Search NASA⌕ Search

Engineering topics

Hastings, J. B.

Publications and source records attributed to Hastings, J. B..

At least 19 records

Second-order microscopic nonlinear susceptibility in a centrosymmetric material: application to imaging valence electron motion

We report measurements of phase-matched nonlinear x-ray and optical sum-frequency generation from single-crystal silicon using sub-resonant 0.95 eV laser pulses and 9.5 keV hard x-ray pulses from the LCLS free-electron laser. The sum-frequency signal appears as energy and momentum sidebands to the elastic Bragg peak. It is proportional to the magnitude squared of the relevant temporal and spatial Fourier components of the optically induced microscopic charges/currents. We measure the first- and second-order sideband to the 220 Bragg peak and find that the efficiency is maximized when the applied field is along the reciprocal lattice vector. For an optical intensity of $\sim10^{12} \text{W}/\text{cm}^2$, we measure peak efficiencies of $3\times 10^{-7}$ and $3\times 10^{-10}$ for the first and second-order sideband respectively (relative to the elastic Bragg peak). The first-order sideband is consistent with induced microscopic currents along the applied electric field (consistent with an isotropic response). The second-order sideband depends nontrivially on the optical field orientation and is consistent with an anisotropic response originating from induced charges along the bonds with C$_{3v}$ site symmetry. The results agree well with first-principles Bloch-Floquet calculations.

FOS: Physical sciences↗

Speed of sound in methane under conditions of planetary interiors

We present direct observations of acoustic waves in warm dense matter. We analyze wave-number- and energy-resolved x-ray spectra taken from warm dense methane created by laser heating a cryogenic liquid jet. X-ray diffraction and inelastic free-electron scattering yield sample conditions of 0.3 ± 0.1 eV and 0.8 ± 0.1 g/ cm − 3 , corresponding to a pressure of ∼ 13 GPa. Inelastic x-ray scattering was used to observe the collective oscillations of the ions. With a highly improved energy resolution of ∼ 50 meV, we could clearly distinguish the Brillouin peaks from the quasielastic Rayleigh feature. Data at different wave numbers were utilized to derive a sound speed of 5.9 ± 0.5 km/s, marking a high-temperature data point for methane and demonstrating consistency with Birch's law in this parameter regime. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structural changes across thermodynamic maxima in supercooled liquid tellurium: a water-like scenario

Liquid polymorphism is an intriguing phenomenon which has been found in a few single-component systems, the most famous being water. By supercooling liquid Te to more than 130 K below its melting point and performing simultaneous small-angle and wide-angle X-ray scattering measurements, we observe clear maxima in its thermodynamic response functions around 615 K, suggesting the possible existence of liquid polymorphism. A close look at the underlying structural evolution shows the development of intermediate-range order upon cooling, most strongly around the thermodynamic maxima, which we attribute to bond-orientational ordering. The striking similarities between our results and those of water, despite the lack of hydrogen-bonding and tetrahedrality in tellurium, indicate that water-like anomalies may be a general phenomenon among liquid systems with competing bond- and density-ordering.

36 MATERIALS SCIENCE↗

Anomalous two-photon Compton scattering

Abstract X-ray free-electron lasers can generate radiation pulses with extreme peak intensities at short wavelengths. This enables the investigation of laser–matter interactions in a regime of high fields, yet at a non-relativistic ponderomotive potential, where ordinary rules of light–matter interaction may no longer apply and nonlinear processes are starting to become observable. Despite small cross-sections, first nonlinear effects in the hard x-ray regime have recently been observed in solid targets, including x-ray-optical sum-frequency generation (XSFG), x-ray second harmonic generation (XSHG) and two-photon Compton scattering (2PCS). Nonlinear interactions of bound electrons in the x-ray range are fundamentally different from those dominating at optical frequencies. Whereas in the optical regime nonlinearities are predominantly caused by anharmonicities of the atomic potential in the chemical bonds, x-ray nonlinearities far above atomic resonances are expected to be due to nonlinear oscillations of quasi-free electrons, including inner-shell atomic electrons. While the quasi-free-electron model agrees reasonably well with the experimental data for XSFG and XSHG, 2PCS measurements have led to unexpected results: the energy of the nonlinearly scattered photons from non-relativistic electrons shows a substantial unexpected red shift in addition to the Compton shift that is well beyond that predicted by a nonlinear quantum electrodynamics model for free electrons. A potential explanation for the spectral broadening is based on a previously unexplored scattering process that involves the whole atom rather than just quasi-free electrons. A first simulation that includes the atomic binding potential was successful in describing a broadening of the spectrum of the nonlinearly scattered photons to longer wavelengths for soft x-rays. However, the same model does not show any broadening at hard x-ray wavelengths, which is in agreement with other simulation approaches. To this point no calculation has been able to reproduce the experimentally observed broadening. Here we present further experimental data of 2PCS for an extended parameter range using additional diagnostics. In particular, we present measurements of the electron momentum distribution during the interaction that strongly suggest that the spectral broadening is not caused by an increased plasma temperature. We extend our measurement of the magnitude of the red shift in beryllium to > 1.9 k e V in addition to the Compton shift expected for free electrons and expand the measurement of the angular distribution to include forward scattering angles. We also present first measurements of 2PCS from diamond.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An approach for the measurement of the bulk temperature of single crystal diamond using an X-ray free electron laser

