Search NASA⌕ Search

Engineering topics

Hansen, Clifford W

Publications and source records attributed to Hansen, Clifford W.

At least 19 records

Simulation of one-minute power output from utility-scale photovoltaic generation systems.

We present an approach to simulate time-synchronized, one-minute power output from large photovoltaic (PV) generation plants in locations where only hourly irradiance estimates are available from satellite sources. The approach uses one-minute irradiance measurements from ground sensors in a climatically and geographically similar area. Irradiance is translated to power using the Sandia Array Performance Model. Power output is generated for 2007 in southern Nevada are being used for a Solar PV Grid Integration Study to estimate the integration costs associated with various utility-scale PV generation levels. Plant designs considered include both fixed-tilt thin-film, and single-axis-tracked polycrystalline Si systems ranging in size from 5 to 300 MW{sub AC}. Simulated power output profiles at one-minute intervals were generated for five scenarios defined by total PV capacity (149.5 MW, 222 WM, 292 MW, 492 MW, and 892 MW) each comprising as many as 10 geographically separated PV plants.

99 GENERAL AND MISCELLANEOUS↗

Final report for %22High performance computing for advanced national electric power grid modeling and integration of solar generation resources%22, LDRD Project No. 149016.

Design and operation of the electric power grid (EPG) relies heavily on computational models. High-fidelity, full-order models are used to study transient phenomena on only a small part of the network. Reduced-order dynamic and power flow models are used when analysis involving thousands of nodes are required due to the computational demands when simulating large numbers of nodes. The level of complexity of the future EPG will dramatically increase due to large-scale deployment of variable renewable generation, active load and distributed generation resources, adaptive protection and control systems, and price-responsive demand. High-fidelity modeling of this future grid will require significant advances in coupled, multi-scale tools and their use on high performance computing (HPC) platforms. This LDRD report demonstrates SNL's capability to apply HPC resources to these 3 tasks: (1) High-fidelity, large-scale modeling of power system dynamics; (2) Statistical assessment of grid security via Monte-Carlo simulations of cyber attacks; and (3) Development of models to predict variability of solar resources at locations where little or no ground-based measurements are available.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of PV performance models and their impact on project risk.

Photovoltaic systems are often priced in $/W{sub p}, where Wp refers to the DC power rating of the modules at Standard Test Conditions (1000 W/m{sup 2}, 25 C cell temperature) and $ refers to the installed cost of the system. However, the true value of the system is in the energy it will produce in kWhs, not the power rating. System energy production is a function of the system design and location, the mounting configuration, the power conversion system, and the module technology, as well as the solar resource. Even if all other variables are held constant, the annual energy yield (kWh/kW{sup p}) will vary among module technologies because of differences in response to low-light levels and temperature. Understanding energy yield is a key part of understanding system value. System performance models are used during project development to estimate the expected output of PV systems for a given design and location. Performance modeling is normally done by the system designer/system integrator. Often, an independent engineer will also model system output during a due diligence review of a project. A variety of system performance models are available. The most commonly used modeling tool for project development and due diligence in the United States is probably PVsyst, while those seeking a quick answer to expected energy production may use PVWatts. In this paper, we examine the variation in predicted energy output among modeling tools and users and compare that to measured output.

14 SOLAR ENERGY↗

Statistical criteria for characterizing irradiance time series.

We propose and examine several statistical criteria for characterizing time series of solar irradiance. Time series of irradiance are used in analyses that seek to quantify the performance of photovoltaic (PV) power systems over time. Time series of irradiance are either measured or are simulated using models. Simulations of irradiance are often calibrated to or generated from statistics for observed irradiance and simulations are validated by comparing the simulation output to the observed irradiance. Criteria used in this comparison should derive from the context of the analyses in which the simulated irradiance is to be used. We examine three statistics that characterize time series and their use as criteria for comparing time series. We demonstrate these statistics using observed irradiance data recorded in August 2007 in Las Vegas, Nevada, and in June 2009 in Albuquerque, New Mexico.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization, propagation and analysis of aleatory and epistemic uncertainty in the 2008 performance assessment for the proposed repository for radioactive waste at Yucca Mountain, Nevada.

The 2008 performance assessment (PA) for the proposed repository for high-level radioactive waste at Yucca Mountain (YM), Nevada, illustrates the conceptual structure of risk assessments for complex systems. The 2008 YM PA is based on the following three conceptual entities: a probability space that characterizes aleatory uncertainty; a function that predicts consequences for individual elements of the sample space for aleatory uncertainty; and a probability space that characterizes epistemic uncertainty. These entities and their use in the characterization, propagation and analysis of aleatory and epistemic uncertainty are described and illustrated with results from the 2008 YM PA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of methodologies for analysis of the dungeness B accidental aircraft crash risk.

The Health and Safety Executive (HSE) has requested Sandia National Laboratories (SNL) to review the aircraft crash methodology for nuclear facilities that are being used in the United Kingdom (UK). The scope of the work included a review of one method utilized in the UK for assessing the potential for accidental airplane crashes into nuclear facilities (Task 1) and a comparison of the UK methodology against similar International Atomic Energy Agency (IAEA), United States (US) Department of Energy (DOE), and the US Nuclear Regulatory Commission (NRC) methods (Task 2). Based on the conclusions from Tasks 1 and 2, an additional Task 3 would provide an assessment of a site-specific crash frequency for the Dungeness B facility using one of the other methodologies. This report documents the results of Task 2. The comparison of the different methods was performed for the three primary contributors to aircraft crash risk at the Dungeness B site: airfield related crashes, crashes below airways, and background crashes. The methods and data specified in each methodology were compared for each of these risk contributors, differences in the methodologies were identified, and the importance of these differences was qualitatively and quantitatively assessed. The bases for each of the methods and the data used were considered in this assessment process. A comparison of the treatment of the consequences of the aircraft crashes was not included in this assessment because the frequency of crashes into critical structures is currently low based on the existing Dungeness B assessment. Although the comparison found substantial differences between the UK and the three alternative methodologies (IAEA, NRC, and DOE) this assessment concludes that use of any of these alternative methodologies would not change the conclusions reached for the Dungeness B site. Performance of Task 3 is thus not recommended.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