Search NASA⌕ Search

Engineering topics

Harman, Todd

Publications and source records attributed to Harman, Todd.

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Fluid dynamic and thermal performance of a slotted cylinder at low Reynolds number

The fluid dynamic and thermal performance of a circular cylinder with a slot parallel to the flow is numerically investigated. The study utilized the semi-implicit finite volume multi-material algorithm MPM-ICE, a component of the Uintah framework. The normalized slot width s/D ranges from 0.1 - 0.3, introducing an additional heat transfer surface area between ~ 10 and ~ 50%, and a mass reduction between ~ 13 and ~ 38% in the cylinder. We assumed two-dimensional incompressible flow and simulated a Reynolds number Re D between 100 and 1000. The slotted cylinders are found to have a total drag force reduction up to ~ 45%, compared to a solid cylinder despite the additional viscous drag force in the slot. Convection heat transfer is enhanced up to ~ 70%. Further, the slotted cylinder performance index, defined as the ratio of the heat rate to the drag force, increases up to maximum of ~ 3, indicating better overall thermal fluid performance. An entropy analysis showed the best performance index occurs at the highest Re D . Correlations for drag coefficient and Nusselt number are proposed along with an entropy optimization method.

42 ENGINEERING↗

Row spacing as a controller of solar module temperature and power output in solar farms

We report that when the temperature of solar photovoltaic modules rises, efficiency drops and module degradation accelerates. The spatial arrangement of solar modules can affect convective cooling and, consequently, module temperatures. However, the impact of row spacing on convective cooling in realistic solar farms has not yet been studied. Here, we develop six solar farm arrangements consisting of a fixed number of rows with varying streamwise row spacing. We model the flow and heat transfer of each solar farm using high-resolution large-eddy simulations. Results indicate that increasing row spacing can enhance convective cooling by 14.8%, which reduces module temperature by 6.6 °C and increases power output by 4.0% on average.

14 SOLAR ENERGY↗

Demonstrating GPU code portability and scalability for radiative heat transfer computations

High performance computing frameworks utilizing CPUs, Nvidia GPUs, and/or Intel Xeon Phis necessitate portable and scalable solutions for application developers. Nvidia GPUs in particular present numerous portability challenges with a different programming model, additional memory hierarchies, and partitioned execution units among streaming multiprocessors. This work presents modifications to the Uintah asynchronous many-task runtime and the Kokkos portability library to enable one single codebase for complex multiphysics applications to run across different architectures. Scalability and performance results are shown on multiple architectures for a globally coupled radiation heat transfer simulation, ranging from a single node to 16,384 Titan compute nodes.

Computer Science↗

Scalable Data Management of the Uintah Simulation Framework for Next-Generation Engineering Problems with Radiation

The need to scale next-generation industrial engineering problems to the largest computational platforms presents unique challenges. This paper focuses on data management related problems faced by the Uintah simulation framework at a production scale of 260K processes. Uintah provides a highly scalable asynchronous many-task runtime system, which in this work is used for the modeling of a 1000 megawatt electric (MWe) ultra-supercritical (USC) coal boiler. At 260K processes, we faced both parallel I/O and visualization related challenges, e.g., the default file-per-process I/O approach of Uintah did not scale on Mira. In this paper we present a simple to implement, restructuring based parallel I/O technique. We impose a restructuring step that alters the distribution of data among processes. The goal is to distribute the dataset such that each process holds a larger chunk of data, which is then written to a file independently. This approach finds a middle ground between two of the most common parallel I/O schemes–file per process I/O and shared file I/O–in terms of both the total number of generated files, and the extent of communication involved during the data aggregation phase. To address scalability issues when visualizing the simulation data, we developed a lightweight renderer using OSPRay, which allows scientists to visualize the data interactively at high quality and make production movies. Finally, this work presents a highly efficient and scalable radiation model based on the sweeping method, which significantly outperforms previous approaches in Uintah, like discrete ordinates. The integrated approach allowed the USC boiler problem to run on 260K CPU cores on Mira.

