Search NASA⌕ Search

Engineering topics

Hanson, Donald J.

Publications and source records attributed to Hanson, Donald J..

LDRD 227829: Multifunctional Composite LDRD: Radiation Effect on CeO 2 -HDPE Composites

Commercial high-density polyethylene (HDPE) is lightweight with excellent mechanical properties but has limited thermal stability. To enhance this, lanthanide-based nanomaterials like CeO 2 were mixed with HDPE. Using a twin-screw extruder improved dispersion. This study examines the effects of neutron, X-rays and gamma radiation on the crystallinity of polymer of CeO 2 -HDPE composites.

36 MATERIALS SCIENCE↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Structural Features of Zirconium-Based Metal–Organic Frameworks Affecting Radiolytic Stability

Metal–organic frameworks (MOFs) NU-1000 and UiO-66 are herein exposed to two different gamma irradiation doses and dose rates and analyzed to determine the structural features that affect their stability in these environments. MOFs have shown promise for the capture and sensing of off-gases at civilian nuclear energy reprocessing sites, nuclear waste repositories, and nuclear accident locations. However, little is understood about the structural features of MOFs that contribute to their stability levels under the ionizing radiation conditions present at such sites. This study is the first of its kind to explore the structural features of MOFs that contribute to their radiolytic stability. Both NU-1000 and UiO-66 are MOFs that contain Zr metal-centers with the same metal absorption cross section. However, the two MOFs exhibit different linker connectivities, linker aromaticities, node densities, node connectivities, and interligand separations. In this study, NU-1000 and UiO-66 were exposed to high (423.3 Gy/min, 23 min, and 37 s) and low (0.78 Gy/min, 4320 min) dose rates of 60 Co gamma irradiation. NU-1000 displayed insignificant radiation damage under both dose rates due to its high linker connectivity, low node density, and low node connectivity. However, low radiation dose rates caused considerable damage to UiO-66, a framework with lower aromaticity and smaller interligand separation. Finally, results suggest that chronic, low-radiation environments are more detrimental to Zr MOF stability than acute, high-radiation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Commercially Available Precursors for Obscuring Wet Industrial Irradiator Facility Pools to Delay Adversarial Source Removal (Part 2)

The behavior of commercially available potential obscurants for cobalt-60 ( 60 Co) wet-source storage industrial irradiator facilities (IRFs) were further evaluated for corrosive behavior of Nordion C-188 pencil stubs and obscurant properties under radiation exposure ( 60 Co). The potential obscurants studied included: titania aqueous dispersions (TAD - water soluble white paint), Chlorazol Black (CBOD - Chlorazol Black organic dye), powdered milk (COW - calcium obscurant in water), diatomaceous earth (DEA - diatomaceous earth additive), and rhodamine 6G (R6G). For corrosion efforts, stubs from an inert C-188 pencil-source rod were soaked in obscurant solutions and visually inspected. For radiation stability, obscurant samples were exposed to 60 Co radiation sources at 207 rad/s. The results from these studies reveal: the obscurants had no impact on the surrogate samples and may assist in terms of corrosion resistance; materials that did not rely on organic compounds to provide obscurance performed the best, as the organic compounds decomposed too rapidly in the high radiation environment, whereas the materials survived.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