Search NASA⌕ Search

Engineering topics

Hansen, Robert S.

Publications and source records attributed to Hansen, Robert S..

Design and Evaluation of a Ring Tension Test Grip for Remote Mechanical Testing of Irradiated Tubular Specimens

Here, the ring tension test (RTT) is a mechanical testing method for determining bulk mechanical behavior in the circumferential or hoop direction for tubular materials. The test is especially useful for testing materials with anisotropic mechanical properties, such as zirconium alloys, which are commonly used as nuclear fuel cladding. Anisotropy requires direction-specific testing to determine the hoop strength. Historically, several RTT methods and grips have been used, each method has its strengths and weaknesses, and, in all cases, the measured strength is subject to uncertainty due to variations of the testing geometry and experimental tolerances. Recent analysis has shown that grips with a hemicylindrical mandrel configuration are recommended as the most robust configuration. The two strictest aspects to be controlled are the ability to determine gage region orientation and closely matching the size of the mandrels to the test specimen. This last requirement is particularly challenging when the dimensions of the specimen vary because of environmental effects such as dimensional changes due to irradiation. This paper presents a new RTT grip designed to incorporate this mandrel shape, hold the gage at the desired orientation, be suitable for remote operation in a hot-cell environment, and be adaptable for different sizes or variations in the specimen size. The general description and the unique design features of the test specimen and grips are given in detail. The performance of the grips in mechanical testing, including in a remote hot-cell environment, is also provided.

42 ENGINEERING↗

Evaluation of the ring tension test (RTT) for robust determination of material strengths

The ring tension test (RTT) is an experimental method for determining mechanical behavior in a material’s circumferential or hoop direction. It is a crucial test for testing anisotropic materials with tube geometry, such as nuclear fuel cladding or irradiated pipes. Several RTT configurations exist, each with their own advantages and disadvantages. However, this test is significantly more complex than traditional tensile testing and can be especially sensitive to small differences and inconsistencies in the test setup and geometry, ultimately affecting the derived mechanical properties. Previous research has focused on method development, and little work has been done on understanding the subtle differences between an ideal test and experiments, specifically when the tests are performed on highly irradiated materials in hot cells. In this work, a finite element-based investigation of the RTT is conducted to fill this gap. The two most used test configurations are investigated, comparing their ability to determine accurate material strengths through plastic deformation. Several non-ideal conditions and uncontrollable effects which are likely to occur during experimental testing such as machining tolerances, variations of specimen geometry from nominal dimensions, rotation of specimens and fixturing, and other test setup discrepancies are studied. The sensitivity of measured strengths to these conditions is presented. A mechanics-based approach to describing and correcting raw data to determine actual strengths is also included for one of the configurations, resulting in a robust correction method with highly accurate material strength measurements. Finally, based on these analyses, the hemicylindrical mandrel configuration is recommended with a gauge region oriented at a 45° angle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Resumption of water capsule reactivity-initiated accident testing at TREAT

A series of integral reactivity-initiated accident (RIA) commissioning experiments were completed in a new static water capsule in the Transient Reactor Test Facility (TREAT), marking the first such tests in the U.S. in more than 40 years. The test campaign included a verification test followed by five tests in the Static Environment Rodlet Transient Test Apparatus (SERTTA) capsule. The capsule initial conditions varied from room temperature and pressure up to 200°C and 2.5 MPa, with energy depositions varying between ~500–1100 J/gUO 2 . The series of tests allowed for a number of instrumentation qualifications and demonstrations, including cladding thermometry, rodlet plenum pressure, cladding elongation, and an electro-impedance boiling detector. Post transient examinations such as gamma emission spectroscopy, profilometry, and microscopy were performed to document the end state of the fuel rods. Furthermore, the results from the experiments show that the fuel rodlets behaved very similar to historical tests under similar energy depositions. This paper documents the design of the capsule and highlights some results from the commissioning tests and post-transient examination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