Search NASA⌕ Search

Engineering topics

Harris, J. H.

Publications and source records attributed to Harris, J. H..

The Compelling Need for a Mid-Scale Stellarator Facility

In the pursuit of the goal of commercial fusion as an abundant and safe source of energy, the stellarator is a leading concept with compelling attractiveness and demonstrated performance. In this white paper we, as a community of US researchers from Universities, National Laboratories, and Private Industry, involved in studying the stellarator concept, lay out the programmatic and technical motivation for a new mid-size stellarator research facility in the US. This contribution is complementary to several other whitepapers authored by members of our community which address different mid-scale stellarator aspects. A community based technical facility proposal has been prepared by F. Parra, et al: Flexible Stellarator Physics Facility. Two private stellarator companies have submitted proposals supporting the development of a mid-scale stellarator: Thea Energy (C.P.S. Swanson, et al.), Type One Energy (W. Guttenfelder, et al.).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Compelling Need for a Mid-Scale Stellarator Facility

In the pursuit of the goal of commercial fusion as an abundant and safe source of energy, the stellarator is a leading concept with compelling attractiveness and demonstrated performance. A new mid-size stellarator is needed to retire risks and innovate towards a high performance, economically attractive, stellarator Fusion Pilot Plant. In this presentation we, as a community of US researchers from Universities, National Laboratories, and Private Industry, involved in studying the stellarator concept, lay out the programmatic and technical motivation for a new and modern mid-size stellarator research facility. A new mid-scale stellarator is needed to realize the potential predicted by a solid body of theory and simulation along with advances in computational tools for optimization and non-linear turbulence modeling. Notably, it is possible to combine the advantages of the stellarator (steady state, no current drive, no disruptions) with the good confinement regularly achieved in tokamaks. The top priorities for experimental work, and the motivation for a mid-scale stellarator experiment are: turbulence control, non-resonant divertor, MHD stability at large beta, confinement of fast particles, and coil simplification. A new mid-size quasi-symmetric stellarator, built as a user facility, would complement existing research at Wendelstein 7-X and LHD and strongly augment private industry. It would provide a program of innovative research, concept validation, theoretical advancement, and workforce development. Growing support and interest for stellarators by the fusion community and private industry affirms this rationale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First feedback-controlled divertor detachment in W7-X: Experience from TDU operation and prospects for operation with actively cooled divertor

In the last experimental campaign (OP1.2b) of the stellarator Wendelstein 7-X (W7-X), boronisation as a mean for first wall conditioning was applied for the first time which led to strongly reduced impurity fluxes from plasma-facing components. Thermal detachment at the uncooled target plates of the test divertor unit (TDU) was reached at higher plasma densities and was accompanied by high recycling of neutrals at the target plate. A feedback control system was established in W7-X to actively control the gas injection (actuator) for plasma fuelling and impurity seeding [3] through the divertors. It allowed very successful stabilisation of the detached plasma condition state as well as mitigation of thermal overloads to some baffle tiles. Different routinely available diagnostic signals were used as input parameters (sensors). We describe the setup of the feedback control system, its performance and provide some example results with the main focus on the development of the control scheme which led to the detachment stabilisation over the entire longest (30 s) high-power discharge at W7-X so far. In view of the achieved very successful detachment stabilisation and the necessity to include simultaneous optimisation of the core performance in the future, the feedback control system is being upgraded for the upcoming campaign (OP2.1) in which the water cooled and hereby inherently steady-state capable divertor has been currently installed. The prospects and some experiment ideas for active detachment control are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a Continuous Pellet Fueling System for Wendelstein 7-X

A continuous pellet fueling system (CPFS) is currently being designed at the Oak Ridge National Laboratory (ORNL) for the long pulse operation of the Wendelstein 7-X (W7-X) stellarator. The purpose of the CPFS is to provide deep continuous fueling for feedback-controlled high-density operation and mitigation of predicted hollow density profiles. As described here, the system will provide the capability to inject cylindrical pellets of solid hydrogen or deuterium into the plasma core, with flexibility to vary the pellet size, velocity, and injection frequency. Pellets are nominally of 3 mm in diameter and have a length between 1 and 4 mm. The heart of the CPFS is a vertically oriented, twin-screw extruder, cooled by three Gifford-McMahon cryocoolers in parallel, designed to form a continuous filament of hydrogen or deuterium. The filament width, which determines the pellet length, can be adjusted by means of a variable nozzle driven by a linear actuator at the base of the extruder. Coupled to the nozzle is a solenoid-operated gas gun and cutter assembly. A pneumatic propellant valve pulses a burst of ~60 bar helium to accelerate the cut pellet into W7-X. Three gaps in the guide tubes provide pumping locations to remove the helium propellant before it reaches the plasma. The maximum velocity of the pellet is limited by its ability to survive navigating the guide tube trajectory intact. A microwave cavity located within the guide tube provides the capability to measure the pellet size and velocity. The mechanical and thermal designs of the W7-X extruder, adjustable nozzle, and gun and cutter assembly design are described. A guide tube design and experimental pellet survivability test results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First results from the implementation of the ITER diagnostic residual gas analyzer prototype at Wendelstein 7-X

