Dispatch optimization of electric thermal energy storage within System Advisor Model

A stand-alone electric thermal energy storage (ETES) system converts low-value electricity into heat using resistance heating elements. During periods of high-value electricity, an ETES system uses a thermodynamic power cycle to convert stored thermal energy back to electricity. These dispatchable systems derive value from their ability to store energy when prices are low and generate electricity when prices are favorable, i.e., energy arbitrage. Consequently, dispatch optimization of system operations, through maximizing revenue subject to system constraints, is essential to evaluate the economic value of a particular system design. While stand-alone ETES systems offer potential advantages as dispatchable grid storage technologies, there is a lack of a neutral third-party, publicly available, open-source model to evaluate the performance, dispatch, and financial viability of these systems. To address this problem, we have developed a techno-economic model for stand-alone ETES systems, within National Renewable Energy Laboratory's (NREL's) System Advisor Model (SAM). We implement a mixed-integer linear program to determine an ETES optimal operating schedule that maximizes electricity sales less maintenance costs caused by operation and cycling given temporal-varying grid electricity prices. Our contributions include a mixed-integer linear program for energy arbitrage of an ETES system, an ETES performance model through a publicly-available software (i.e., SAM), and an exercise of our model through case studies that compare ETES operational strategies and annual financial metrics. With our dispatch optimization model, we were able to improve revenue by 20% compared to a myopic heuristic while reducing the operational cost of the ETES system through decreases in cycle starts, cycles per day, and heater starts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parametric analysis on optimized design of hybrid solar power plants

There is increasing interest in utility-scale solar power plants with storage which can flexibly dispatch renewable energy to the grid. However, plant design possesses many degrees of freedom and non-obvious trade-offs in performance. Software tools can estimate or optimize the performance of a specific plant configuration under market and weather conditions of interest; the associated cost parameters and operating assumptions strongly influence estimates of plant performance and decisions regarding optimal sizing. We employ the National Renewable Energy Laboratory's Hybrid Optimization and Performance Platform, which incorporates optimal dispatch when evaluating plant performance, and investigate the sensitivity to weather and market conditions, operating limitations, and the presence of a capacity-based incentive. We demonstrate changes in plant performance and optimal sizing with respect to these inputs and discuss implications. Here results show that PV-with-battery designs are more profitable under our assumptions, but that designs including a concentrated solar power (CSP) system produce significantly greater annual energy; and that CSP-with-thermal energy storage designs maximizing the benefit-to-cost ratio have an input-dependent linear relationship between the CSP field solar multiple and the hours of storage as the project budget varies.

14 SOLAR ENERGY↗

Real-time dispatch optimization for concentrating solar power with thermal energy storage

Concentrating solar power (CSP) plants present a promising path towards utility-scale renewable energy. The power tower, or central receiver, configuration can achieve higher operating temperatures than other forms of CSP, and, like all forms of CSP, naturally pairs with comparatively inexpensive thermal energy storage, which allows CSP plants to dispatch electricity according to market price incentives and outside the hours of solar resource availability. Currently, CSP plants commonly include a steam Rankine power cycle and several heat exchange components to generate high-pressure steam using stored thermal energy. The efficiency of the steam Rankine cycle depends on the temperature of the plant's operating fluid, and so is a main concern of plant operators. However, the variable nature of the solar resource and the conservatism with which the receiver is operated prevent perfect control over the receiver outlet temperature. Therefore, during periods of solar variability, collection occurs at lower-than-design temperature. To support operator decisions in a real-time setting, we develop a revenue-maximizing non-convex mixed-integer, quadradically-constrained program which determines a dispatch schedule with sub-hourly time fidelity and considers temperature-dependent power cycle efficiency. The exact nonlinear formulation proves intractable for real-time decision support. Here we present exact and inexact techniques to improve problem tractability that include a hybrid nonlinear and linear formulation. Our approach admits solutions within approximately 3% of optimality, on average, within a five-minute time limit, demonstrating its usability for decision support in a real-time setting.

