Search NASA⌕ Search

Engineering topics

Han, Bong-Gyoon

Publications and source records attributed to Han, Bong-Gyoon.

Methods of supporting a graphene sheet disposed on a frame support

This disclosure provides systems, methods, and apparatus related to graphene. In one aspect, a method includes submerging a frame support in an etching solution that is contained in a container. A growth substrate, a graphene sheet disposed on the growth substrate, and a primary support disposed on the graphene sheet is placed on a surface of the etching solution. The growth substrate is dissolved in the etching solution to leave the graphene sheet and the primary support floating on a surface of the etching solution. The etching solution in the container is replaced with a washing solution. The washing solution is removed from the container so that the graphene sheet becomes disposed on the frame support.

Han, Bong-Gyoon↗

Streptavidin Affinity Grids for the Preparation of Biological Samples for Cryogenic Electron Microscopy (CRADA Final Report)

Currently, cryo-EM is the most powerful tool for structural analysis of large biomacromolecules, but there are still problems in that biomacromolecules are denatured at the air-interface and their orientations are limited in a specific orientation. We solved this problem at LBL by developing a streptavidin-coated EM grid. Use of such affinity-binding grids can minimize exposure to air-interface by keeping biomacromolecules bound to streptavidin. It is urgently needed to make such grids readily available to the cryo-EM community, but they are somewhat difficult to make. The goal of the CRADA with Hummingbird company was to mass-produce the streptavidin grids so that they would become readily available to the cryo-EM community. Our contribution to the CRADA was to first help Hummingbird to replicate the manual process that we use, and this was completed successfully.

59 BASIC BIOLOGICAL SCIENCES↗

Perspective: Biochemical and Physical Constraints Associated With Preparing Thin Specimens for Single-Particle Cryo-EM

While many aspects of single-particle electron cryo-microscopy (cryo-EM) of biological macromolecules have reached a sophisticated level of development, this is not yet the case when it comes to preparing thin samples on specimen grids. As a result, there currently is considerable interest in achieving better control of both the sample thickness and the amount of area that is useful, but this is only one aspect in which improvement is needed. This Perspective addresses the further need to prevent the macromolecular particles from making contact with the air-water interface, something that can result in preferential orientation and even structural disruption of macromolecular particles. This unwanted contact can occur either as the result of free diffusion of particles during the interval between application, thinning and vitrification of the remaining buffer, or—when particles have been immobilized—by the film of buffer becoming too thin prior to vitrification. An opportunity now exists to apply theoretical and practical insights from the fields of thin-film physical chemistry and interfacial science, in an effort to bring cryo-EM sample preparation to a level of sophistication that is comparable to that of current data collection and analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Stable support films for electron microscopy

This disclosure provides systems, methods, and apparatus related to arrangements including electron microscopy grids. In one aspect an arrangement includes an electron microscopy grid. The electron microscopy grid comprises a first surface and a second surface, with the first surface having a holey carbon film disposed thereon. A plurality of lipid molecules are disposed in a hole in the holey carbon film. Each lipid molecule of the plurality of lipid molecules has a hydrophilic head and a hydrophobic tail. A biotin-binding protein is attached to the hydrophilic heads of the plurality of lipid molecules. The biotin-binding protein is crystalline.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methods and apparatus for preparing aqueous specimens for electron microscopy using volatile surfactants

This disclosure provides systems, methods, and apparatus related to the preparation of electron microscopy specimens. In one aspect, a method includes providing an electron microscopy grid. An aqueous suspension including an electron microscopy sample is deposited on the electron microscopy grid. A portion of the aqueous suspension is removed from the electron microscopy grid. A volatile surfactant is contacted to the aqueous suspension. A thickness of aqueous suspension is allowed to decrease over a period of time. The aqueous suspension is then frozen.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monolayer-crystal streptavidin support films provide an internal standard of cryo-EM image quality

Analysis of images of biotinylated Escherichia coli 70S ribosome particles, bound to streptavidin affinity grids, demonstrates that the image-quality of particles can be predicted by the image-quality of the monolayer crystalline support film. Also, the quality of the Thon rings is a good predictor of the image-quality of particles, but only when images of the streptavidin crystals extend to relatively high resolution. When the estimated resolution of streptavidin was 5 Å or worse, for example, the ribosomal density map obtained from 22,697 particles went to only 9.5 Å, while the resolution of the map reached 4.0 Å for the same number of particles, when the estimated resolution of streptavidin crystal was 4 Å or better. It thus is easy to tell which images in a data set ought to be retained for further work, based on the highest resolution seen for Bragg peaks in the computed Fourier transforms of the streptavidin component. The refined density map obtained from 57,826 particles obtained in this way extended to 3.6 Å, a marked improvement over the value of 3.9 Å obtained previously from a subset of 52,433 particles obtained from the same initial data set of 101,213 particles after 3-D classification. These results are consistent with the hypothesis that interaction with the air-water interface can damage particles when the sample becomes too thin. Finally, streptavidin monolayer crystals appear to provide a good indication of when that is the case.

59 BASIC BIOLOGICAL SCIENCES↗

Long shelf-life streptavidin support-films suitable for electron microscopy of biological macromolecules

We describe a rapid and convenient method of growing streptavidin (SA) monolayer crystals directly on holey-carbon EM grids. As expected, these SA monolayer crystals retain their biotin-binding function and crystalline order through a cycle of embedding in trehalose and, later, its removal. This fact allows one to prepare, and store for later use, EM grids on which SA monolayer crystals serve as an affinity substrate for preparing specimens of biological macromolecules. In addition, we report that coating the lipid-tail side of trehalose-embedded monolayer crystals with evaporated carbon appears to improve the consistency with which well-ordered, single crystals are observed to span over entire, 2 μm holes of the support films. Randomly biotinylated 70S ribosomes are used as a test specimen to show that these support films can be used to obtain a high-resolution cryo-EM structure

59 BASIC BIOLOGICAL SCIENCES↗

Factors that Influence the Formation and Stability of Thin, Cryo-EM Specimens

Poor consistency of the ice thickness from one area of a cryo-electron microscope (cryo-EM) specimen grid to another, from one grid to the next, and from one type of specimen to another, motivates a reconsideration of how to best prepare suitably thin specimens. We first review the three related topics of wetting, thinning, and stability against dewetting of aqueous films spread over a hydrophilic substrate. Furthermore, we then suggest that the importance of there being a surfactant monolayer at the air-water interface of thin, cryo-EM specimens has been largely underappreciated. In fact, a surfactant layer (of uncontrolled composition and surface pressure) can hardly be avoided during standard cryo-EM specimen preparation. Thus it is suggested that better control over the composition and properties of the surfactant layer may result in more reliable production of cryo-EM specimens with the desired thickness.

59 BASIC BIOLOGICAL SCIENCES↗

High Throughput Identification, Purification and Structural Characterization of Water Soluble Protein Complexes in Desulfovibrio vulgaris

Our scheme for the tagless purification of water soluble complexes. 10 g of protein from a crude bacterial extract is first fractionated by ammonium sulfate precipitation and then by a series of chromatographic steps: anion exchange (IEX), hydrophobic interaction (HIC), and finally size exclusion (Gel Filtration). Fractions from the last chromatography step are trypsin digested and peptides labeled with iTRAQ reagents to allow multiplexing and quantitation during mass spectrometric analysis. Elution profiles of identified proteins are then subjected to clustering analysis.

54 ENVIRONMENTAL SCIENCES↗