Search NASA⌕ Search

Engineering topics

Hannon, Fay

Publications and source records attributed to Hannon, Fay.

Compact, high-power superconducting radio-frequency accelerators for environmental applications

Electron-beam irradiation has been proven to destructively reduce or eliminate a wide variety of organic chemicals, viruses and bacteria from wastewater, as well as reducing sulfur and nitrous oxides emission from coal-fired power plants. It is estimated that there are approximately 30,000 such particle accelerators in use worldwide for industrial processes including surface and bulk processing of material, medical sterilization, and environmental remediation. Maximum beam power from accelerators used in these applications is currently limited to less than 500 kW, and a higher beam power is needed to reduce treatment costs. The market availability of continuous-wave (CW) electron-beam accelerators with power of the order of ~100 kW is also very limited. Superconducting radio-frequency (SRF) linear accelerators (linacs) are commonly used at basic research laboratories throughout the world due to their exceptionally high efficiency as compared to current industrial varieties. Recent advances in cryogenics, SRF thin films and high-power magnetrons allow for the design of increasingly compact and efficient CW SRF electron linacs in the energy range 1-10 MeV, with up to 1 MW of beam power. A new class of compact, high-efficiency electron-beam accelerators may provide cost-effective solutions for a range of industrial and environmental remediation applications, particularly with respect to tackling one such class of contaminants so-called “forever chemicals”, including per- and polyfluoroalkyl substances (PFASs), which are ubiquitous in a wide range of products and for which there is currently no effective destruction technology. We have recently demonstrated the key technologies required for such accelerators by: 1) operating a Nb3Sn SRF accelerating cavity cooled by commercial cryocoolers up to an accelerating gradient of 12.4 MV/m and 2) demonstrating the phase-locking as well as a high-efficiency power combining scheme for industrial magnetron transmitters. In this presentation, we will introduce the principles and benefits of MW-class SRF linacs, based on the conduction-cooled SRF technology that we have demonstrated for environmental remediation. We propose the development of a 4 MeV, 20 kW prototype to be built at Jefferson Lab as a first accelerator demonstrator unit. We will also present the results from samples study on the effect of electron-beam irradiation on so-called “forever chemicals” such as 1,4-dioxane and PFAS, using an existing multi-purpose 10 MeV, low-power, CW SRF linac at Jefferson Lab.

Ciovati, Gianluigi↗

High efficiency normal conducting linac for environmental water remediation

A continuous wave (CW) electron accelerator for the treatment of industrial streams including an electron beam source, a modified high efficiency slot coupled cavity, at least one focusing magnet positioned surrounding the accelerator to contain the beam in the accelerator, an efficient radio frequency power supply means for supplying power of a radio frequency to the cavity to induce a TM01 accelerating mode in the cavity, an electron beam spreader or raster, a fixed magnet array or two-dimensional scanning magnet for deflecting the accelerated beam into a desired shape, and an exit window for extracting the deflected electron beam. The accelerator includes a graded-beta cavity to enable use with a low-power pulsed electron source. The accelerator benefits from a low wall-power loss accelerating cavity that is energized with efficient RF sources, enabling it to be operated in continuous wave mode.

Hannon, Fay↗

An e-beam irradiation beamline at Jefferson Lab for 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) remediation in wastewater

The Upgraded Injector Test Facility (UITF) at Jefferson Lab, providing a beam energy up to 10 MeV, is suitable for wastewater remediation research. To investigate the degradation of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS), widespread in wastewater and potential to be regulated in near future, a beamline for electron-beam irradiation has been designed, installed and successfully commissioned at the UITF. A solenoid with a peak axial magnetic field of up to 0.28 T and a raster were used to obtain a Gaussian beam profile with a transverse standard deviation of 15 mm. It was applied to irradiate 1,4-dioxane sample filled in the target cell that was designed to let the entire sample receive significant irradiation doses. The dose distribution and absorbed dose, few studied in the current publications, are necessary measures for the degradation mechanism investigation and have been innovatively achieved in this work using simulations which were calibrated with opti-chromic dosimeter rods directly exposed to the electron beam. This approach provides an important way for investigating the environmental remediation impact of electron-beam irradiation.

Li, Xi↗

Design and commissioning of an e-beam irradiation beamline at the Upgraded Injector Test Facility at Jefferson Lab

We report the Upgraded Injector Test Facility (UITF) at Jefferson Lab is a continuous-wave superconducting linear accelerator capable of providing an electron beam with energy up to 10 MeV. A beamline for electron-beam irradiation has been designed, installed and successfully commissioned at this facility, aimed at the degradation study of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) in wastewater treatment. A solenoid with a peak axial magnetic field of up to 0.28 T and a set of raster coils were used to obtain a Gaussian beam profile with a transverse standard deviation of ~ 15.0 mm at the target location. Monte-Carlo simulations using FLUKA were carried out to calculate the total absorbed dose and the dose distribution in the sample volume inside the target cell. The simulations were benchmarked experimentally by dosimetry mapping using optichromic dosimeters. The results of the irradiation experiments showed a ~ 95% reduction of 1,4-dioxane in ultra-pure water for a dose of 1 kGy, demonstrating the potential of electron-beam irradiation towards addressing growing challenges in environmental remediation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-current conduction cooled superconducting radio-frequency cryomodule

A high-current, compact, conduction cooled superconducting radio-frequency cryomodule for particle accelerators. The cryomodule will accelerate an electron beam of average current up to 1 ampere in continuous wave (CW) mode or at high duty factor. The cryomodule consists of a single-cell superconducting radio-frequency cavity made of high-purity niobium, with an inner coating of Nb3Sn and an outer coating of pure copper. Conduction cooling is achieved by using multiple closed-cycle refrigerators. Power is fed into the cavity by two coaxial couplers. Damping of the high-order modes is achieved by a warm beam-pipe ferrite damper.

Ciovati, Gianluigi↗

Generation of High-Charge Magnetized Electron Beams Consistent With JLEIC Electron Cooling Requirements

The proposed Jefferson Lab Electron-Ion Collider (JLEIC), currently under design, relies on electron cooling in order to achieve the desired luminosity. This includes an electron beam with >55 Mev, 3.2 nC bunches that cools hadron beams with energies up to 100 GeV. To enhance the cooling, the electron beam must be magnetized with a specific eigen-emittance partition. This paper explores the use of the Fermilab Accelerator Science and Technology (FAST) facility to demonstrate the generation of an electron beam with parameters consistent with those required in the JLEIC high-energy cooler. We demonstrate via simulations the generation of the required electron-beam parameters and perform a preliminary experiment to validate FAST capabilities to produce such beams.

43 PARTICLE ACCELERATORS↗

Fabrication and Radio Frequency Properties of 3-GHz SRF Cavities Coated with MgB 2

Magnesium diboride (MgB 2 ) is considered a potential material for superconducting radio frequency cavities. MgB 2 coated Cu cavity will allow for a higher operational temperature than a bulk Nb cavity because of the higher transition temperature of MgB 2 and the high thermal conductivity of Cu. Using the hybrid physical chemical vapor deposition technique, MgB 2 coatings were successfully achieved on the inner wall of 3-GHz Cu cavities. The surface and superconducting properties of the coatings were characterized using small samples on Cu plugs mounted at different locations of mock cavities. RF measurement of a MgB 2 coated single-cell 3-GHz test cavity was carried out and it showed superconducting transition at 36 K. Here, the quality factor of this test cavity was lower than expected due to poor connectivity and inclusion of Mg-Cu alloy in the MgB 2 coating.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