Search NASA⌕ Search

Engineering topics

Hall, J. A.

Publications and source records attributed to Hall, J. A..

The Data Acquisition System for Phase-III of the BeEST Experiment

The BeEST experiment is a precision laboratory search for physics beyond the standard model that measures the electron capture decay of 7 Be implanted into superconducting tunnel junction (STJ) detectors. For Phase-III of the experiment, we constructed a continuously sampling data acquisition system to extract pulse shape and timing information from 16 STJ pixels offline. Four additional pixels are read out with a fast list-mode digitizer, and one with a nuclear MCA already used in the earlier limit-setting phases of the experiment. Here, we present the performance of the data acquisition system and discuss the relative advantages of the different digitizers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Non-uniformities in Superconducting Tunnel Junction Radiation Detectors

The small dimensions of superconducting tunnel junction (STJ) radiation detectors have motivated the development of STJ arrays to increase detection efficiency and statistical accuracy. We have used a pulsed UV laser and X-rays to characterize and understand non-uniformities in the response of different pixels in Ta-based STJ arrays. To separate the contributions of the detector and the readout electronics, we have also injected the pulses from an arbitrary waveform generator into the array’s amplifier chain. We discuss the magnitude and the sources of the non-uniformity and approaches to reduce it.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Limits on the Existence of sub-MeV Sterile Neutrinos from the Decay of 7 Be in Superconducting Quantum Sensors

Sterile neutrinos are natural extensions to the standard model of particle physics and provide a possible portal to the dark sector. We report a new search for the existence of sub-MeV sterile neutrinos using the decay-momentum reconstruction technique in the decay of 7 Be. The experiment measures the total energy of the 7 Li daughter atom from the electron capture decay of 7 Be implanted into sensitive superconducting tunnel junction (STJ) quantum sensors. Here, this first experiment presents data from a single STJ operated at a low count rate for a net total of 28 days, and provides exclusion limits on sterile neutrinos in the mass range from 100 to 850 keV that improve upon previous work by up to an order of magnitude.

42 ENGINEERING↗

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗

Integrated SQUID/Sensor Metallic Magnetic Microcalorimeter for Gamma-Ray Spectroscopy

Metallic magnetic microcalorimeters (MMCs) achieve energy resolution comparable to transition-edge sensors (TESs) but rely on different measurement physics that may allow MMCs to surpass TESs in some future applications. We have recently completed fabrication of new MMC γ-ray detector arrays using several exploratory sensor designs. All designs integrate the SQUID and sensor on the same chip and use a superconducting cap layer on the paramagnet, but explore different combinations of combined/separate sensing and magnetization coils and direct/flux transformer coupling to the input SQUIDs. This report describes the design and initial testing of one of these devices, which has so far demonstrated an energy resolution of 38 eV at 60 keV near 10 mK using natural-abundance silver–erbium paramagnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Magnetic Microcalorimeters for Gamma-Ray Spectroscopy

We present that integrating the SQUIDs and sensing coils of magnetic microcalorimeters onto the same die is a promising approach for maximizing flux coupling and signal/noise. However, new challenges in microfabrication must be overcome, because the underlying SQUID devices are sensitive to chemical attack and elevated processing temperatures. In this paper, we describe development and details of a microfabrication process for integrated SQUID/sensor gamma-ray magnetic microcalorimeters with electroformed gold absorbers, starting from a modified version of the STAR Cryoelectronics “Delta 1000” Josephson Junction process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The sleep of healthy people--a diary study

To provide baseline data for various research studies at the University of Pittsburgh over a 10-year period, 266 healthy subjects (144 male, 122 female, aged 20-50 years) meeting certain criteria each completed a 14-night sleep diary. For each night, the diary allowed the subjective measurement of bedtime, wake time, time in bed (TIB), sleep efficiency, number of minutes of wake after sleep onset (WASO), alertness on awakening, and percentage of morning needing an alarm (or a person functioning as one). Weeknight versus weekend night differences in TIB (TIBdiff), weekday altertness, and reliance on alarms were examined as possible indicators of sleep debt. In addition, general descriptive data were tabulated. On average, bedtimes were at 23:48 and wake times at 07:23, yielding a mean TIB of 7 hours 35 minutes. As expected, bedtimes and wake times were later on weekend nights than on weeknights. Bedtimes were 26 minutes later, wake times 53 minutes later, yielding a mean weekend TIB increase of 27 minutes. Overall, subjects perceived their sleep latency to be 10.5 minutes, reported an average of one awakening during the night (with an average of 6.4 minutes of WASO), had a diary sleep efficiency of 96.3%, and awoke with an alterness rating of 69.5%. These variables differed little between weeknight and weekend nights. Subjects used an alarm (or a person functioning as an alarm) on 60.9% nights overall, 68.3% on weeknights, 42.5% on weekends. When TIBdiff was used as an estimate of sleep debt (comparing subjects with TIBdiff > 75 minutes with those with a TIBdiff < 30 minutes), the group with more "catch-up sleep" on weekends had shorter weeknight TIB durations (by about 24 minutes) and relied more on an alarm for weekday waking (by about 22%), indicating the possible utility of these variables as sleep debt indices.

NASA Program Biomedical Research and Countermeasur↗

Multispectral linear array focal plane

A description is provided of a sensor chip array for a unified multispectral focal plane for the Multispectral Linear Array (MLA) instrument. The involved concept of sensing multispectral earth resources imagery through the use of spectral filters deposited directly on a single row of silicon charge-coupled device (CCD) chips has been considered for a number of years. A simplified focal plane was designed after a number of experiments. Technology considerations regarding the design of the multispectral focal plane are discussed. Experimental data are presented which show that the arising problems have been or can be solved.

Hall, J. A.↗

Electronography

Large roll-film electronographic camera for aerial reconnaissance and astronomical observations

Hall, J. A.↗