97 MATHEMATICS AND COMPUTING↗

An Integrated Approach to Scaling Task-Based Runtime Systems for Next Generation Engineering problems

The need to scale next-generation industrial engineering problems to the largest computational platforms presents unique challenges. Such problems may have complex coupled multi-physics models, as well as computationally and communication intensive algorithms not often seen in standard academic problems, while also needing high-demand I/O for analysis purposes. In such cases even codes with good existing scaling properties may need significant changes, addressed in a cross-cutting way to solve such problems at extreme scales. These challenges relate to system components that were not previously problematic on less complex problems and/or at smaller computational scales. This paper illustrates these challenges for Uintah, a highly scalable asynchronous many-task runtime system being applied to the modeling of a 1000 MWe ultra-supercritical coal boiler. In order to model this formidable, production engineering problem, not only was an integrated approach needed that built upon existing scalable components in areas such as complex stencil calculations and linear algebra, but the significant challenges of high demand I/O, complex task graphs, and infrastructure inefficiencies also had to be addressed. This integrated approach allowed this problem to run on 256K CPU cores on Mira, with good weak scaling to 512K CPU cores and similar strong scaling, except for radiation. The need for strong scaling of a new ray tracing-based radiation model required substantial Uintah infrastructure improvements before 119K CPU cores and 7.5K GPUs on Titan could be used, with scaling out to 256K CPU cores and 16K GPUs. The resulting code demonstrates not only excellent overall scalability but a significant improvement in overall performance for the full-scale, production boiler problem.

97 MATHEMATICS AND COMPUTING↗

Comprehensive Evaluation of Fast-Response, Reynolds-Averaged Navier–Stokes, and Large-Eddy Simulation Methods Against High-Spatial-Resolution Wind-Tunnel Data in Step-Down Street Canyons

Three computational fluid dynamics (CFD) methods with different levels of flow-physics modelling are comprehensively evaluated against high-spatial-resolution wind-tunnel velocity data from step-down street canyons (i.e., a short building downwind of a tall building). The first method is a semi-empirical fast-response approach using the Quick Urban Industrial Complex (QUIC-URB) model. The second method solves the Reynolds-averaged Navier–Stokes (RANS) equations, and the third one utilizes a fully-coupled fluid-structure interaction large-eddy simulation (LES) model with a grid-turbulence inflow generator. Unlike typical point-by-point evaluation comparisons, here the entire two-dimensional wind-tunnel dataset is used to evaluate the dynamics of dominant flow topological features in the street canyon. Each CFD method is scrutinized for several geometric configurations by varying the downwind-to-upwind building-height ratio (H d /H u ) and street canyon-width to building-width aspect ratio (S / W) for inflow winds perpendicular to the upwind building front face. Disparities between the numerical results and experimental data are quantified in terms of their ability to capture flow topological features for different geometric configurations. Ultimately, all three methods qualitatively predict the primary flow topological features, including a saddle point and a primary vortex. But, the secondary flow topological features, namely an in-canyon separation point and secondary vortices, are only well represented by the LES method despite its failure for taller downwind building cases. Misrepresentation of flow-regime transitions, exaggeration of the coherence of recirculation zones and wake fields, and overestimation of downwards vertical velocity into the canyon are the main defects in QUIC-URB, RANS and LES results, respectively. All three methods underestimate the updrafts and, surprisingly, QUIC-URB outperforms RANS for the streamwise velocity component, while RANS is superior to QUIC-URB for the vertical velocity component in the street canyon.

58 GEOSCIENCES↗

Packing Configurations of PBX-9501 Cylinders to Reduce the Probability of a Deflagration to Detonation Transition (DDT)

The detonation of hundreds of explosive devices from either a transportation or storage accident is an extremely dangerous event. This paper focuses on identifying ways of packing/storing arrays of explosive cylinders that will reduce the probability of a Deflagration to Detonation Transition (DDT). The Uintah Computational Framework was utilized to predict the conditions necessary for a large scale DDT to occur. The results showed that the arrangement of the explosive cylinders and the number of devices packed in a “box” greatly effects the probability of a detonation.

Chemistry↗