14 SOLAR ENERGY↗

Demonstrating solarpilot ’s Python Application Programmable Interface Through Heliostat Optimal Aimpoint Strategy Use Case

solarpilot is a software package that generates solar field layouts and characterizes the optical performance of concentrating solar power (CSP) tower systems. solarpilot was developed by the National Renewable Energy Laboratory (NREL) as a stand-alone desktop application but has also been incorporated into NREL’s System Advisor Model (SAM) in a simplified format. Prior means for user interaction with solarpilot have included the application’s graphical interface, the SAM routines with limited configurability, and through a built-in scripting language called “LK.” This article presents a new, full-featured, python-based application programmable interface (API) for solarpilot, which we hereafter refer to as CoPylot. CoPylot enables python users to perform detailed CSP tower analysis utilizing either the Hermite expansion technique (analytical) or the SolTrace ray-tracing engine. CoPylot’s enables CSP researchers to perform analysis that was previously not possible through solarpilot’s existing interfaces. This article discusses the capabilities of CoPylot and presents a use case wherein we populate a model that obtains optimal solar field aiming strategies.

14 SOLAR ENERGY↗

Black-Box Optimization for Design of Concentrating Solar Power and Photovoltaic Hybrid Systems with Optimal Dispatch Decisions

The hybridization of concentrating solar power (CSP) and photovoltaics (PV) can enable dispatchable renewable electricity generation at a lower price than current stand-alone CSP systems. However, designing a CSP-PV hybrid system can be challenging because of the many degrees of freedom in design that affect the internal and external system interactions and trade-offs. We develop a methodology to determine optimal designs for CSP-PV hybrids by implementing NLopt's derivative-free, or “black-box,” algorithms around pre-existing CSP-PV hybrid simulation software that utilizes the National Renewable Energy Laboratory’s System Advisor Model (SAM); we then employ a dispatch optimization model to determine operational decisions that maximize a plant’s profits. We present optimal designs for CSP-PV hybrid systems dispatching against four time-of-delivery (ToD) pricing structures. NLopt’s algorithms can improve the base case design’s power purchase agreement (PPA) price by 15% to 21%, depending on the ToD pricing structure. In addition, we present the resulting optimal CSP-PV hybrid design’s annual performance metrics, which tend to have capacity factors between 50% and 62%, but are able to generate electricity during the year’s highest-valued periods about 90% of the time. Lastly, we investigate the trade-offs between capacity factor and PPA price using Pareto fronts and demonstrate that, for some ToD pricing structures, the system capacity factor can increase by 20% but at the expense of a 2% increase in PPA price.

black-box↗

Off-design performance of molten salt-driven Rankine cycles and its impact on the optimal dispatch of concentrating solar power systems

This paper presents a model for improving off-design performance predictions for molten salt-driven Rankine power cycles, such as in concentrating solar power tower applications. The model predicts cycle off-design performance under various boundary conditions, including molten salt inlet temperature, mass flow rate, and ambient temperature. The model is validated using industry performance data and benchmarked with results from the literature. A complete concentrating solar power plant, inclusive of solar heliostat field and receiver, is then considered, by implementing the Rankine cycle off-design performance results into the National Renewable Energy Laboratory’s System Advisor Model software, which includes a tool that determines optimal power production schedules. The work improves upon the current System Advisor Model by updating off-design performance characteristics. A case study demonstrates the impact of cycle off-design behavior on annual performance for a stand-alone concentrating solar power system and a concentrating solar power-photovoltaic hybrid system. In addition, we demonstrate how cycle off-design performance influences optimal operator dispatch decisions and, thereby, overall system design and economics. We conclude that off-design cycle performance impacts “optimal” sub-system sizing, especially for a concentrating solar power-photovoltaic hybrid configuration in which concentrating solar power must dispatch in conjunction with photovoltaic generation.