We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray free electron laser using inelastic X-ray scattering. The experiment was performed at the high energy density instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within 8% for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state and transport models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An approach for the measurement of the bulk temperature of single crystal diamond using an X-ray Free Electron Laser

We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray Free Electron Laser using inelastic X-ray scattering. The experiment was performed at the High Energy Density (HED) instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within 8% for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reply to: Reconsidering X-ray plasmons

In this response we show a spectral and X-ray intensity analysis that unequivocally proves a spectrally resolved plasmon reported in ref. 1. The analysis takes the f-sum rules into account, is consistent with the independently and simultaneously measured wavenumber-resolved X-ray scattering signal and compares well with advanced elastic feature modelling, including density functional theory for molecular dynamics (DFTMD) as well as pseudoatom molecular dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasmon scattering probing of electronic states in diamond at extreme conditions

Here, we measured the collective plasmon scattering spectrum from diamond at pressures approaching 370 GPa. Samples are dynamically compressed employing counter-propagating laser beams where the compression states are determined by Bragg scattering. X-ray energy loss spectroscopy with 8 keV photons from the Linac Coherently Light Source (LCLS) is then applied to probe the electronic state. The x-rays excite a collective interband transition, leading to a clear plasmon signal whose dispersion matches density functional theory. The data reveal a pressure-dependent Penn gap and demonstrate a non-conducting warm dense matter state for conditions of planetary interiors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Energy Density science at the Linac Coherent Light Source

The Matter in Extreme Conditions end station at the Linac Coherent Light Source holds great promise for novel pump-probe experiments to make new discoveries in high- energy density science. Recently, our experiments have demonstrated the first spectrally- resolved measurements of plasmons using a seeded 8-keV x-ray laser beam. Forward x-ray Thomson scattering spectra from isochorically heated solid aluminum show a well-resolved plasmon feature that is down-shifted in energy by 19 eV from the incident 8 keV elastic scattering feature. In this spectral range, the simultaneously measured backscatter spectrum shows no spectral features indicating observation of collective plasmon oscillations on a scattering length comparable to the screening length. Moreover, this technique is a prerequisite for Thomson scattering measurements in compressed matter where the plasmon shift is a sensitive function of the free electron density and where the plasmon intensity provides information on temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Band gap opening in strongly compressed diamond observed by x-ray energy loss spectroscopy

The extraordinary mechanical and optical properties of diamond are the basis of numerous technical applications and make diamond anvil cells a premier device to explore the high-pressure behavior of materials. However, at applied pressures above a few hundred GPa, optical probing through the anvils becomes difficult because of the pressure-induced changes of the transmission and the excitation of a strong optical emission. Such features have been interpreted as the onset of a closure of the optical gap in diamond, and can significantly impair spectroscopy of the material inside the cell. In contrast, a comparable widening has been predicted for purely hydrostatic compressions, forming a basis for the presumed pressure stiffening of diamond and resilience to the eventual phase change to BC8. We here present the first experimental evidence of this effect at geo-planetary pressures, exceeding the highest ever reported hydrostatic compression of diamond by more than 200 GPa and any other measurement of the band gap by more than 350 GPa. We here apply laser driven-ablation to create a dynamic, high pressure state in a thin, synthetic diamond foil together with frequency-resolved x-ray scattering as a probe. The frequency shift of the inelastically scattered x-rays encodes the optical properties and, thus, the behavior of the band gap in the sample. Using the ultra-bright x-ray beam from the Linac Coherent Light Source (LCLS), we observe an increasing direct band gap in diamond up to a pressure of 370 GPa. This finding points to the enormous strains in the anvils and the impurities in natural Type Ia diamonds as the source of the observed closure of the optical window. Our results demonstrate that diamond remains an insulating solid to pressures approaching its limit strength.

36 MATERIALS SCIENCE↗