Search NASA⌕ Search

Engineering topics

Hamilton, D. R.

Publications and source records attributed to Hamilton, D. R..

Orbital and Intracranial Effects of Microgravity: 3T MRI Findings

Goals and Objectives of this presentation are: 1. To briefly describe a newly discovered clinical entity related to space flight. 2. To describe normal anatomy and pathologic changes of the optic nerve, posterior globe, optic nerve sheath and pituitary gland related to exposure to microgravity. 3. To correlate imaging findings with known signs of intracranial hypertension.

Kramer, L. A.↗

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using "Braslet-M" Occlusion Cuffs

BACKGROUND: The transition to microgravity eliminates the hydrostatic gradients in the vascular system. The resulting fluid redistribution commonly manifests as facial edema, engorgement of the external neck veins, nasal congestion, and headache. This experiment examined the responses to modified Valsalva and Mueller maneuvers as measured by cardiac and vascular ultrasound in a baseline microgravity steady state, and under the influence of thigh occlusion cuffs (Braslet cuffs). METHODS: Nine International Space Station crewmember subjects (Expeditions 16 - 20) were examined in 15 experiment sessions 101 46 days after launch (mean SD; 33 - 185). 27 cardiac and vascular parameters were obtained under three respiratory conditions (baseline, Valsalva, and Mueller) before and after tightening of the Braslet cuffs for a total of 162 data points per session. The quality of cardiac and vascular ultrasound examinations was assured through remote monitoring and guidance by Investigators from the NASA Telescience Center in Houston, TX, USA. RESULTS: Fourteen of the 81 measured conditions were significantly different with Braslet application and were apparently related to cardiac preload reduction or increase in the venous volume sequestered in the lower extremity. These changes represented 10 of the 27 parameters measured. In secondary analysis, 7 of the 27 parameters were found to respond differently to respiratory maneuvers depending on the presence or absence of thigh compression, with a total of 11 differences. CONCLUSIONS: Acute application of Braslet occlusion cuffs causes lower extremity fluid sequestration and exerts proportionate measurable effects on cardiac performance in microgravity. Ultrasound techniques measuring the hemodynamic effects of thigh cuffs in combination with respiratory maneuvers may serve as an effective tool in determining the volume status of a cardiac or hemodynamically compromised patient in microgravity.

Hamilton, D. R.↗

Quantification of Posterior Globe Flattening: Methodology Development and Validationc

Microgravity exposure affects visual acuity in a subset of astronauts, and mechanisms may include structural changes in the posterior globe and orbit. Particularly, posterior globe flattening has been implicated in several astronauts. This phenomenon is known to affect some terrestrial patient populations, and has been shown to be associated with intracranial hypertension. It is commonly assessed by magnetic resonance imaging (MRI), computed tomography (CT), or B-mode ultrasound (US), without consistent objective criteria. NASA uses a semi-quantitative scale of 0-3 as part of eye/orbit MRI and US analysis for occupational monitoring purposes. The goal of this study was to initiate development of an objective quantification methodology for posterior globe flattening.

Lumpkins, S. B.↗

Acute Modifications of Circulating Volume and Respiratory Maneuvers in the Cardiovascular Assessment of Long-Duration Crewmembers

This U.S. - Russian project is aimed at improved assessment of cardiac and vascular parameters associated with circulating volume and its distribution in long-duration space flight. Objective responses to modified Valsalva and Mueller maneuvers were measured by cardiac and vascular ultrasound before, during, and after temporary volume redistribution by means of Braslet-M thigh occlusion cuffs (Russia). Braslet-M cuffs are custom fitted to each crewmember prior to launch on the Soyuz as a Russian countermeasure for space adaptation fluid shifts

Bogomolov, V. V.↗

Atrial Arrhythmias and Their Implications for Space Flight - Introduction

This panel will discuss the implications of atrial arrhythmias in astronauts from a variety of perspectives; including historical data, current practices, and future challenges for exploration class missions. The panelists will present case histories, outline the evolution of current NASA medical standards for atrial arrhythmias, discuss the use of predictive tools, and consider potential challenges for current and future missions.

Polk, J. D.↗

Right Ventricular Tissue Doppler Assessment in Space During Circulating Volume Modification using the Braslet-M Device

