Strain Gauges Indicate Differential-CTE-Induced Failures

A method of detecting mechanical failure induced by variation in temperature at an adhesive bond between two materials that have different coefficients of thermal expansion (CTEs) involves monitoring of strain-gauge readings. This method can be regarded as an exploitation of the prior observation that the readings of strain gauges commonly used in tensile and compressive testing of material specimens include features indicative of incremental failures in the specimens. In this method, one or more strain gauges are bonded to either or both of the two materials near the bond between the materials. (The adhesive used to bond the strain gauges would not ordinarily be the same as the one used to bond the two materials). Then strain-gauge readings are recorded as the temperature of the materials is varied through a range of interest. Any significant discontinuity in the slope of the resulting strain-versus-temperature curve(s) is taken to be a qualitative indication of a failure of the bond between the two materials and/or a failure within one of the materials in the vicinity of the bond. The method has been demonstrated in experiments on specimens consisting of polyacrylonitrile-fiber/epoxy-matrix laminated composite plates bonded by epoxy to smaller plates made, variously, of aluminum, titanium, and a low-CTE nickel/iron alloy. In preparation for each experiment, strain gauges were bonded, by use of cryogenic-rated adhesives, to the composite plate near the corners of the metal plate (see Figure 1). In each experiment, strain-gauge and temperature readings were taken as the specimen was cooled from room temperature to 20 K. The specimens were then returned to room temperature and ultrasonically inspected for damage in the bond region. No failure events were detectable in the strain-gauge readings from the composite/ titanium and composite/low-thermalexpansion- alloy specimens, and ultrasonic inspection of these specimens revealed no damage. However, failure events were seen in the strain-gauge readings from the composite/aluminum specimens (see Figure 2), and ultrasonic inspection confirmed that there was damage in the bond regions of these specimens.

Harris, Brian↗

Cryogenic Durability of a Carbon Fiber Reinforced Cyanate Ester Composite: Degree-of-Cure Effect

The James Webb Space Telescope (JWST) will be located approximately 1.5 million kilometers from Earth, producing extremely cold temperatures on the optical portion of the observatory. Specifically, the Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) will operate at approximately -240 C. Construction of the structural components of the OTE and ISIM require bonding dissimilar materials together, e.g. Invar-36 (an iron-nickel alloy) to a carbon fiber reinforced cyanate ester composite (CFRCE) with an epoxy adhesive. While these materials enable the cryogenic stability required for optical performance, their joint strength at these extreme conditions presents a unique design challenge. Therefore, the current study presents a detailed investigation into the optimization of cryogenic composite durability. It is demonstrated that by controlling the degree-of-cure of a laminate, one can achieve an enhanced resistance to microcracking and an improved residual strength following cryogenic cycling to -253 C.

Polis, Daniel L.↗