14 SOLAR ENERGY↗

Dispatch optimization of concentrating solar power with utility-scale photovoltaics

Concentrating solar power (CSP) tower technologies capture thermal radiation from the sun utilizing a field of solar-tracking heliostats. When paired with inexpensive thermal energy storage (TES), CSP technologies can dispatch electricity during peak-market-priced hours, day or night. The cost of utility-scale photovoltaic (PV) systems has dropped significantly in the last decade, resulting in inexpensive energy production during daylight hours. The hybridization of PV and CSP with TES systems has the potential to provide continuous and stable energy production at a lower cost than a PV or CSP system alone. Hybrid systems are gaining popularity in international markets as a means to increase renewable energy portfolios across the world. Typically, CSP-PV hybrid systems have been evaluated using either monthly averages of hourly PV production or scheduling algorithms that neglect the time-of-production value of electricity in the market. To more accurately evaluate a CSP-PV-battery hybrid design, we develop a profit-maximizing mixed-integer linear program ($\mathcal{H}$) that determines a dispatch schedule for the individual sub-systems with a sub-hourly time fidelity. We introduce the mathematical formulation of such a model and show that it is computationally expensive to solve. To improve model tractability and reduce solution times, we offer techniques that: (1) reduce the problem size, (2) tighten the linear programming relaxation of ($\mathcal{H}$) via reformulation and the introduction of cuts, and (3) implement an optimization-based heuristic (that can yield initial feasible solutions for (($\mathcal{H}$) and, at any rate, yields near-optimal solutions). Applying these solution techniques results in a 79% improvement in solve time, on average, for our 48-h instances of (($\mathcal{H}$); corresponding solution times for an annual model run decrease by as much as 93%, where such a run consists of solving 365 instances of (($\mathcal{H}$), retaining only the first 24 h' worth of the solution, and sliding the time window forward 24 h. We present annual system metrics for two locations and two markets that inform design practices for hybrid systems and lay the groundwork for a more exhaustive policy analysis. A comparison of alternative hybrid systems to the CSP-only system reflects that hybrid models can almost double capacity factors while resulting in a 30% improvement related to various economic metrics.

14 SOLAR ENERGY↗

Optimizing dispatch for a concentrated solar power tower

Concentrating solar power (CSP) systems employ a sophisticated thermal receiver, power cycle, and a heliostat field, comprised of thousands of mirrors spread over hundreds of acres of land, and are most cost-effective with relatively large quantities of energy storage which can be scheduled for dispatch. We exercise an existing optimization model that maximizes revenue over a year-long time horizon, solved using a standard 48-h look-ahead policy at hourly fidelity on a CSP system under development in California. The system employs molten salt power tower technology with a 150 MWe (net) turbine, eight hours of thermal storage at full load, and a solar field that provides 1.75 times the rated turbine thermal power. The model considers system configuration and interoperability aspects, such as storage tank size, production capacities, and ramp rates, and determines decisions that expedite financing, permitting, and plant design. Relative to results achieved via industry practice, the existing optimization model reduces the number of power cycle (i.e., turbine) start-up events by 86.4%, thereby improving net revenue by more than 8.5% annually; this corresponds to an approximately $140 M increase in net revenue over the lifetime of the plant, taking a step towards advancing the long-term economic viability of large-scale renewable energy systems. Sensitivity analysis on uncertain parameter values provides insight regarding those values that influence profit most significantly.

14 SOLAR ENERGY↗

Wind-Tunnel Tests of a 0.16-Scale Model of the Douglas MX-656 Airplane at High Subsonic Speeds: Stability and Control Characteristics - 1

Wind tunnel tests of the 0.16-scale Douglas MX-656 model were made at low and high subsonic Mach numbers to investigate the static longitudinal- and lateral stability characteristics. The tests shows that undesirable changes in longitudinal stability at the stall were apparently caused by an altered downwash pattern at the tail. The jettisonable nose fins were highly destabilizing. Compressibility effects for the test Mach numbers were not detrimental to the longitudinal- or lateral-stability characteristics.

Hamilton, William T.↗