On the Necessity and Feasibility of an Equatorial Magnetospheric Constellation

Synthesizing multi-point in-situ observations from the magnetosphere is the only way that we can retain an accurate knowledge of the driving mechanisms of convection and energy flow while "imaging" its vast volume. In addition to measuring the wavenumber of plasma instabilities thus opening up for study a previously unexplored domain of space plasma physics the Constellation mission can afford us a view of the rapid topological reconfigurations and the energy circulation throughout the astrophysical laboratory closest to human space activity. In this paper we argue that the deployment of approximately 80 autonomous micro-satellites (probes) to monitor the Earth's magnetosphere and measure the plasma and magnetic field in the near-equatorial magnetosphere is a necessary and sufficient condition for answering long standing, high priority questions regarding magnetospheric stability and dynamics. The proposed mission concept is technically feasible and fiscally modest. The probes can be raised from a Geosynchronous Transfer orbit to their final elliptical orbits with perigee approximately 3R(sub E)and apogees ranging from 12 to 42 R(sub E) by a single dispenser propelled by an ion engine. Each probe will weigh approximately 5 kg. The mission can form a cornerstone of an incrementally deployed Solar Terrestrial Probe Line Magnetospheric Constellation, as it requires no new technologies in the areas of spacecraft subsystems and instruments, but some development in the areas of dispenser design, probe packaging, mechanical release and spin-up. The technology developed can be utilized by follow-on Constellation class missions as well.

Angelopoulos, V.

A high-resolution gamma-ray and hard X-ray spectrometer for solar flare observations in Max 1991

A long duration balloon flight instrument for Max 1991 designed to study the acceleration of greater than 10 MeV ions and greater than 15 keV electrons in solar flares through high resolution spectroscopy of the gamma ray lines and hard X-ray and gamma ray continuum is described. The instrument, HIREGS, consists of an array of high-purity, n-type coaxial germanium detectors (HPGe) cooled to less than 90 K and surrounded by a bismuth germanate (BGO) anticoincidence shield. It will cover the energy range 15 keV to 20 MeV with keV spectral resolution, sufficient for accurate measurement of all parameters of the expected gamma ray lines with the exception of the neutron capture deuterium line. Electrical segmentation of the HPGe detector into a thin front segment and a thick rear segment, together with pulse-shape discrimination, provides optimal dynamic range and signal-to-background characteristics for flare measurements. Neutrons and gamma rays up to approximately 0.1 to 1 GeV can be detected and identified with the combination of the HPGe detectors and rear BGO shield. The HIREGS is planned for long duration balloon flights (LDBF) for solar flare studies during Max 1991. The two exploratory LDBFs carried out at mid-latitudes in 1987 to 1988 are described, and the LDBFs in Antarctica, which could in principle provide 24 hour/day solar coverage and very long flight durations (20 to 30 days) because of minimal ballast requirements are discussed.

Lin, R. P.

A possible detection of Jupiter's northern auroral S1(1) H2 quadrupole line emission

An upper limit is presently determined for the mean intensity of the Jupiter northern Auroral UV/thermal hot spot's S1(1) H2 quadrupole emission, over an 8 sq arcsec illuminated beam; the value obtained is 4.2 X 10 to the -6th W/sq m per sr. It is suggested that the nonradiative deexitation of the H2 molecules via collisions with H may have been underestimated by Kim and Maguire (1986), due to uncertainties concerning auroral H density.

Trafton, L.

Solid-State dc Circuit Breaker

Circuit breaker with no moving parts protects direct-current (dc) loads. Current which circuit breaker opens (trip current) is adjustable and so is time delay before breaker trips. Forward voltage drop rises from 0.6 to 1.2 V as current rises to trip point. Breaker has two terminals, like fuse, therefore replaces fuse in dc circuit. Powered by circuit it protects and reset by either turning off power source or disconnecting load.

Harvey, P.

The energetics of molecular clouds. IV - The S88 molecular cloud

The S88 molecular cloud has been observed in several molecular lines and at infrared wavelengths from 1 to 100 microns. The CO emission has a single, sharp peak which is near the H-alpha emission region S88 B and centered on a compact H II region observed in the radio continuum. The infrared observations indicate that the principal luminosity source is located near the radio continuum peak and is hidden behind substantial extinction, presumably from the molecular cloud. The molecular cloud has a size of about 6.5 pc and a mass of about 5,000 solar masses at an assumed distance of 2 kpc. Regions of very high density (more than 10,000/cu cm) do not seem to be present. Analysis of the energetics leads to a predicted dust cooling rate in good agreement with the infrared observations, which indicate L = 180,000 solar luminosities. A more detailed examination of the energetics indicates that densities may be insufficient for collisions of molecules with warm dust grains to heat the gas to the observed kinetic temperature.

Evans, N. J., II

Infrared studies of the S235 molecular cloud

Infrared observations from 7.8 to 200 microns have been obtained for the S235 molecular cloud. Far-infrared maps were obtained for a region of active star formation, as marked by the presence of compact H II regions, water masers, and compact near-infrared sources. The primary heating source for the far-infrared emission appears to be the compact H II region, S235A. Detailed examination of the gas energetics in the region supports the plausibility of the picture in which the gas is heated by collisions with warm dust grains. The ratio of far-infrared optical depth to (C-13)O column density is somewhat lower in this source than is commonly found. This effect may be caused by the presence of substantial (C-13)O in regions where the dust is not warm enough to emit substantial 50-100 micron radiation.

Evans, N. J., II

Imaging Proportional X-ray Counter for HEAO

The HEAO-B Imaging Proportional Counter (IPC) is an X-ray imaging instrument designed for use in the High Energy Astronomy Observatory - Mission B (HEAO-B) X-ray Telescope. It measures the spatial location of individual X-ray photons by the risetime method and energy of photons by pulse height analysis. The IPC can locate photons in the energy range 0.2 to 4 keV to within 1 mm and provides 5 bits of energy level information. Each measured X-ray event is also time tagged with 7 bits of temporal data. The IPC also includes an in-flight-calibration source and uses a gas control system that maintains the counter gas density constant to an accuracy of 0.25 percent.

Humphrey, A.

Planetary investigation utilizing an imaging spectrometer system based upon charge injection technology

An intrinsic silicon charge injection device (CID) television sensor array has been used in conjunction with a CaMoO4 colinear tunable acousto optic filter, a 61 inch reflector, a sophisticated computer system, and a digital color TV scan converter/computer to produce near IR images of Saturn and Jupiter with 10A spectral resolution and approximately 3 inch spatial resolution. The CID camera has successfully obtained digitized 100 x 100 array images with 5 minutes of exposure time, and slow-scanned readout to a computer. Details of the equipment setup, innovations, problems, experience, data and final equipment performance limits are given.

Wattson, R. B.