviates these issues. The results of ionization tests with two 100 mm diameter, 33 mm thick cylindrical detector-grade Germanium crystals are presented here. Through these results the potential of using such crystals in the Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB experiment is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision linac and laser technologies for nuclear photonics gamma-ray sources

Tunable, high precision gamma-ray sources are under development to enable nuclear photonics, an emerging field of research. This paper focuses on the technological and theoretical challenges related to precision Compton scattering gamma-ray sources. In this scheme, incident laser photons are scattered and Doppler upshifted by a high brightness electron beam to generate tunable and highly collimated gamma-ray pulses. The electron and laser beam parameters can be optimized to achieve the spectral brightness and narrow bandwidth required by nuclear photonics applications. A description of the design of the next generation precision gamma-ray source currently under construction at Lawrence Livermore National Laboratory is presented, along with the underlying motivations. Within this context, high-gradient X-band technology, used in conjunction with fiber-based photocathode drive laser and diode pumped solid-state interaction laser technologies, will be shown to offer optimal performance for high gamma-ray spectral flux, narrow bandwidth applications.

43 PARTICLE ACCELERATORS↗

Search for inelastic dark matter with the CDMS II experiment

Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events, the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