Fusion reactors and long pulse fusion experiments heavily depend on a continuous fuel cycle, which requires detailed monitoring of exhaust gases. We have used a diagnostic residual gas analyzer (DRGA) built as a prototype for ITER and integrated it on the most advanced stellarator fusion experiment, Wendelstein 7-X (W7-X). The DRGA was equipped with a sampling tube and assessed for gas time of flight sample response, effects of magnetic field on gas detection and practical aspects of use in a state of the art fusion environment. The setup was successfully commissioned and operated and was used to observe the gas composition of W7-X exhaust gases. The measured time of flight gas response was found to be in the order of a second for a 7 m sample tube. High values of magnetic field were found to affect the partial pressure readings of the DRGA and suggest that additional shielding is necessary in future experimental campaigns.

47 OTHER INSTRUMENTATION↗

Stellarator Research Opportunities: A Report of the National Stellarator Coordinating Committee

This document is the product of a stellarator community workshop, organized by the National Stellarator Coordinating Committee and referred to as Stellcon, that was held in Cambridge, Massachusetts in February 2016, hosted by MIT. The workshop was widely advertised, and was attended by 40 scientists from 12 different institutions including national labs, universities and private industry, as well as a representative from the Department of Energy. The final section of this document describes areas of community wide consensus that were developed as a result of the discussions held at that workshop. Areas where further study would be helpful to generate a consensus path forward for the US stellarator program are also discussed. The program outlined in this document is directly responsive to many of the strategic priorities of FES as articulated in ‘‘Fusion Energy Sciences: A Ten-Year Perspective (2015–2025)’’ [1]. The natural disruption immunity of the stellarator directly addresses ‘‘Elimination of transient events that can be deleterious to toroidal fusion plasma confinement devices’’ an area of critical importance for the US fusion energy sciences enterprise over the next decade. Another critical area of research ‘‘Strengthening our partnerships with international research facilities,’’ is being significantly advanced on the W7-X stellarator in Germany and serves as a test-bed for development of successful international collaboration on ITER. This report also outlines how materials science as it relates to plasma and fusion sciences, another critical research area, can be carried out effectively in a stellarator. Additionally, significant advances along two of the Research Directions outlined in the report; ‘‘Burning Plasma Science: Foundations—Next-generation research capabilities’’, and ‘‘Burning Plasma Science: Long pulse—Sustainment of Long-Pulse Plasma Equilibria’’ are proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of magnetic islands in the plasma edge on particle fueling and exhaust in the HSX and W7-X stellarators

The edge magnetic structure in the Helically Symmetric eXperiment (HSX) and Wendelstein 7X (W7-X) stellarators has been shown to have a significant impact on the particle fueling and exhaust of the plasma main species (hydrogen) as well as impurity helium. For HSX, the plasma sourcing to exhaust ratio, quantified by the effective and global particle confinement times τ p * and τ p , H , respectively, increases when a magnetic island chain is located in the plasma edge. The fueling efficiency is reduced by 25% when the plasma boundary is deformed by the magnetic islands. The X-point geometry also yields higher plasma temperatures in front of the main recycling region. When the island is moved radially inward, both τ p * and τ p decrease by 10 % – 25 % depending on plasma density. The τ p , H results rely heavily on EMC3-EIRENE modeling which confirms reduced fueling efficiency due to more rapid ionization in the outward shifted island position. These findings suggest that for a helically optimized system like HSX, the plasma fueling from the recycling source, as well as from active gas injection, can be controlled by the magnetic island chain in the plasma edge—which is a basic requirement for a divertor system. This process is also effective for the control of effective helium exhaust times, as τ p , H e * measured by perturbative gas puff experiments is reduced by up to 40% when the islands are shifted inwards. For Wendelstein 7-X, a similar reduction of τ p , H e * was inferred when magnetic islands were moved from the far plasma edge into the confined plasma region. Finally, however, the effective confinement features of H as the main plasma species were not affected due to the non-optimal position of the magnetic islands with respect to the highly localized ionization domain during the limiter startup campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Confinement in Wendelstein 7-X Limiter Plasmas

Observations on confinement in the first experimental campaign on the optimized Stellarator Wendelstein 7-X are summarized. In this phase W7-X was equipped with five inboard limiters only and thus the discharge length restricted to avoid local overheating. Stationary plasmas are limited to low densities <2–3 centerdot 10 19 m -3 . With the available 4.3 MW ECR Heating core T e ~ 8 keV, T i ~ 1–2 keV are achieved routinely resulting in energy confinement time τ E between 80 ms to 150 ms. For these conditions the plasmas show characteristics of core electron root confinement with peaked T e -profiles and positive E r up to about half of the minor radius. Lastly, profiles and plasma currents respond to on- and off-axis heating and co- and counter ECCD respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of visible spectroscopy diagnostics for W sources assessment in WEST

