Relation between fundamental estimation limit and stability in linear quantum systems with imperfect measurement
From the noncommutative nature of quantum mechanics, estimation of canonical observables q and p is essentially restricted in its performance by the Heisenberg uncertainty relation, <{delta}q{sup 2}><{delta}p{sup 2}>{>=}({Dirac_h}/2{pi}){sup 2}/4. This fundamental lower bound may become bigger when taking the structure and quality of a specific measurement apparatus into account. In this paper, we consider a particle subjected to a linear dynamics that is continuously monitored with efficiency {eta}(set-membership sign)(0,1]. It is then clarified that the above Heisenberg uncertainty relation is replaced by <{delta}q{sup 2}><{delta}p{sup 2}>{>=}({Dirac_h}/2{pi}){sup 2}/4{eta} if the monitored system is unstable, while there exists a stable quantum system for which the Heisenberg limit is reached.