This joint U.S. - Russian work aims to establish a methodology for assessing cardiac function in microgravity in association with manipulation of central circulating volume. Russian Braslet-M occlusion cuffs were used to temporarily increase the volume of blood in the lower extremities, which effectively reduces the volume returning to the heart in the central circulation. A novel methodology was tested on the International Space Station (ISS) to assess the volume status of crewmembers by evaluating the responses to application and release of the Braslet-on-occlusion cuffs, as well as to modified Valsalva and Mueller maneuvers. Baseline echocardiographic tissue Doppler imaging (TDI) of the right ventricular free wall with no Braslet applied shows early diastolic E' (16 cm/sec), late diastolic A' (14 cm/sec), and systolic (12 cm/sec) velocities compatible with normal subjects on Earth. TDI of the RV free wall with Braslet applied shows that early diastolic E' decreased by 50% (8 cm/sec), late diastolic A' increased by 45%, and systolic S' remains unchanged. TDI of the RV free wall approximately 8 beats after the Braslet was released shows early diastolic E' (8 cm/sec), late diastolic A' (12 cm/sec), and systolic S' (13 cm/sec) velocities. During this portion of the release, early diastolic E' did not recover to baseline values but late diastolic A' and systolic S' recovered to pre-Braslet values. The pre-systolic cross-sectional area of the internal jugular vein with Braslet off was 1.07 cm(sup 2) and 1.13 cm(sup 2) 10 min after the Braslet was applied. The presystolic cross-sectional area of the common femoral vein with Braslet off was 0.50 cm(sup 2), and was 0.54 cm(sup 2) 10 min after the Braslet was applied. The right ventricular myocardial performance Tei index also was calculated for comparison with typical values found in healthy subjects on Earth. Baseline and Braslet-on values for Tei index were 0.25 and 0.22 respectively. Braslet Tei indices are within normal ranges found in healthy subjects and temporarily become greater than 0.4 during the dynamic Braslet release portion of this study. Tissue Doppler imaging of the right ventricle revealed that the Braslet influenced cardiac preload and that fluid was sequestered in the lower-extremity interstitial and vascular space after only 10 minutes of application. This report demonstrates that Braslet application affects right ventricular physiology in long-duration space flight based on TDI and that this effect is in part due to venous hemodynamics.

Hamilton, D. R.↗

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using Ultrasound and "Braslet-M" Occlusion Cuffs

Recent advances in remotely guided imaging techniques on ISS allow the acquisition of high quality ultrasound data using crewmember operators with no medical background and minimal training. However, ongoing efforts are required to develop and validate methodology for complex imaging protocols to ensure their repeatability, efficiency, and suitability for use aboard the ISS. This Station Developmental Test Objective (SDTO) tests a cardiovascular evaluation methodology that takes advantage of the ISS Ultrasound capability, the Braslet-M device, and modified respiratory maneuvers (Valsalva and Mueller), to broaden the spectrum of anatomical and functional information on human cardiovascular system during long-duration space missions. The proposed methodology optimizes and combines new and previously demonstrated methods, and is expected to benefit medically indicated assessments, operational research protocols, and data collections for science. Braslet-M is a current Russian operational countermeasure that compresses the upper thigh to impede the venous return from lower extremities. The goal of the SDTO is to establish and validate a repeatable ultrasound-based methodology for the assessment of a number of cardiovascular criteria in microgravity. Braslet-M device is used as a means to acutely alter volume distribution while focused ultrasound measurements are performed. Modified respiratory maneuvers are done upon volume manipulations to record commensurate changes in anatomical and functional parameters. The overall cardiovascular effects of the Braslet-M device are not completely understood, and although not a primary objective of this SDTO, this effort will provide pilot data regarding the suitability of Braslet-M for its intended purpose, effects, and the indications for its use.

Bogomolov, V. V.↗

Percutaneous aspiration of fluid for management of peritonitis in space

BACKGROUND: As a medical emergency that can affect even well-screened, healthy individuals, peritonitis developing during a long-duration space exploration mission may dictate deviation from traditional clinical practice due to the absence of otherwise indicated surgical capabilities. Medical management can treat many intra-abdominal processes, but treatment failures are inevitable. In these circumstances, percutaneous aspiration under sonographic guidance could provide a "rescue" strategy. Hypothesis: Sonographically guided percutaneous aspiration of intra-peritoneal fluid can be performed in microgravity. METHODS: Investigations were conducted in the microgravity environment of NASA's KC-135 research aircraft (0 G). The subjects were anesthetized female Yorkshire pigs weighing 50 kg. The procedures were rehearsed in a terrestrial animal lab (1 G). Colored saline (500 mL) was introduced through an intra-peritoneal catheter during flight. A high-definition ultrasound system (HDI-5000, ATL, Bothell, WA) was used to guide a 16-gauge needle into the peritoneal cavity to aspirate fluid. RESULTS: Intra-peritoneal fluid collections were easily identified, distinct from surrounding viscera, and on occasion became more obvious during weightless conditions. Subjectively, with adequate restraint of the subject and operators, the procedure was no more demanding than during the 1-G rehearsals. CONCLUSIONS: Sonographically guided percutaneous aspiration of intra-peritoneal fluid collections is feasible in weightlessness. Treatment of intra-abdominal inflammatory conditions in spaceflight might rely on pharmacological options, backed by sonographically guided percutaneous aspiration for the "rescue" of treatment failures. While this risk mitigation strategy cannot guarantee success, it may be the most practical option given severe resource limitations.

