Search NASA⌕ Search

Engineering topics

Hatte, S.

Publications and source records attributed to Hatte, S..

Novel solid-infused durable nonwetting surfaces for sustained condensation heat transfer enhancement

Here, in this article, we report novel nonwetting solid-infused surfaces that are easily fabricated using industrially widely adopted methods such as chemical etching or electrodeposition and exhibit sustained dropwise condensation performance durably than superhydrophobic and lubricant-infused surfaces. Solid-infused surfaces demonstrate fourfold larger condensation heat transfer coefficient and 25% better condensation effectiveness when compared to superhydrophobic surface and conventional filmwise condensation. Although the condensation heat transfer coefficient of lubricant-infused surface initially matches that of solid-infused surface, it is shown through durability studies that the wettability characteristic that underpins the performance of lubricant-infused surfaces degrades quickly with time as the lubricant depletes and lubricant-infused surface transitions to superhydrophobic surface. Solid-infused surface, on the other hand, retains its steadfast superior dropwise condensation effectiveness in the long run, overcoming the challenges of droplet pinning, surface inundation, cloaking, and lubricant depletion that eventually deteriorate condensation on conventional nonwetting superhydrophobic and lubricant-infused surfaces.

42 ENGINEERING↗

Novel nonwetting solid-infused surfaces for superior fouling mitigation

Fouling is a ubiquitous issue in several environmental and energy applications. Here we introduce novel nonwetting solid-infused surfaces (SIS) with superior anti-fouling characteristics that are durable than conventional nonwetting surfaces in a dynamic flow environment. A systematic study is presented to elucidate the fouling mitigation performance of SIS in comparison to lubricant-infused surface (LIS) and conventional smooth surface. Copper tubes with SIS, LIS or smooth inner walls are fabricated and subjected to accelerated calcium sulfate fouling in a flow fouling experimental setup. Fouling on the various surface types is quantified in terms of asymptotic fouling resistance, and the fundamental morphological differences in the interactions of the foulant and the various surface types are analyzed. Based on a systematic sweep of the parameter combinations using design of experiments and Taguchi analysis, an analytical dependence of asymptotic fouling resistance on the governing parameters namely, Reynolds number, foulant concentration and temperature is derived. The analytical model is shown to predict the asymptotic fouling resistance to within 20% accuracy with a 95% confidence. In addition, for the first time, the effects of shear durability on the fouling mitigation performance of LIS vis-à-vis SIS are studied. It is shown that the novel nonwetting SIS offers a robust option for superior fouling mitigation over LIS in the long run.

42 ENGINEERING↗

Analysis of silica fouling on nonwetting surfaces

Ground water sources used as coolant fluids in a variety of thermal systems such as heat exchangers and power plant condensers contain silica particles that accrete on heat transfer surfaces over time leading to reduction in thermal performance, a problem that is particularly exacerbated with temperature. Nonwetting superhydrophobic, lubricant-infused, and a new class of solid-infused surfaces introduced in this work are candidates for fouling mitigation, by virtue of their water repellency, but little is known about fouling of silica on the surfaces, especially under dynamic flow conditions and as a function of temperature. This article presents, for the first time, a systematic study of dynamic flow fouling of silica on nonwetting surfaces vis-à-vis conventional copper surface over a temperature range 20–50°C. The mechanism of silica aggregate formation and its adherence to the different surfaces is elucidated by scanning electron microscope (SEM) imaging. Sigmoidal growth model is used to describe the time evolution of fouling thermal resistance and an Arrhenius model is presented for the temperature-dependent increase in the asymptotic fouling resistance on nonwetting and conventional surfaces alike. Lubricant-infused and solid-infused surfaces are shown to reduce fouling thermal resistance by up to 25% and 13%, respectively, compared to a conventional surface, whereas superhydrophobic surfaces lose their non-wettability under flow conditions, leading to an adverse increase in the fouling resistance by up to 13%. Considering the possible lubricant depletion in lubricant-infused surfaces over prolonged exposure to a flowing fluid, solid-infused surfaces present a robust alternative.

42 ENGINEERING↗

Generalized Analysis of Dynamic Flow Fouling on Heat Transfer Surfaces

Several energy applications involve flow of untreated heat transfer fluids that contain trace amounts of mineral salts, such as calcium carbonate and calcium sulfate, which show reverse solubility with temperature. The gradual accretion of these salts onto the heat transfer surfaces causes fouling that degrades thermal performance over time. While fouling of bare surfaces has been extensively studied, fouling of nonwetting superhydrophobic or liquid-infused surfaces is less understood, especially under dynamic flow conditions. This study presents a systematic experimental analysis to elucidate dynamic flow fouling of calcium carbonate and calcium sulfate on smooth, superhydrophobic and liquid-infused surfaces in a generalized manner. Here, copper tubes with modified inner surface wettability are fabricated and subjected to forced convection at different flow rates and fouling salt concentrations. Fouling characteristics of the two salts on the different surfaces are examined through microstructural analysis, and quantified in terms of asymptotic fouling resistance that measures the total extent of fouling, and a threshold time, which correlates to the onset of significant fouling. Using Taguchi design of experiments, the study reports, for the first time, closed-form analytical relationships for the asymptotic fouling thermal resistance and threshold time on the Reynolds number, dimensionless concentration of fouling agent and dimensionless infused liquid viscosity that represents the different surface types in a unified manner. It is shown that the analytical model accurately predicts the fouling characteristics in up to about 97% of the data, based on which contour maps of optimum surface designs for minimizing fouling resistance are presented. The results provide information on designing surfaces for reduced fouling or for estimating the fouling characteristics for a given surface in applications.

