Alternating current magnetic susceptibility and heat dissipation by Mn{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} nanoparticles for hyperthermia treatment

Mn-Zn ferrite, Mn{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} nanoparticles encapsulated in amorphous SiO{sub 2} were prepared using our original wet chemical method. X-ray diffraction patterns confirmed that the diameters of these particles were within 7–30 nm. Magnetization measurements for various sample compositions revealed that the saturation magnetization (M{sub s}) of 7 nm particles was maximum for the x = 0.2 sample. AC magnetic susceptibility measurements were performed for Mn{sub 0.8}Zn{sub 0.2}Fe{sub 2}O{sub 4} (x = 0.2) samples with 13–30 nm particles. The peak of the imaginary part of the magnetic susceptibility χ″ shifted to higher temperatures as the particle size increased. An AC field was found to cause the increase in temperature, with the 18 nm particles exhibiting the highest temperature increase, as expected. In addition, in vitro experiments were carried out to study the hyperthermia effects of Mn{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} (x = 0.2, 18 nm) particles on human cancer cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative testing of various flow-cell detectors fabricated using CaF{sub 2} solid scintillator

A monitoring system based on a flow-cell detector was developed for measuring the tritium concentration in water. The flow-cell detector was fabricated using a granular CaF{sub 2} solid scintillator. This system does not use a liquid scintillation counting system and does not generate radioactive organic liquid waste. Moreover, continuous real-time measurements are possible, in contrast to a liquid scintillation counting system, which requires batch measurements. For further development of the system, four flow-cell detectors were fabricated. They included a single 3-mm-diameter cell, three 3-mm-diameter cells in series, a single 5-mm-diameter cell, and three 5-mm-diameter cells in series. Continuously flowing water containing tritium at various concentrations was passed through the flow cells, and tritium count were measured for 600 and 10000 s. Investigating the relation between the count rate and concentration, the three 5-mm-diameter cells were most sensitive, with a linear relation maintained down to approximately 2 Bq/ml and 10 Bq/ml for 10000- and 600-s measurements, respectively. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D potential measurements by applying automatic beam adjustment system to heavy ion beam probe diagnostic on the Large Helical Device

Two-dimensional potential profiles in the Large Helical Device (LHD) were measured with heavy ion beam probe (HIBP). To measure the two-dimensional profile, the probe beam energy has to be changed. However, this task is not easy, because the beam transport line of LHD-HIBP system is very long (∼20 m), and the required beam adjustment consumes much time. To reduce the probe beam energy adjustment time, an automatic beam adjustment system has been developed. Using this system, required time to change the probe beam energy is dramatically reduced, such that two-dimensional potential profiles were able to be successfully measured with HIBP by changing the probe beam energy shot to shot.

43 PARTICLE ACCELERATORS↗