Non-NASA Center↗

Advanced Ultrasonic Diagnosis of Extremity Trauma: The Faster Exam

Ultrasound is of prO)len accuracy in abdominal and thoracic trauma and may be useful to diagnose extremity injury in situations where radiography is not available such as military and space applications. We prospectively evaluated the utility of extremity , ultrasound performed by trained, non-physician personnel in patients with extremity trauma, to simulate remote aerospace or military applications . Methods: Patients with extremity trauma were identified by history, physical examination, and radiographic studies. Ultrasound examination was performed bilaterally by nonphysician personnel with a portable ultrasound device using a 10-5 MHz linear probe, Images were video-recorded for later analysis against radiography by Fisher's exact test. The average time of examination was 4 minutes. Ultrasound accurately diagnosed extremity, injury in 94% of patients with no false positive exams; accuracy was greater in mid-shaft locations and least in the metacarpa/metatarsals. Soft tissue/tendon injury was readily visualized . Extremity ultrasound can be performed quickly and accurately by nonphysician personnel with excellent accuracy. Blinded verification of the utility of ultrasound in patients with extremity injury should be done to determine if Extremity and Respiratory evaluation should be added to the FAST examination (the FASTER exam) and verify the technique in remote locations such as military and aerospace applications.

Dulchavsky, S. A.↗

Prospective Evaluation of Thoracic Ultrasound in the Detection of Pneumothorax

Introduction: Pneumothorax (PTX) occurs commonly in trauma patients and is confirmed by examination and radiography. Thoracic ultrasound (VIS) has been suggested as an alternative method for rapidly diagnosing PTX when X-ray is unavailable as in rural, military, or space flight settings; however, its accuracy and specificity are not known. Methods: We evaluated the accuracy of thoracic U/S detection of PTX compared to radiography in stable, emergency patients with a high suspicion of PTX at a Level-l trauma center over a 6-month period. Following University and NASA Institutional Review Board approval, informed consent was obtained from patients with penetrating or blunt chest trauma, or with a history consistent with PTX. Whenever possible, the presence or absence of the " lung sliding" sign or the "comet tail" artifact were determined by U/S in both hemithoraces by residents instructed in thoracic U/S before standard radiologic verification of PTX. Results were recorded on data sheets for comparison to standard radiography. Results: Thoracic VIS had a 94% sensitivity; two PTX could not be reliably diagnosed due to subcutaneous air; the true negative rate was 100%. In one patient, the VIS exam was positive while X ray did not confirm PTX; a follow-up film 1 hour later demonstrated a small PTX. The average time for bilateral thoracic VIS examination was 2 to 3 minutes. Conclusions: Thoracic ultrasound reliably diagnoses pneumothorax. Presence of the "lung sliding" sign conclusively excludes pneumothorax. Expansion of the FAST examination to include the thorax should be investigated.

Schwarz, K. W.↗

Ultrasound Evaluation of the Magnitude of Pneumothorax: A New Concept

Pneumothorax is commonly seen in trauma patients; the diagnosis is usually confirmed by radiography. Use of ultrasound for this purpose, in environments such as space flight and remote terrestrial areas where radiographic capabilities are absent, is being investigated by NASA. In this study, the ability of ultrasound to assess the magnitude of pneumothorax in a porcine model was evaluated. Sonography was performed on anesthetized pigs (avg. wt. 50 kg) in both ground-based laboratory (n = 5) and micro gravity conditions (0 g) aboard the KC-135 aircraft during parabolic flight (n = 4). Aliquots of air (50-1 OOcc) were introduced into the chest through a catheter to simulate pneumothorax. Results were video-recorded and digitized for later interpretation by radiologists. Several distinct sonographic patterns of partial lung sliding were noted, including the combination of a sliding zone with a still zone, and a "segmented" sliding zone. These "partial lung sliding" patterns exclude massive pneumothorax manifested by a complete separation of the lung from the parietal pleura. In 0 g, the sonographic picture was more diverse; 1 g differences between posterior and anterior aspects were diminished. CONCLUSIONS: Modest pneumothorax can be inferred by the ultrasound sign of "partial lung sliding". This finding, which increases the negative predictive value of thoracic ultrasound, may be attributed to intermittent pleural contact, small air spaces, or alterations in pleural lubricant. Further studies of these phenomena are warranted.

Sargsyan, Ashot E.↗

Offgassing of non-metallic materials in 5 psia oxygen

Analysis of a wide variety on nonmetallic materials for offgassing products, including carbon monoxide and total hydrocarbons in 5 psia oxygen are reported. A general method as described in MSFC-SPEC-101B Offgassing Support Combustion.

Wells, F. T.↗

Development of high speed power thyristor: The gate assisted turn-off thyristor

A high speed power switch with unique turn-off capability was developed. This gate-assisted turn-off thyristor was rated at 609 V and 50 A with turn-off times of 2 microsec. Twenty-two units were delivered for evaluation in a series inverter circuit. In addition, test circuits designed to relate to the series inverter application were built and demonstrated.

Hamilton, D. R.↗