36 MATERIALS SCIENCE↗

Analysis of convection heat transfer on multiscale rough superhydrophobic and liquid infused surfaces

Multiscale rough superhydrophobic or slippery liquid infused porous surfaces have gained much interest in recent years for their improved transport phenomena properties. While there have been several studies on drag reduction and condensation on non-wetting surfaces, convection heat transfer that is important in many thermal and thermochemical applications has not been addressed systematically. Here, this article utilizes a fractal description of rough surface topographies to develop analytical models for the Nusselt number and the thermal hydraulic factor for fluid flow and heat transfer inside a cylinder with non-wetting surfaces. For air-infused superhydrophobic surfaces, the model considers the dynamic stability of the air/fluid interface in the asperities. Using the analytical formulations and the stability criteria, systematic studies are presented on the effects of the fractal surface parameters, cylinder radius and Reynolds number on the convective heat transfer characteristics, from which surface texture design maps are developed for maximizing the convection heat transfer. It is shown that multiscale non-wetting surfaces are most effective in the range of lower Reynolds number and small cylinder radius for achieving the best convective heat transfer and thermal hydraulic performance. Applying the models to actual non-wetting surface topographies fabricated using electrodeposition and chemical etching, it is shown that contrary to prevailing notion, superhydrophobicity, characterized by the highest contact angles, does not always lead to the maximum convective heat transfer performance, and that under certain fluid flow conditions, hydrophobic surfaces may offer a greater thermal performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Laminar Convective Heat Transfer Over Structured Non-Wetting Surfaces

Structured non-wetting surfaces provide alternating no-slip and partial slip boundary conditions to the fluid flow which, in turn, affects the convective heat transfer performance over the surfaces. In this work, an analytical model is developed for the interfacial Nusselt number, the overall Nusselt number and a thermal hydraulic performance factor for fluid flow in a cylinder patterned with structured non-wetting surfaces, for the two cases of uniform wall heat flux and uniform wall temperature. In addition, by considering the stability of the Cassie state of wettability and its transition to the Wenzel state for flow over superhydrophobic surfaces, the present model overcomes certain limitations of the previously reported studies in the literature. Based on the analytical formulations and the stability constraints, the present paper provides optimum design maps for tailoring structured non-wetting surfaces for maximizing convective heat transfer and the combined thermal-hydraulic performance in applications. Use of the design maps on example cases is also discussed. It is shown that the use of structured non-wetting surfaces is most effective for low Reynolds numbers and/or small cylinder radius.

42 ENGINEERING↗

Analytical model for drag reduction on liquid-infused structured non-wetting surfaces

Liquid-infused structured non-wetting surfaces provide alternating no-slip and partial slip boundary conditions to the fluid flow, resulting in reduced friction at the interface. In this paper, an analytical model is developed for the evaluation of effective slip and, in turn, friction factor and drag reduction on liquid-infused structured non-wetting surfaces. By considering the entire range of anisotropy and heterogeneity of the surface structures as well as the full range of partial slip offered by the infusion liquid, the present model eliminates empirical fitting or correlations that are inherent in previous studies. Based on the effective slip length, drag reduction and skin friction coefficient values for Newtonian flow between two infinite parallel plates and flow in round tubes are presented. Extension of Moody charts for non-wetting surfaces and design maps of surface meso/micro/nano texturing for achieving desired drag reduction are presented for a broad range of engineering applications. The paper further presents independent validation of the model across experimental and computational data from the literature and brings together several previous studies in a unified manner.

36 MATERIALS SCIENCE↗

Fractal Model for Drag Reduction on Multiscale Nonwetting Rough Surfaces

Rough surfaces in contact with a flow of fluid exhibit alternating no-slip and free shear boundary conditions at the solid–liquid and air–liquid interfaces, respectively, thereby potentially offering drag reduction benefits. The balance between the dynamic pressure in the flow and the restoring capillary pressure in the interasperity spaces determines the stability of the Cassie state of wettability and is a function of the relative extent of no-slip and free shear regions per unit surface area. In the present study, using a fractal representation of rough surface topography, an analytical model is developed to quantify the stability of the Cassie state of wettability as well as drag reduction and the friction factor for laminar flow in a rectangular channel between nonwetting multiscale rough surfaces. A systematic study is conducted to quantify the effects of fractal parameters of the surfaces and the flow Reynolds number on drag reduction and the friction factor. The studies are used to develop friction factor curves extending the classical Moody diagram to hydrophobic and superhydrophobic surfaces. On the basis of the studies, regime maps are derived for estimating the extent of drag reduction offered by hydrophobic and superhydrophobic surfaces, revealing that superhydrophobic surfaces do not always offer the best drag reduction performance. The application of the fractal model to practical topographies of nonwetting surfaces of copper, aluminum, and zinc oxide fabricated via electrodeposition and etching is also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