The present work concerns the development of a W sources assessment system in the framework of the tungsten-W environment in steady state tokamak project that aims at equipping the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFCs) in view of preparing ITER operation. The goal is to assess W sources and D recycling with spectral, spatial, and temporal resolution adapted to the PFCs observed. The originality of the system is that all optical elements are installed in the vacuum vessel and compatible with steady state operation. Our system is optimized to measure radiance as low as 10{sup 16} Ph/(m{sup 2} s sr). A total of 240 optical fibers will be deployed to the detection systems such as the “Filterscope,” developed by Oak Ridge National Laboratory (USA) and consisting of photomultiplier tubes and filters, or imaging spectrometers dedicated to Multiview analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma response measurements of non-axisymmetric magnetic perturbations on DIII-D via soft x-ray imaging

Recent observations on DIII-D have advanced the understanding of plasma response to applied resonant magnetic perturbations (RMPs) in both H-mode and L-mode plasmas. Three distinct 3D features localized in minor radius are imaged via filtered soft x-ray emission: (i) the formation of lobes extending from the unperturbed separatrix in the X-point region at the plasma boundary, (ii) helical kink-like perturbations in the steep-gradient region inside the separatrix, and (iii) amplified islands in the core of a low-rotation L-mode plasma. In this study, these measurements are used to test and to validate plasma response models, which are crucial for providing predictive capability of edge-localized mode control. In particular, vacuum and two-fluid resistive magnetohydrodynamic(MHD) responses are tested in the regions of these measurements. At the plasma boundary in H-mode discharges with n = 3 RMPs applied, measurements compare well to vacuum-field calculations that predict lobe structures. Yet in the steep-gradient region, measurements agree better with calculations from the linear resistive two-fluid MHD code, M3D-C1. Relative to the vacuum fields, the resistive two-fluid MHD calculations show a reduction in the pitch-resonant components of the normal magnetic field (screening), and amplification of non-resonant components associated with ideal kink modes. However, the calculations still over-predict the amplitude of the measuredperturbation by a factor of 4. In a slowly rotating L-mode plasma with n = 1 RMPs, core islands are observed amplified from vacuum predictions. Finally, these results indicate that while the vacuum approach describes measurements in the edge region well, it is important to include effects of extended MHD in the pedestal and deeper in the plasma core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing the plasma near high power wave launchers in fusion devices for static and dynamic electric fields (invited)

An exploratory study was carried out in the long-pulse tokamak Tore Supra, to determine if electric fields in the plasma around high-power, RF wave launchers could be measured with non-intrusive, passive, optical emission spectroscopy. The focus was in particular on the use of the external electric field Stark effect. The feasibility was found to be strongly dependent on the spatial extent of the electric fields and overlap between regions of strong (>∼1 kV/cm) electric fields and regions of plasma particle recycling and plasma-induced, spectral line emission. Most amenable to the measurement was the RF electric field in edge plasma, in front of a lower hybrid heating and current drive launcher. Electric field strengths and direction, derived from fitting the acquired spectra to a model including time-dependent Stark effect and the tokamak-range magnetic field Zeeman-effect, were found to be in good agreement with full-wave modeling of the observed launcher.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-axisymmetric equilibrium reconstruction for stellarators, reversed field pinches and tokamaks

Axisymmetric equilibrium reconstruction using magnetohydrodynamic equilibrium solutions to the Grad Shafranov equation has long been an important tool for interpreting tokamak experiments. This paper describes recent results in non-axisymmetric (three-dimensional) equilibrium reconstruction of nominally axisymmetric plasmas (tokamaks and reversed field pinches (RFPs)), and fully non-axisymmetric plasmas (stellarators). Results from applying the V3FIT code to CTH and HSX stellarator plasmas, RFX-mod RFP plasmas and the DIII-D tokamak are presented.

Hanson, James D.↗

Lessons Learned in Risk Management on NCSX

The National Compact Stellarator Experiment (NCSX) was designed to test physics principles of an innovative stellarator design developed by the Princeton Plasma Physics Laboratory and Oak Ridge National Laboratory. Construction of some of the major components and sub-assemblies was completed, but the estimated cost and schedule for completing the project grew as the technical requirements and risks became better understood, leading to its cancellation in 2008. The project's risks stemmed from its technical challenges, primarily the complex component geometries and tight tolerances that were required. The initial baseline, established in 2004, was supported by a risk management plan and risk-based contingencies, both of which proved to be inadequate. Technical successes were achieved in the construction of challenging components and subassemblies, but cost and schedule growth was experienced. As part of an effort to improve project performance, a new risk management program was devised and implemented in 2007-08. It led to a better understanding of project risks, a sounder basis for contingency estimates, and improved management tools. Although the risks ultimately were unacceptable to the sponsor, valuable lessons in risk management were learned through the experiences with the NCSX project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