Search NASA⌕ Search

Engineering topics

Harke, Kathryn J.

Publications and source records attributed to Harke, Kathryn J..

Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources

Time-integrated radiography using MeV Bremsstrahlung X-ray sources is the norm for imaging during system-level testing of components and structures under dynamic condition. One source of error in the analysis of the time-integrated radiography data sets stems from motion blur which smears out sharp interfaces to a greater degree with longer exposure times, which become necessary to provide sufficient signal-to-noise with low X-ray penetration of objects of interest. To quantify motion blur, a 1D shock wave through PMMA was investigated experimentally at The Dynamic Compression Sector at The Advanced Photon Source (DCS@APS) with tapered broadband and 25.46 ± 1.06 keV narrowband X-rays. Four cameras with different exposure times were used for each experiment to compare the effect that exposure time has on motion blur. In addition, our methodology to accurately simulate motion blur in terms of transmission and shape is presented and compared to our experimental results and quantified. There is a high level of agreement between the experimental and simulation results across the range of data sets investigated in this study with a percent difference range of 0.29–1.31% for the four shots. The methodology of this work serves as a steppingstone towards a physically validated model that could be used in conjunction with experimental results to deconvolve physical parameters, densities, and interfaces of interest in a way that would not be possible with experimental results alone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seal Strength Calculations for Low Mass DDT Vessel

Lawrence Livermore National Laboratory (LLNL) is collaborating with Colorado School of Mines (Mines), to field the first dynamic experiments on the 3-ring flash radiography system (3-ring). One set of experiments for 3-ring concerns the deflagration to detonation transition (DDT), within a sealed column of high-explosives. The high-explosive material is ignited at one end with a BK-80, an igniter made from Boron Potassium-Nitrate (BKNO 3 ). The initial deflagration reaction will increase the pressure in the sealed vessel, resulting in the formation of a dense "plug" of material ahead of the deflagration front. The transition to detonation is thought to be related to the plug formation. Previous experiments have been able to resolve the plug geometry, but only in a two dimensional radio-graph. 3-ring offers a novel diagnostic tool which could provide three dimensional density fields via few-view reconstruction algorithms and computed tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fused x-ray and fast neutron CT reconstruction for imaging large and dense objects

Megavolt x-ray computed tomography (CT) is a powerful tool for three-dimensional characterization. However, its utility is limited for large objects composed of high-atomic number (Z) materials, where x rays fail to penetrate. Information from fast neutron CT (FNCT) can complement x-ray CT reconstructions since fast neutrons can more readily penetrate high-Z objects. In this work, we demonstrate a method for combining FNCT and x-ray CT data to create a single reconstruction, more accurate than could be achieved with either x rays or fast neutrons alone. The algorithm was tested on an exemplar comprising multiple concentric, nested cylinders of different materials. Simulated and empirical x-ray CT data were acquired for the exemplar using a 9 MV bremsstrahlung spectrum. Additional simulated and empirical FNCT data were acquired using an accelerator based fast neutron source. The FNCT data were used to synthesize x-ray CT data and augment the x-ray CT data missing due to lack of penetration. This approach mitigates artifacts that would otherwise negatively affect the accuracy and resolution of a single-modality reconstructed volume.

47 OTHER INSTRUMENTATION↗

Real-time laser ultrasonic monitoring of laser-induced thermal processes

Abstract Intra- and inter-layer integrity of components fabricated with advanced manufacturing techniques, such as laser powder bed fusion, is dependent upon rapid heating, melting, and solidification processes. There is a need for new techniques to provide in situ feedback of these processes. Here a laser-based ultrasonic technique to probe thermal effects induced by a high-power continuous wave laser in titanium samples is described. Numerical simulations were performed to show that, for a spatially uniform heating beam, laser-induced surface acoustic waves are strongly influenced by surface heating conditions, are dispersive in the case of rapid heating, and that an abrupt velocity reduction happens upon the onset of surface melting. Furthermore, laser-based ultrasound experimental results which monitor the transient change of surface wave travel time associated with high power laser surface heating are provided. A pulsed laser is used to generate high frequency surface acoustic waves that propagate through the laser-heated region and are detected using a photorefractive crystal-based interferometer. Qualitative agreement is observed between theory and experiment with both showing a rapid reduction in the surface wave velocity at the onset of illumination and further decrease in surface wave velocity associated with melting. It is demonstrated that changes in the surface wave velocity can be used to track local heating and detect the onset of surface melting in real time.

36 MATERIALS SCIENCE↗