Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C 3 F 8 dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. Here, the PICO collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C 3 F 8 from calibration data taken with five distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov chain Monte Carlo routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be ≥ 50% for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be ≥ 50% for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated datasets are used to calculate a p value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results on photon-mediated dark-matter–nucleus interactions from the PICO-60 C 3 F 8 bubble chamber

Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using nonrelativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 and 24 GeV/c 2 and above 265 GeV/c 2 (anapole moment), 2.7 and 11.7 GeV/c 2 (electric moment), 3 and 9.5 GeV/c 2 (magnetic moment), and 2.7 and 12 GeV/c 2 (millicharged) are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C 3 F 8 operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

A high-resolution Fourier-transform infrared spectrometer.

We have developed a Fourier-transform infrared spectrometer having a resolution of 0.5/cm over the range of wavelength from 1 to 5.5 microns. It has been used to observe the sun over this wavelength range from a Lear Jet flying at an altitude of 14 km, and to observe a number of stars from the ground, using the 229-cm telescope of the Steward Observatory and the 152-cm aluminum-mirror telescope at the Observatorio Astronomico Nacional in the Sierra de San Pedro Martir, Baja California, Mexico. The solar spectrum is given here, while the ground-based spectra are being published separately.