Search NASA⌕ Search

Engineering topics

Hasan, Mahmudul

Publications and source records attributed to Hasan, Mahmudul.

Dilute Regeneration-Driven Membrane Capacitive Deionization of Synthetic Seawater Using Nanopatterned Membranes and Prussian Blue Analog Electrodes

Membrane capacitive deionization (MCDI) offers energy-efficient seawater desalination but is limited at high salinity by membrane resistance and incomplete electrode regeneration. Nanopatterned ion-exchange membranes, dilute regeneration protocols, and Prussian blue analog (PBA)-functionalized electrodes are combined in a flow-by-MCDI cell. Nanopatterned ion-exchange membranes (hexagonal, octagonal, double-ring, rectangular) enhance interfacial ion transport, with hexagonal geometry delivering ≈12.5% greater surface area and the best performance. PBA-functionalized electrodes increase salt adsorption and charge-transfer kinetic rates. The integrated system lowers the area-specific resistance by 45 Ω cm2, resulting in a 500 mV reduction in the cell voltage for a current density of 2 mA cm−2 for a 35 000 ppm NaCl feed. This improves the energy-normalized salt adsorption six fold (64–382 mmol J−1). Low salinity (2000 ppm) and mixed-salt regeneration sustains a ≈39% water recovery and stable performance for at least seven cycles. Overall, combining nanopatterned membranes, which promote confinement-enhanced ion mobility, and PBA electrodes, which enhance salt adsorption, improved the energy efficiency of MCDI.

Hasan, Mahmudul↗

Reducing Ohmic Resistances in Membrane Capacitive Deionization Using Micropatterned Ion-Exchange Membranes, Ionomer Infiltrated Electrodes, and Ionomer-Coated Nylon Meshes

Membrane capacitive deionization (MCDI) is an emerging water desalination platform that is compact, electrified, and does not require high-pressure piping. Herein, highly conductive poly(phenylene alkylene) ion-exchange membranes (IEMs) are micropatterned with different surface geometries for MCDI. The micropatterned membranes increase the interfacial area with the liquid stream leading to a 700 mV reduction in cell voltage when operating at constant current (2 mA cm -2 ; 2000 ppm NaCl feed) while improving the energy normalized adsorbed salt (ENAS) value by 1.4 times. Combining the micropatterned poly(phenylene alkylene) IEMs with poly(phenylene alkylene) ionomer-filled electrodes reduces the cell voltage by 1000 mV and improves the ENAS values by 2.3 times relative to the base case. This reduction in cell voltage allows for higher current density operation (i.e., 3–4 mA cm -2 ) . The reduction in cell voltage is ascribed to the ameliorating ohmic resistances related to ion transport at the membrane-process stream interface and in the carbon cloth electrode. Finally, porous ionic conductors are implemented into the spacer channel with flat and micropatterned IEM configurations and ionomer infiltrated electrodes. For the configuration with flat IEMs, the porous ionic conductor improves ENAS values across the current density regime (2–4 mA cm -2 ), while for micropatterned IEMs it gets improved only at 4 mA cm -2 .

42 ENGINEERING↗

Mass-selected ion–molecule cluster beam apparatus for ultrafast photofragmentation studies

We describe an apparatus for investigating the excited-state dissociation dynamics of mass-selected ion–molecule clusters by mass-resolving and detecting photofragment-ions and neutrals, in coincidence, using an ultrafast laser operating at high repetition rates. The apparatus comprises a source that generates ion–molecule clusters, a time-of-flight spectrometer, and a mass filter that selects the desired anions, and a linear-plus-quadratic reflectron mass spectrometer that discriminates the fragment anions after the femtosecond laser excites the clusters. The fragment neutrals and anions are then captured by two channeltron detectors. The apparatus performance is tested by measuring the photofragments: I – , CF 3 I – , and neutrals from photoexcitation of the ion–molecule cluster CF 3 I·I – using femtosecond UV laser pulses with a wavelength of 266 nm. Here, the experimental results are compared with our ground state and excited state electronic structure calculations as well as the existing results and calculations, with particular attention to the generation mechanism of the anion fragments and dissociation channels of the ion–molecule cluster CF 3 I·I – in the charge-transfer excited state.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electron Scattering from 1-Methyl-5-Nitroimidazole: Cross-Sections for Modeling Electron Transport through Potential Radiosensitizers

In this study, we present a complete set of electron scattering cross-sections from 1-Methyl-5-Nitroimidazole (1M5NI) molecules for impact energies ranging from 0.1 to 1000 eV. This information is relevant to evaluate the potential role of 1M5NI as a molecular radiosensitizers. The total electron scattering cross-sections (TCS) that we previously measured with a magnetically confined electron transmission apparatus were considered as the reference values for the present analysis. Elastic scattering cross-sections were calculated by means of two different schemes: The Schwinger multichannel (SMC) method for the lower energies (below 15 eV) and the independent atom model-based screening-corrected additivity rule with interferences (IAM-SCARI) for higher energies (above 15 eV). The latter was also applied to calculate the total ionization cross-sections, which were complemented with experimental values of the induced cationic fragmentation by electron impact. Double differential ionization cross-sections were measured with a reaction microscope multi-particle coincidence spectrometer. Using a momentum imaging spectrometer, direct measurements of the anion fragment yields and kinetic energies by the dissociative electron attachment are also presented. Cross-sections for the other inelastic channels were derived with a self-consistent procedure by sampling their values at a given energy to ensure that the sum of the cross-sections of all the scattering processes available at that energy coincides with the corresponding TCS. This cross-section data set is ready to be used for modelling electron-induced radiation damage at the molecular level to biologically relevant media containing 1M5NI as a potential radiosensitizer. Nonetheless, a proper evaluation of its radiosensitizing effects would require further radiobiological experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An AI-driven microstructure optimization framework for elastic properties of titanium beyond cubic crystal systems

Materials design aims to identify the material features that provide optimal properties for various engineering applications, such as aerospace, automotive, and naval. One of the important but challenging problems for materials design is to discover multiple polycrystalline microstructures with optimal properties. This paper proposes an end-to-end artificial intelligence (AI)-driven microstructure optimization framework for elastic properties of materials. In this work, the microstructure is represented by the Orientation Distribution Function (ODF) that determines the volume densities of crystallographic orientations. The framework was evaluated on two crystal systems, cubic and hexagonal, for Titanium (Ti) in Joint Automated Repository for Various Integrated Simulations (JARVIS) database and is expected to be widely applicable for materials with multiple crystal systems. The proposed framework can discover multiple polycrystalline microstructures without compromising the optimal property values and saving significant computational time.

36 MATERIALS SCIENCE↗