Search NASA⌕ Search

Engineering topics

Harkay, K C

Publications and source records attributed to Harkay, K C.

Electron Cloud at Low Emittance in CesrTA

The Cornell Electron Storage Ring (CESR) has been reconfigured as a test accelerator (CesrTA) for a program of electron cloud (EC) research at ultra low emittance. The instrumentation in the ring has been upgraded with local diagnostics for measurement of cloud density and with improved beam diagnostics for the characterization of both the low emittance performance and the beam dynamics of high intensity bunch trains interacting with the cloud. A range of EC mitigation methods have been deployed and tested and their effectiveness is discussed. Measurements of the electron cloud's effect on the beam under a range of conditions are discussed along with the simulations being used to quantitatively understand these results.

43 PARTICLE ACCELERATORS↗

Simulations of Electron-Cloud Current Density Measurements in Dipoles, Drifts And Wigglers at CesrTA

A core component of the CesrTA research program at Cornell is to fully understand the electron cloud effect through the use of simulation programs that have been developed to predict the growth of the cloud and its interaction with the beam. As a local probe of the electron cloud, several segmented retarding field analyzers (RFAs) have been installed in CesrTA in dipole, drift and wiggler regions. Using these RFAs, the energy spectrum of the time-average electron cloud current density striking the walls has been measured for a variety of bunch train patterns, with different bunch currents, beam energies, emittances, and bunch lengths, and for both positron and electron beams. This paper will compare these measurements with the predictions of simulation programs.

43 PARTICLE ACCELERATORS↗

Simulations of Electron-Cloud Current Density Measurements in Dipoles, Drifts, and Wigglers at CesrTA

A core component of the Cesr-TA research program at Cornell is to fully understand the electron cloud effect through the use of simulation programs that have been developed to predict the growth of the cloud and its interaction with the beam. As a local probe of the electron cloud, several segmented retarding field analyzers (RFAs) have been installed in CesrTA in dipole, drift and wiggler regions. Using these RFAs, the energy spectrum of the time-average electron cloud current density striking the walls has been measured for a variety of bunch train patterns, with different bunch currents, beam energies, emittances, and bunch lengths, and for both positron and electron beams. This paper will compare these measurements with the predictions of simulation programs.

43 PARTICLE ACCELERATORS↗

Laser-Driven Coherent Betatron Oscillation in a Laser-Wakefield Cavity

The origin of beam disparity in emittance and betatron oscillation orbits, in and out of the polarization plane of the drive laser of laser-plasma accelerators, is explained in terms of betatron oscillations driven by the laser field. As trapped electrons accelerate, they move forward and interact with the laser pulse. For the bubble regime, a simple model is presented to describe this interaction in terms of a harmonic oscillator with a driving force from the laser and a restoring force from the plasma wake field. The resulting beam oscillations in the polarization plane, with period approximately the wavelength of the driving laser, increase emittance in that plane and cause microbunching of the beam. These effects are observed directly in 3D particle-in-cell simulations.

43 PARTICLE ACCELERATORS↗

Observations of rising tune during the injection instability of IPNS RCS proton bunch.

In the rapid cycling synchrotron (RCS), a single proton bunch (h=1) is accelerated from 50 MeV to 450 MeV in approximately 14.2 ms. The bunch experiences an instability shortly after injection (<1 ms). During the first millisecond, the beam is bunched but little acceleration takes place; therefore this period is similar to a storage ring mode of operation. Natural vertical oscillations (assumed to be tune lines) show the vertical tune to be rising toward the bare tune value, suggesting neutralization of space charge and a reduction of its detuning effects. Neutralization time near injection ranges from 250 mus - 500 mus, depending on the background gas pressure. Oscillations move from the LSB to the USB before disappearing. Tune measurements made with a recently installed ferrite- magnet pinger system show the horizontal chromaticity to be positive early but approaching zero later in the cycle; on the other hand, the vertical chromaticity is negative throughout the cycle. During pinger studies near injection, two vertical lines are observed. Neutralization of the beam space charge implies the generation of plasma in the beam volume early in the cycle which may then dissipate as the time-varying electric fields of the beam become stronger.

43 PARTICLE ACCELERATORS↗

Vertical Instability at IPNS RCS.

The rapid cycling synchrotron (RCS) of the intense pulsed neutron source (IPNS) at ANL accelerates > 3.0 times 10{sup 12} protons from 50 MeV to 450 MeV with 30-Hz repetition frequency. During the acceleration cycle, the rf frequency varies from 2.21 MHz to 5.14 MHz. Presently, the beam current is limited by a vertical instability. By analyzing turn-by-turn beam position monitor (BPM) data, large- amplitude mode 0 and mode 1 vertical beam centroid oscillations were observed in the later part of the acceleration cycle. The oscillations start in the tail of the bunch, build up, and remain localized in the tail half of the bunch. This vertical instability was compared with a head-tail instability that was intentionally induced in the RCS by adjusting the trim sextupoles. It appears that our vertical instability is not a classical head-tail instability [1]. More data analysis and experiments were performed to characterize the instability.

43 PARTICLE ACCELERATORS↗

Planned Use of Pulsed Crab Cavities for Short X-Ray Pulse Generation at the Advanced Photon Source

Recently, we have explored application to the Advanced Photon Source (APS) of Zholents'[1] crab cavity scheme for production of short x-ray pulses. We assumed use of superconducting (SC) cavities in order to have a continuous stream of crabbed bunches and flexibility of operating modes. The challenges of the SC approach are related to the size, cost, and development time of the cavities and associated systems. A good case can be made [2] for a pulsed system using room-temperature cavities. APS has elected to pursue such a system in the near term, with the SC-based system planned for a later date. This paper describes the motivation for the pulsed system and gives an overview of the planned implementation and issues. Among these are overall configuration options and constraints, cavity design options, frequency choice, cavity design challenges, tolerances, instabilities, and diagnostics plans.

43 PARTICLE ACCELERATORS↗