Search NASA⌕ Search

Engineering topics

Hallinan, Kevin P.

Publications and source records attributed to Hallinan, Kevin P..

Capillary Pumped Heat Transfer (CHT) Experiment

The operation of Capillary Pumped Loops (CPL's) in low gravity has generally been unable to match ground-based performance. The reason for this poorer performance has been elusive. In order to investigate the behavior of a CPL in low-gravity, an idealized, glass CPL experiment was constructed. This experiment, known as the Capillary-driven Heat Transfer (CHT) experiment, was flown on board the Space Shuttle Columbia in July 1997 during the Microgravity Science Laboratory mission. During the conduct of the CHT experiment an unexpected failure mode was observed. This failure mode was a result of liquid collecting and then eventually bridging the vapor return line. With the vapor return line blocked, the condensate was unable to return to the evaporator and dry-out subsequently followed. The mechanism for this collection and bridging has been associated with long wavelength instabilities of the liquid film forming in the vapor return line. Analysis has shown that vapor line blockage in present generation CPL devices is inevitable. Additionally, previous low-gravity CPL tests have reported the presence of relatively low frequency pressure oscillations during erratic system performance. Analysis reveals that these pressure oscillations are in part a result of long wavelength instabilities present in the evaporator pores, which likewise lead to liquid bridging and vapor entrapment in the porous media. Subsequent evaporation to the trapped vapor increases the vapor pressure. Eventually the vapor pressure causes ejection of the bridged liquid. Recoil stresses depress the meniscus, the vapor pressure rapidly increases, and the heated surface cools. The process then repeats with regularity.

Hallinan, Kevin P.↗

Effects of thermocapillarity on an evaporating extended meniscus in microgravity

An analytical investigation of the effects of thermocapillarity on the flow field within and heat transfer from the extended meniscus region of a heated meniscus which is re-supplied by capillarity is presented. Microgravity conditions are considered. The analysis shows that even for extremely small temperature differences between the wall and the vapor (less than 1 mK) thermocapillary stresses at the liquid-vapor interface due to a non-uniform interfacial temperature drastically alters the flow field. At the same time, these stresses were shown to have only a slight effect on the heat transfer from the extended meniscus but increasing with an increasing temperature difference. Additionally, thermocapillary effects were shown to be sensitive to pore size. A criterion was established from a scaling analysis identifying the conditions necessary for thermocapillarity to affect the operation of capillary-pumped heat transport devices in microgravity. A critical Marangoni number and corresponding critical temperature difference between wall and vapor were identified.

Hallinan, Kevin P.↗