Search NASA⌕ Search

Engineering topics

Harrington, D. E.

Publications and source records attributed to Harrington, D. E..

Thrust performance of isolated, two-dimensional suppressed plug nozzles with and without ejectors at Mach numbers from 0 to 0.45

A series of two-dimensional plug nozzles was tested with and without ejector shrouds at free stream Mach numbers from 0 to 0.45 and over a range of nozzle pressure ratios from 2 to 4. These nozzles were also tested with and without chute noise suppressors. A two-dimensional plug nozzle has an efficiency of 96.1 percent at an assumed takeoff pressure ratio of 3.0 and Mach 0.36. A 12-chute suppressed nozzle with sidewalls has an efficiency of 81.0 percent (15.1 percent below the unsuppressed nozzle).

Harrington, D. E.↗

Thrust performance of isolated 36-chute suppressor plug nozzles with and without ejectors at Mach numbers from 0 to 0.45

Plug nozzles with chute-type noise suppressors were tested with and without ejector shrouds at free-stream Mach numbers from 0 to 0.45 and over a range of nozzle pressure ratios from 2 to 4. A 36-chute suppressor nozzle with an ejector had an efficiency of 94.6 percent at an assumed takeoff pressure ratio of 3.0 and a Mach number of 0.36. This represents only a 3.4 percent performance penalty when compared with the 98 percent efficiency obtained with a previously tested unsuppressed plug nozzle.

Harrington, D. E.↗

Cold-flow performance of several variations of a ram-air-cooled plug nozzle for supersonic-cruise aircraft

Experimental data were obtained with a 21.59 cm (8.5 in.) diameter cold-flow model in a static altitude facility to determine the thrust and pumping characteristics of several variations of a ram-air-cooled plug nozzle. Tests were conducted over a range of nozzle pressure ratios simulating supersonic cruise and takeoff conditions. Primary throat area was also varied to simulate afterburner on and off. Effect of plug size, outer shroud length, primary nozzle geometry, and varying amounts of secondary flow were investigated. At a supersonic cruise pressure ratio of 27, nozzle efficiencies were 99.7 percent for the best configurations.

Harrington, D. E.↗

Thrust performance of isolated plug nozzles with two types of 40-spoke noise suppressor at Mach numbers from 0 to 0.45

Plug nozzles with two types of 40-spoke noise suppressor were tested at free-stream Mach numbers from 0 to 0.45 and over a range of nozzle pressure ratios from 1.5 to 4.0. In additon, an unsuppressed plug nozzle and a Supersonic Tunnel Association nozzle were also tested to provide baseline levels of thrust performance. The unsuppressed plug nozzle had an efficiency of 98 percent at an assumed takeoff pressure ratio of 3.0 and at Mach 0.36. At the same condition the suppressor nozzles had efficiencies of approximately 83.5 percent.

Harrington, D. E.↗

Experimental cold-flow evaluation of a ram air cooled plug nozzle concept for afterburning turbojet engines

A concept for plug nozzles cooled by inlet ram air is presented. Experimental data obtained with a small scale model, 21.59-cm (8.5-in.) diameter, in a static altitude facility demonstrated high thrust performance and excellent pumping characteristics. Tests were made at nozzle pressure ratios simulating supersonic cruise and takeoff conditions. Effect of plug size, outer shroud length, and varying amounts of secondary flow were investigated.

Straight, D. M.↗