Search NASA⌕ Search

Engineering topics

Harris, John R.

Publications and source records attributed to Harris, John R..

Application of a radial radio-frequency electron gun to waste treatment

Electron-beam irradiation has been shown to be a clean, efficient, and effective technique for treating a variety of contaminants in a variety of media. In particular, the ionizing radiation produced by an electron beam can effectively decontaminate wastewater and aid in removing harmful chemicals from industrial flue gas. In this paper, we investigate a novel technique for waste treatment using an electron-beam system in which an (approximately) annular beam converges radially into the treatment volume. We provide preliminary system-level analysis of the design of a radial electron gun, and we discuss hypothetical system constructs in which a radial electron gun is used for treatment of flue gas and wastewater. We derive dose uniformity, throughput rates, and other important treatment parameters for each application. Our results suggest that a lower-energy system with a large-radius cylindrical treatment volume is preferable for flue gas treatment, whereas a higher-energy system with an annular treatment volume is better-suited for wastewater treatment.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Performance estimates for a multicube retroreflector design

Here, we describe a novel type of retroreflector, which we call a “multicube” retroreflector, optimized to provide improved optical power return when a large number of retroreflectors are dispersed through a volume or on a surface. While it does not match the performance of a “multiplane cross” type retroreflector on an individual level, it offers improved performance compared to a standard corner cube while retaining the corner cube’s advantages: fabrication via stamping, and the ability to densely pack the retroreflectors. When dispersed as part of a cloud of retroreflectors, the multicube design provides significant performance improvements over both simple corner cubes and “multiplane cross” retroreflectors.

47 OTHER INSTRUMENTATION↗

Multi-plate interceptive electron beam energy diagnostic—Implementation and validation

A previous publication [P. D. McChesney, “Multi-plate interceptive electron beam energy diagnostic—Theoretical design,” AIP Adv. (submitted)] reported a new interceptive electron beam kinetic energy measurement technique based on the beam penetration depth within a stack of conductive plates and gave results on the theoretical design of such a device. This paper expands on this and gives further results on the actual implementation of the diagnostic. The device geometry and measurement electronics system are described in detail. A prototype version of the multi-plate diagnostic was fabricated and tested using an electron linear accelerator at the Idaho Accelerator Center (IAC). A high-precision magnetic spectrometer system was designed and built for the purpose of validating the multi-plate diagnostic’s energy measurement capabilities. It was found that the diagnostic provides electron beam energy estimates that are accurate to better than the 10% level.

43 PARTICLE ACCELERATORS↗

Observation of multipath effects in the detection of RF-modulated x-rays

As part of the Air Force Research Laboratory’s ongoing research in particle accelerators and beams, we recently began investigating the interaction of RF-modulated x-ray beams with RF structures. Additionally, these bremsstrahlung x-rays, produced using an S-band RF electron linac and tungsten foil, were able to drive RF signals at the linac frequency and its integer harmonics in an S-band waveguide. This was interpreted as a result of secondary electron production inside the waveguide by the modulated x-ray beam and implied that the primary electron beam RF modulation was preserved, to at least some degree, through both the processes of x-ray and secondary electron production. The strength of these signals induced on the waveguide varied as the distance of the waveguide from the tungsten foil changed, with the nature of these changes suggesting the existence of an interference process resulting from multipath propagation of the modulated x-rays. Here, we report on our initial attempt to verify this multipath propagation by altering the configuration of shielding and reflective masses in the environment of the waveguide. Finally, these measurements support the existence of a multipath propagation effect and further indicate that the RF modulation of the x-rays is preserved as they undergo scattering events inside the accelerator vault.

43 PARTICLE ACCELERATORS↗

Conceptual Design Report: Radial RF Injectors for Improved Waste Stream Processing

In June 2017, the US Department of Energy Accelerator Stewardship Program [1] released its “FY2017 Research Opportunities in Accelerator Stewardship” [2], including a call for design studies of four types of high-power electron accelerators for energy and environmental applications. Table 1 lists the target performance for the “Type 1” and “T ype 2” accelerators in this call.

54 ENVIRONMENTAL SCIENCES↗

Photonic Crystal-Based High-Power Backward Wave Oscillator

An electron beam traversing a slow wave structure can be used to either generate or amplify electromagnetic radiation through the interaction of the slow space charge wave on the beam with the slow wave structure modes. Here, a cylindrical waveguide with a periodic array of conducting loops is used for the slow wave structure. This paper considers operation as a backward wave oscillator. The dispersion properties of the structure are determined using a frequency-domain eigenmode solver. The interaction of the electron beam with the structure modes is investigated using a 2-D particle-in-cell (PIC) code. In conclusion, the operating frequency and growth rate dependence on beam energy and beam current are investigated using the PIC code and compared with analytic and scaling estimates where possible.

42 ENGINEERING↗

2D/3D image charge for modeling field emission

Analytic image charge approximations exist for planar and spherical metal surfaces but approximations for more complex geometries, such as the conical and wirelike structures characteristic of field emitters, are lacking. Such models are the basis for the evaluation of Schottky lowering factors in equations for current density. The development of a multidimensional image charge approximation, useful for a general thermal-field emission equation used in space charge studies, is given and based on an analytical model using a prolate spheroidal geometry. A description of how the model may be adapted to be used with a line charge model appropriate for carbon nanotube and carbon fiber field emitters is discussed. [http://dx.doi.org/10.1116/1.4968007]

47 OTHER INSTRUMENTATION↗

Discrete space charge affected field emission: Flat and hemisphere emitters

Models of space-charge affected thermal-field emission from protrusions, able to incorporate the effects of both surface roughness and elongated field emitter structures in beam optics codes, are desirable but difficult. The models proposed here treat the meso-scale diode region separate from the micro-scale regions characteristic of the emission sites. The consequences of discrete emission events are given for both one-dimensional (sheets of charge) and three dimensional (rings of charge) models: in the former, results converge to steady state conditions found by theory (e.g., Rokhlenko et al. [J. Appl. Phys. 107, 014904 (2010)]) but show oscillatory structure as they do. Surface roughness or geometric features are handled using a ring of charge model, from which the image charges are found and used to modify the apex field and emitted current. The roughness model is shown to have additional constraints related to the discrete nature of electron charge. The ability of a unit cell model to treat field emitter structures and incorporate surface roughness effects inside a beam optics code is assessed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