Search NASA⌕ Search

Engineering topics

Haney, M.

Publications and source records attributed to Haney, M..

Quick Look Report of Godiva U233 shot March 2022 Data Collection Activities

This report discussing the March 2022 irradiation of U233 on the Godiva critical assembly using burst mode and subsequent analysis of the fission products starting at 65 minutes post irradiation, and ending 12 days later. The Short-Lived Fission Product Yield (SLFPY) project is one of many efforts under the Nuclear Physics Multi-Lab and related Venture Project. The objective of the SLFPY project is to provide improved measurements of fission product yields for select nuclides. The SLFPY project consists of measurement and analysis campaigns. To produce fission data, samples of actinide material are irradiated in a high-flux neutron environment. These samples are quickly placed in front of a detection system where both gamma singles and coincidence spectra are collected as a function of time. Gamma spectroscopy is performed on the irradiated material on site near the irradiation facility, starting as soon as feasible after the irradiation and continuing for 7 days or longer. Following the data collection, time-dependent fission yield analyses are performed using gamma-ray spectroscopy. This document summarizes the measurement campaign performed March 21 - April 4, 2022 where sub-gram quantities of 233 U nitrate (UO 2 (NO 3 ) 2 ) were irradiated in the Godiva reactor. The Godiva burst #2076 conducted under experiment IER 504 had a temperature change of +156 degrees Celsius, lasted 13.32 microseconds, and had a reactivity of $\$$1.089. The targets consisted of uranium oxide solution deposited in a quartz tube and packed with quartz wool. The flame-sealed quartz ampoules were used to contain the uranium samples for the irradiation and count activities. On March 22, 2022, at 10:27:00 a.m. the three uranium ampoules, along with a witness foil pack, were irradiated in the Godiva critical assembly using burst mode operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Acousto-optic techniques for real SAR imaging

Recent advancements in the development of the Real Time Acousto-optic SAR Processor are presented. In particular, the technique for introducing the azimuth reference function into the processor via an acousto-optic Bragg cell is discussed. This approach permits the reference function to be stored in electronic memory, thus giving the processor the flexibility needed to adapt rapidly to changes in the radar/target geometry. The architecture is described and results are presented which show the applicability of the technique to both spot-light and strip-map SAR.

Haney, M.↗

Real-time synthetic aperture radar processing

Real-time acousto-optic SAR processors are described and experimentally demonstrated. SAR imaging is performed in one of the architectures by applying the signal to an acousto-optic device and correlating it with chirp signals recorded on an optical transparency by time integration on a CCD detector. In a different implementation, the imaging is preformed by interfering the light beams diffracted from two separate acousto-optic devices, one modulated the radar signal and the second by the reference chirp waveform.

Psaltis, D.↗

Programmable Real-Time Acousto-Optic/CCD SAR processor

The theory of operation of the Real-Time Acousto-Optic SAR Processor is reviewed and recent experimental results are presented. The results include a demonstration of the real-time imaging capability of the processor with simulated radar signals. An advanced version of this processor is then described in which a programmable reference function is entered via a second acousto-optic device to eliminate the need for a 2-D SLM. In this implementation the reference function is updated by electronic means to give the processor the flexibility to adapt rapidly to changes in the parameters of the radar/target geometry.

Haney, M.↗

Synthetic aperture radar imaging using acousto-optics and charge-coupled devices

The operating principles of an acoustooptic/CCD real-time SAR processor are described, and experimental results are presented. Particular consideration is given to time-and-space integrating processing, the range processor, and the azimuth processor. The interferometric detection scheme is examined in detail.

Psaltis, D.↗

SAS 3 observations of two X-ray transient events with precursors

SAS 3 has observed two unusual fast transient X-ray events from different sources, one lasting about 150 s and one, approximately 1500 s. Both events were preceded by precursor pulses which lasted a few seconds and which rose and fell in less than 0.4 s. The precursors were separated from the 'main' events by several seconds, during which no X-rays were detected. There are similarities between the two main events and X-ray bursts in both their temporal and spectral evolution. The spectra of the main events started out much softer than the spectra of the precursors, became harder as they approached maximum intensity, and softened as they decayed. In the 1500-s event, X-rays with energies greater than 10 keV were delayed by about 80 s compared with 1.5-6-keV X-rays. A blackbody fit to the spectral data of the main event of approximately 1500-s duration gives a maximum temperature of 29 million K and a radius for the emitting region of at least about 9 km (at a distance of 10 kpc); this is similar to the temperature and sizes found for several X-ray burst sources.

Hoffman, J. A.↗